background image

Summary of Contents for JGC7530BP0

Page 1: ... DE CABLAGE 19 COOKTOP SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word...

Page 2: ...r WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may cause ...

Page 3: ... openings in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and El...

Page 4: ...shortened to avoid interfering with the regulator and power cord Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock IMPORTANT The cooktop must be electrically grounded in accordance with local codes and ordinances or in the absence...

Page 5: ...as Conversion instructions provided in the package containing the literature The model serial rating plate located on the underside of the burner box has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP Gas conversion Conversion must be done by a qualified service technician No attempt shall be...

Page 6: ...ss steel gas supply line connector can be assembled to the cooktop now or after the cooktop is installed in the cutout See Make Gas Connection section 1 Using two or more people place the cooktop upside down on a covered surface 2 Remove foam strip from hardware package Remove backing from foam strip Apply foam strip with adhesive side to the countertop within 1Ae 1 6 mm from the edge of the cutou...

Page 7: ...dapters see B and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters 3 Use a 15Ae combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked A _ H _ E F G 2 NOTE When installing the cooktop above a built in oven install a 90 elbow 1 ...

Page 8: ...on cord Failure to follow these instructions can result in death fire or electrical shock 3 Plug into a grounded 3 prong outlet Electronic Ignition System Check Operation of Surface Burners 1 Push in and turn the surface burner control knobs to the HI position The surface burner flame should light within 4 seconds The first time a surface burner is lit it may take longer that 4 seconds to light be...

Page 9: ...__ klnliPlug Line wide blade Ground___ _ _ _ F Round blade T_I Ground Plug 1 Receptacle1 w RF W Electrodes Spark Modules 14 15 Pilot Lights LR BK RR BK C BK LF C RF LF BK RE Valve Switches NOTE Electric circuit is closed when knob is pushed in and rotated from 0 to 210 counterclockwise from Off ...

Page 10: ..._ co PowerCord Neutral Plug bade_ N G _ wide Ground _ Line wide blade _Y Roundblade _ I W 1 W BK BK w R 0 RR BK _ g v BK r n OF IK __ Valve Switches RF OF RF NOTE Electric circuit is closed when knob is pushed in and rotated from 0 to 210 counterclockwise from Off 10 ...

Page 11: ... Si les renseignements dans ce manuel ne sont pas exactement observes un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un deces Ne pas entreposer ni utiliser de I essence ou d autres vapeurs ou liquides inflammables proximite de cet appareil ou de tout autre appareil electromenager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appare...

Page 12: ...en vigueur Ne pas obstruer le flux de combustion et la ventilation C est I installateur qu incombe la responsabilite de respecter les distances de separation exigees specifiees sur la plaque signaletique de I appareil La plaque signaletique des numeros de modele et de serie est situee sur la face inferieure de la boite de brQleur de la table de cuisson viter I installation de placards de rangement...

Page 13: ... travail B Placard C 36 91 4 cm D Profondeur maximum recommand e des placards muraux 13 33 cm E 6 15 2 cm de d gagement minimum de la paroi lat rale F D gagement minimum de 30 76 2 cm entre le sommet de la plate forme de la table de cuisson et le fond du placard de bois ou de m tal non couvert D gagement de s paration de 24 61 cm ou plus Iorsque le fond d un placard de bois ou de m_tal est couvert...

Page 14: ...emas de c blage Risque d explosion Utiiiser une canalisation neuve d arriv_e de gaz approuv_e par la CSA international installer un robinet d arr6to Bien setter chaque organe de connexion de la canaiisation de gaz En cas de connexion au gaz propane demander a une personne quaifi_e de s assurer que la pression de gaz ne d_passe pas 36 crn 14 po de Ja colonne d eau Par personne qualifi6e on cornpren...

Page 15: ...robinet d arret manuel Le robinet d arret manuel est prevu pour ouvrir ou fermer I alimentation en gaz de la table de cuisson A B A Canalisation de gaz B Robinet d arr t manuel position d ouverture C Vers table de cuisson D_tendeur Le detendeur fourni avec cette table de cuisson doit etre utilis La pression d alimentation du detendeur doit etre comme suit pour un fonctionnement correct Gaz naturel...

Page 16: ... de la table de cuisson des debris et I aide reposer a plat sur des plans de travail irreguliers C D A Plan de travail C Ouverture B Bande de mousse D _ 1 6 mm Installer le regulateur sur la table de cuisson avant de monter cette derniere dans le placard Voir la section Raccordement au gaz Table de cuisson sur four encastr_ sous comptoir IMPORTANT Ne pas utiliser de brides de fixation 1 Installer ...

Page 17: ...a table de cuisson et sur I extremite male du raccord coude 90 Utiliser uniquement un compose d etancheite des tuyauteries con _upour I utilisation avec le gaz naturel ou le propane Ne pas utiliser de ruban TEFLON II sera necessaire de choisir les raccords a utiliser en fonction de la configuration d installation Raccordement typique par raccord flexible 1 Appliquer un compose d etancheite des fil...

Page 18: ...e de rallonge Le non respect de ces instructions peut causer un d_c_s un incendie ou un choc _lectrique 3 Brancher sur une prise a 3 alveoles reliee a la terre Systime d allumage ilectronique Contr61e du fonctionnement des br_leurs de surface 1 Enfoncer et tourner les boutons de commande de brQleur de surface a la position HI eleve Le gaz dolt s enflammer sur le brQleur de surface en moins de 4 se...

Page 19: ...e Broche plate Terre l y Broche ronde _ L l Terre Fiche 1 R eptacle 1 BL AvD AvG Electrodes Modules d allumage o_ 1 14 1 15 ArG ArG ArG N ArD N 0 c N 0 AvG N N 0 AvD Contacteurs du robinet REMARQUE Le circuit electrique est ferme des que le bouton est enfonce et tourne dans le sens anti horaire entre 0 et 210 depuis la position d arr_t 19 ...

Page 20: ...co N n 18 14 15 N N ArG ArG N ArC C ArD N C AvG N C AvC AvD I ArG ArD AvD Contacteursdu robinet REMARQUE Le circuit electrique est ferme des que le bouton est enfonce et tourne dans le sens anti horaire entre 0 et 210 depuis la position d arr6t W10588275B M fr 2013 Jenn Air Used under license in Canada All rights reserved Utilise sous licence au Canada Tous droits reserves 7 13 Printed in U_S A Im...

Reviews: