background image

Vesta C led

Vesta A large | VSTAL

Ø 6~12

Ghisamestieri the green way of light s.r.l. • Azienda certific ta  ISO 9001:2008 • phone +39 0543 462611 • fax. +39 0543 449111 • [email protected] • www.ghisamestieri.it      

Instruction manual

Operation and maintenance manual

1. Pre installatin checks

2. Mark fac-simile

Verify the product integrity and the compatibility of the 

technical data in the mark placed on the product with the 

plant.

If there aree incompatibilities do nothing and contact the 

company.

Symbols key (if any)

 Version

CE mark

Insulation class II

(not present in class I)

Waste disposal

Not attaching the light source 

according to the photobiological 

safety

Brand safety

Pic. 1

Available versions

Timeless

Regenerable luminaire with

replaceable LEDs and drivers

without tools.

Geometric features

Height

319 mm

Widht

547 mm

Lenght

547 mm

Weight

10 kg (wiring excluded)

Exposed area

Lateral: 0,05 m² | Pianta: 0,20 m ²

Electrical features

PF

> 0.90

I

max

- I

min

700 mA - 200 mA

Installation features

Work environment

Outdoor

Assembly position

Horizontal

Maximum environment temperature

40°C

Mounting height

< 15 m

Hygroscopic moisture

0 – 100 %

Degree of protection

IP 66

collection: lightecture | up date: 2017.02

WARNING | 

Read this manual carefully and store it in a safe 

place for further use.

Set up must be carried out by specialized 

technicians only.

Installation

The lantern is suitable for installation on wire system, final diameter 

of the cable Ø6-12 (Pictures 1).

JCL LIGHTING - 70 rue Louis Armand - ZI Les Milles - BP 144 - 13794 Aix-en-Provence Cedex 3 (France) - 
Tél : 04-42-24-42-41 - Fax : 04-42-39-73-55 - [email protected] - www.jcllighting.com 

Summary of Contents for Vesta A large

Page 1: ...res Height 319 mm Widht 547 mm Lenght 547 mm Weight 10 kg wiring excluded Exposed area Lateral 0 05 m Pianta 0 20 m Electrical features PF 0 90 Imax Imin 700 mA 200 mA Installation features Work environment Outdoor Assembly position Horizontal Maximum environment temperature 40 C Mounting height 15 m Hygroscopic moisture 0 100 Degree of protection IP 66 collection lightecture up date 2017 02 WARNI...

Page 2: ...ure the safety cord around a tensioned cable and lock it with spring hook Insert the locking clamp in the wire system accessory Lock the lighting fixture through the tightening of the M6 screw coupling torque 5Nm Tighten the nuts for device locking If you need to back tilt Insert the cable into PG16 in the wire system accessory and introduce it inside the luminaire Open the lighting fixture as sho...

Page 3: ... extraction using the Red knobs in Figure 2 loosen the bracket door modules Remove the bracket and pull out the modules LED module LED module placement place the bracket in the slot When in position tighten the plate with red knobs are visible in Picture 2 Inserting driver door driver door bracket place the bracket in position and secure it by tightening the knob nall Allen red in Figure 1 Connect...

Page 4: ...carried out by the manufacturer by its care service or by specialized technicians only At the end of the useful life of the electrical products and or components do not dispose the product with urban waste Take it to the special municipal separate collection points 4 3 Compliant packaging pusuant to CE Directive 94 62 100 fibrocartaceo material 100 recyclable and biodegradable Recyclable material ...

Reviews: