Page 1: ...VPP T2100 Emergency Assistance Telephone Installation and Operation Manual VPP T2100 45005 Rev 1 12 22 N56 W24720 N Corporate Circle Sussex WI 53089 800 527 9156 www januselevator com...

Page 2: ...g Calls 3 PROGRAMMING 3 1 How to Program the Phone 3 2 Program Code Formats 3 3 Recording Voice Messages 3 4 Example Programming 3 5 Additional Programming Functions 3 6 Index of Program Codes 3 7 Fac...

Page 3: ...t The input is 115 VAC and the isolated output is about 13 Volts DC When powering the T2100 from a remote DC source consideration must be made for the resistive line drop of the wire used The T2100 wi...

Page 4: ...in steps of 1 9 Increases speaker volume in steps of 1 8 Decreases Microphone volume in steps of 1 9 Increases Microphone volume in steps of 1 0 Will repeat the voice message Will hang up Note Comman...

Page 5: ...activate the speaker in this mode The T2100 will hang up in response to any of the conditions that terminate an outgoing call Programming Mode Press 2 followed by the programming password and The T21...

Page 6: ...the program code the feature is selected or in some cases disabled Other entries require the two or three digit program code to be followed by a string of digits and by a pound sign For example to se...

Page 7: ...ch like leaving a message on an answering machine you speak after a beep The difference is that you can set the length of the message by entering 1 after you have spoken If you don t do this the phone...

Page 8: ...ximately 18 seconds to 60 seconds 44 Enable Auxiliary Output 1 on outgoing calls factory default setting This program code sets the phone so that Aux Out 1 closes when the phone is activated by pressi...

Page 9: ...ng you to get into the converse or silent monitor mode by entering only a 1 or 4 respectively 63 number Set maximum conversation time factory default setting is 10 minutes The number you program sets...

Page 10: ...e first CPC pulse to occur before a call is answered is ignored 84 Disable CPC detection altogether This mode is normally only used when it is necessary to troubleshoot an installation 89 time Ring ba...

Page 11: ...Check if unit is pulling down line voltage you should read the same as the phone line voltage Open the back box of the unit unplug the button connector and try shorting button connection at J10 pins I...

Page 12: ...e that may cause undesired operation On this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipment If requested th...

Page 13: ...tivities in the off peak hours such as early morning or late evenings The mounting of the approved unit in the final assembly must be made so that the approved unit is isolated from exposure to any ha...