background image

User Guide for 86008

Generator

12,000 Watt, Rated 9,500 Watt Dual-Fuel

Summary of Contents for 86008

Page 1: ...User Guide for 86008 Generator 12 000 Watt Rated 9 500 Watt Dual Fuel ...

Page 2: ...nics 13 How to Stop Engine 13 Receptacles Extension Cords 14 Extension Cord Selection 15 Moving the Generator 15 Do Not Overload Generator 15 Wattage Reference Guide 16 Hour Meter 17 Power Management 17 How to Charge a Battery 17 Cold Weather Operation 17 Maintenance 18 21 Maintenance Schedule 18 High Altitude Operation 18 Checking Spark Plug 19 Changing Oil 19 How to Clean Air Filter 20 Checking ...

Page 3: ... 30 Amp Receptacle Fuel Tank 120V NEMA 5 Receptacle Generator Frame Tank Vapor Valve Choke Lever Fuel Gauge Fuel Valve On Off Recoil Handle Air Filter Housing Handle Grip Support Leg Oil Drain Plug Oil Fill Dipstick Never Flat Foam Filled Wheels 6 7 8 9 15 16 17 18 19 20 21 22 10 3 4 5 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Page 4: ...tem for this generator is compliant with all standards set by the US EPA 555 86008 Source Gas LPG Rated Wattage Rated Voltage Rated Frequency Rated Ampere Rated Output Max Output Displacement Engine Type Oil Type Oil Capacity Fuel Capacity Fuel Type AC Output Engine 9500W 8550W 120V 240V Both 60Hz Both 79A 71 25A 9 5kVA 8 55kVA 12kVA 10 8kVA 457cc Single Cylinder 4 Stroke OHV Air Cooled SAE 10w30 ...

Page 5: ...d for carbon monoxide protection The engine exhaust contains chemicals that can cause cancer and birth defects To reduce the risk of serious injury use caution when lifting the generator Never exceed the generator s wattage amperage capacity This may damage the generator and or connected devices Never start or stop the engine with electrical devices plugged into the receptacles Failure to do so co...

Page 6: ...nit Only operate the generator on a level surface If connected to a structure connect the ground terminal to an appropriate ground This generator produces high voltage which may result in burns electrocution causing serious injury or death Never handle the generator electrical devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Nev...

Page 7: ... or make adjustments to this unit while it is running Never insert objects into cooling slots Never operate this unit if there are any broken or missing parts Improper treatment of this generator can shorten it s life Always repair this unit as specified in this manual Shut generator off if electrical output is missing unit vibrates excessively or begins to smoke spark or emit flames Safety Rules ...

Page 8: ... 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Generator Operator s Manual Spark Plug Wrench Combination Wrench Funnel Handles Bushings Flanged One Stage Regulator Wheels Axles Hair Pins Screws Washers Supporting Legs Nuts Measuring Cup Qty 1 1 1 1 1 2 4 1 2 2 2 2 2 2 2...

Page 9: ...ated on the side of the frame 3 Secure the wheel assembly by reinserting a cotter pin through hole at the end of the wheel axle and pressing until it locks into place 4 Repeat process on the other side of the generator to install the second wheel Figure 2 Installing the Support Legs Figure 3 1 Parts needed 2 Support legs 4 M8 screws 4 M8 nuts 2 Raise the front end of the generator high enough to g...

Page 10: ... battery for replacement Remove the nut and bolt first from the negative Black post then from the positive Red post being careful not to short across the terminals Always abide by the safety warnings provided with the battery Remove the battery and dispose of it according to your local and state regulations Antidotes for Battery Acid Contact External Internal Eyes Treatment Flush with water Drink ...

Page 11: ...10W 30 to empty crankcase until oil reaches the outer edge of the oil fill hole crankcase dipstick hole 3 Be sure to replace dipstick before attempting to start the engine 4 To check oil set generator on a level surface wipe dipstick clean then reinsert dipstick without rethreading Figure 5 Figure 6 Adding Fuel Figure 6 1 Set the generator outdoors away from windows and doors 2 Remove fuel cap 3 I...

Page 12: ...t are wet Always keep the generator dry Never operate Do not overfill the fuel tank Provide space for fuel expansion generator in rain or under wet conditions Use a ground fault circuit interrupter GFCI in a damp or highly conductive area such as metal decking or steel work Never plug electronic devices into generator having frayed worn or bare wires Never touch bare wires or make contact with rec...

Page 13: ... or hot For electric start Push and hold the engine Start switch in the Start position Do not hold the Start switch in the Start position for more than 15 seconds Allow 1 minute between starting attempts fig 12 For manual start turn the engine Start switch to the On position Pull the recoil starter grip slowly until resistance is felt then pull rapidly See fig 12 Let engine run for several seconds...

Page 14: ... gasoline Turn the engine Start switch to the Off position fig 16 Turn the fuel valve lever to the Off position fig 14 When using LPG Turn the engine Start switch to the Off position fig 16 Close valve on LPG bottle fig 15 Pull cord recoils quickly and could result in injury To avoid recoil pull the starter cord slowly until resistance is felt then pull rapidly for more than 15 seconds Allow 1 min...

Page 15: ...Volt AC single phase 60Hz loads requiring up to 2400 watts 2 4 kW at 20 Amps Use extension cords having a minimum rating of 125 Volts AC 20 Amps 120 240 Volt AC 30 Amp locking receptacle This receptacle has a 30 Amp push to reset circuit breaker to protect against overload This receptacle is rated to operate 120 Volt AC single phase 60Hz loads requiring up to 3600 watts 3 6 kW at 30 Amps It is als...

Page 16: ...eavyandrequiresatleasttwo people to lift Lift and lower with your legs not your back to avoid injury This is done by bending at the knees not your back Don t Overload the Generator Make sure you can supply enough rated watts and surge watts for all electrical devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the ...

Page 17: ...er Bathroom Hair Dryer Curling Iron Family Room X Box or PlayStation AM FM Radio DVD TV or Monitor 40 in Home Office Fax Machine Computer Printer Copy Machine Power Tools 1000W Work Light Airless Sprayer 1 3 hp Reciprocating Saw Circular Saw 7 1 2 in Miter Saw 10 in Table Radial Arm Saw Electric Drill 5 4 Amps Hammer Drill Air Compressor Rated Watts 1500 1500 3500 4000 1200 1150 700 5400 1250 1000...

Page 18: ...8 This generator can be used to charge a 12 volt automotive storage batteries with the following steps Inspect fluid level of the battery cells Add ONLY distilled water to any cell where fluid level is low Never add tap water Use a wire brush to clean the battery terminals if they are corroded Connect the Battery Charging Cable to the 12 Volt DC posts Connect the red cable clamp to the positive ba...

Page 19: ...cing this machine make sure the engine is off and no parts are moving Disconnect the spark plug wire and move it away from the spark plug After 8 Hours or Daily After first 5 Hours Annually 25 hr Usage Annually 100 hr Usage Clean debris from generator and air filter area Change engine oil Check engine oil level Check and clean air filter Change engine oil after the first 25 hours again at 50 hours...

Page 20: ...nnually BOSCH F7TC NGK BP6ES CHAMPION N9YC or equivalent Changing Oil Run the generator until the engine is warm then shut OFF Place generator on a firm and level surface raised on blocks for easier access Remove the crankcase dipstick Place an oil pan underneath the oil drain hole to collect used oil Remove the oil drain plug and allow oil to drain completely Reinstall oil drain plug tighten secu...

Page 21: ... Replace if necessary Use a brush to remove carbon deposits from the spark arrestor screen as needed To remove the spark arrestor When cool loosen the locking clamp Slide the spark arrestor out of the muffler Reverse this process to install it Figure 20 Replacing Fuel Filter Figure 21 Occasionally the fuel filter may become clogged and need replacing Turn the fuel valve to the Off position Remove ...

Page 22: ...securely on petcock Draining the Carburetor Turn the fuel valve to the Off position Turn the engine Off Positionasuitablecontainerunderthecarburetor drain screw to catch fuel loosen and remove the screw Allow fuel to drain completely into container be sure to wipe up any spilled fuel right away Re tighten drain screw taking care that the gasket seal is in place Creating a Temporary Cold Weather Sh...

Page 23: ...l Storeindoorstopreventfreezingofunitandusea protective cover to protect from dust The generator must be shipped run and stored in the upright position Engine Long Term Storage Remove the spark plug and pour about 1 teaspoon of 10W30 engine oil into the spark plug hole Reinstall the spark plug Turn fuel valve knob to the Off position pull the recoil starter cord several times to coat the cylinder ...

Page 24: ...15 3 Clean or replace fuel filter 4 Contact tech sales 5 See above solution 4 1 On Off switch set to OFF 2 Dirty air filter 3 Clogged fuel filter 4 Out of fuel or stale fuel 5 Spark plug wire disconnected from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel knob on Off position 9 Low oil level 10 Engine has flooded 1 Turn switch to On 2 Clean or replace Air filter 3 Clean or replace fuel filter...

Page 25: ...Wiring Diagram 24 ...

Reviews: