background image

AquaLink

®

 RS OneTouch

 

Control Systems

For use with 

AquaLink RS Systems

with Rev O.2 - T.1 Firmware

ENGLISH

6593_REV

N

OWNER’S MANUAL

 WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a contractor 
who is licensed and qualified in pool equipment by the jurisdiction in which the 
product will be installed, where such state or local requirements exist. In the event 
no such state or local requirement exists, the maintainer must be a professional with 
sufficient experience in pool equipment installation and maintenance, so that all of 
the instructions in this manual can be followed exactly. Before installing this product, 
read and follow all warning notices and instructions that accompany this product. 
Failure to follow warning notices and instructions may result in property damage, 
personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which 
can cause serious injury, property damage, or death.

Summary of Contents for AquaLink RS OneTouch Control Systems

Page 1: ...ment exists the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Befor...

Page 2: ...Page 2 ENGLISH AquaLink RS OneTouch Owner s Manual...

Page 3: ...al Equipment 20 4 3 3 Variable Speed Pump 21 4 3 3 A Variable Speed Pump Setup 21 4 3 3 B Pump Model 21 4 3 3 C Pump Application 21 4 3 3 D Min Max Settings 22 4 3 3 E Speed Labels 22 4 3 3 E 1 Set Sp...

Page 4: ...Custom Labeling 43 5 2 2 Auto Switching 43 5 3 OneTouch 44 5 3 1 OneTouch Setup 44 Section 6 Glossaries 45 6 1 Safety Delays And Lockouts 45 6 2 Special Auxiliary Labels 46 6 3 Controller Messages 46...

Page 5: ...al temperature of the body The effects of hyperthermia include 1 unawareness of impending danger 2 failure to perceive heat 3 failure to recognize the need to exit spa 4 physical inability to exit spa...

Page 6: ...y of drowning Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa Persons using m...

Page 7: ...ith a no 8 AWG 8 4mm2 copper wire to any metal ladders water pipes or other metal within five 5 feet 1 52m of the pool spa In Canada the bonding wire must be minimum 6 AWG 13 3mm2 WARNING A ground fau...

Page 8: ...AIR 79 06 02 03 MON 6 00 PM EQUIPMENT ON OFF MENU HELP ONETOUCH ON OFF Main System Menu System Menu 2 System Menu 3 Up and Down Scroll Keys Scroll within current menu can be held for continuous scrol...

Page 9: ...aLink RS system is in service or time out mode will return the system to auto mode In previous firmware versions the system defaults to the last mode of operation SPA MODE ON CLEAN MODE OFF ALL OFF NE...

Page 10: ...ter custom information for your local or preferred service center JANDYAquaLinkRS 01 31 03 Mon 6 00 PM Equipment ON OFF Onetouch ON OFF Menu Help 79 F Air Filter Pump OFF Menu Help Program Set Time Se...

Page 11: ...es for daylight savings Daylight Saving Time in the United States begins at 2 00 a m on the second Sunday of March and ends at 2 00 a m on the first Sunday of November For details please visit www nis...

Page 12: ...s water levelling and sprinkler system programs based on the seasons when outdoor temperatures and daylight hours typically change 12 00 AM System Setup In Floor Clean Solar Priority Pump Lockout Assi...

Page 13: ...4 2 Set Temp 3 5 2 TEMP CALIBRATE SYSTEM SETUP MENU HELP Select to adjust the temperature displayed on the AquaLink RS system Temperature can only be adjusted by 4 F up or down and should be made for...

Page 14: ...tect equipment and plumbing for short periods of freezing only It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing Freeze protection...

Page 15: ...RS operations When LOCK is displayed any changes to programs or system setup features are prevented When SpaLink and Spa Switch display LOCK all controls for both systems are deactivated Devices disp...

Page 16: ...he systems programs or devices do not require Lockouts to be set Menu Help Program Set Temp Set Time Display Light Lockouts Program Group System Setup Password Enter Password 1 2 3 4 Use ARROW KEYS to...

Page 17: ...at has been turned on manually or by a program This includes heater enables that were on unless in use by the Maintain function System Setup Solar Priority Assign Jvas Dimmers Color Wheels Spa Switch...

Page 18: ...n pump on and off Circulates the pool or spa water through the filter and heater Will activate if the spa pool cleaner or spa spill over are activated Must be on to display the pool temperature or to...

Page 19: ...IPMENT EQUIPMENT ON OFF Select to turn the main filtration pump on and off For dual equipment configurations additional equipment options will be available and both the filter pump and spa pump can op...

Page 20: ...th a start time earlier than the current time will execute on the following programmed day 4 3 2 c SPA DUAL EQUIPMENT EQUIPMENT ON OFF Select to turn spa pump on For dual equipment configurations addi...

Page 21: ...t to set pump application Up to 4 variable speed pumps can be controlled and assigned a specific application based on equipment installed see table below The default setting is NOT INSTALLED The pump...

Page 22: ...r Pool Spa only Default Pool Spa Only Pool Spa Combo 1 POOL POOL 2 SPEED 2 SPA 3 SPEED 3 SPEED 3 4 SPEED 4 SPEED 4 5 TEMP 1 POOL HEAT 6 TEMP 2 SPA HEAT 7 SPEED 7 SPEED 7 8 INFLOOR INFLOOR CLEANER will...

Page 23: ...endent auxiliaries AUX When the auxiliary is activated the pump will run at the assigned speed If more than one auxiliary AUX is turned on with an assigned speed the default will be for the pump to ru...

Page 24: ...k RS 2 6 operates similarly to Pool Spa Only Low speed is enabled for the spa pump only To run pool pump at low speed an auxiliary must be assigned 4 3 4 d TWO SPEED PROGRAMMING ALL UNITS Programming...

Page 25: ...HELP Select to ENABLE or DISABLE the automatic in floor cleaning feature When enabled the AquaLink RS system rotates the in floor Jandy Valve Actuators JVAs every 20 minutes Filter Pump OFF Pool Heat...

Page 26: ...IN The system will periodically activate the pump sample water temperature and operate the heater to maintain the preset temperature Heater must be enabled for this feature to run effectively See Sect...

Page 27: ...her the thermostat temperature is reached or solar heat is no longer available If solar panel is not hot enough solar heat will shut off and other heat source normally gas heater will take over to bri...

Page 28: ...OLAR HEAT HEAT PUMP CHILLER and or EXTRA AUX simultaneously without RS485 control With RS485 Control SOLAR HEAT and HEAT PUMP CHILLER functions can be maintained and operated simultaneously Filter pum...

Page 29: ...ater are enabled solar will heat the water until either the thermostat temperature is reached or solar heat is no longer available If solar panel is not hot enough solar heat will shut off and other h...

Page 30: ...e the default when turning on a pool or spa light manually through the OneTouch control panel or a program Press the Back key to accept the last selected light color After 15 seconds without pressing...

Page 31: ...ulse control After 15 seconds without pressing any keys the most recently selected LPC4 function will be accepted again IMPORTANT Do not activate this feature unless you are certain that a Laminar Pul...

Page 32: ...N OFF Select to access the SPRINKLERS sub menu Set up start and run time programming via Sprinklers Setup menu in the System Setup menu See Section 4 6 5 Programming Sprinkler System for more details...

Page 33: ...state 4 6 1 CANCEL TODAY SPRINKLERS EQUIPMENT ON OFF Select to set a 24 hour delay of the sprinkler system This feature may also be used to quickly turn off all sprinkler valves 4 6 2 MANUAL START SPR...

Page 34: ...ON OFF menu Up to three 3 programs can be scheduled with different run days start times and durations Sprinklers Aux5 OFF OFF OFF OFF OFF OFF OFF Aux6 Aux5 Extra Aux Sprinklers Spa Mode Pool Heat Can...

Page 35: ...are activated in numerical order for the set duration time There is a 1 2 second delay between valve activations START 8 00AM Sprinkler Setup Highlight an item and press SELECT Program 2 ON Start 9 3...

Page 36: ...ssing CONTINUE with start times of each program for review Press EDIT to continue programming and press DONE to return to the SPRINKLER SETUP screen 4 7 CONTROLS 4 7 1 RS INTERLINK PWR CTR B EQUIPMENT...

Page 37: ...1 and AUX 2 After completing one equipment assignment the previous menu will appear to continue the process A label pack is provided to label the buttons on the switch RS Interlink Setup Custom Label...

Page 38: ...he previous menu will appear to continue the process A label pack is provided to label the buttons on the switch System Setup Solar Priority Assign JVAs Dimmers Spa Switch Spa Link Service Info Clear...

Page 39: ...ered AQUAPURE ADJUST will set the AquaPure output for both pool and spa while the pool is covered Disable Devices Cover Closed Aux1 Aux2 Aux3 Aux4 Aux5 Aux6 Aux7 Cover pools Setup When Cover Is Closed...

Page 40: ...luding iAquaLink but can only be set up from the OneTouch control panel Assign Jvas Intake Return Cleaner Solar Used Used Free Used System Setup Solar Priority Assign JVAs Dimmers Color Wheels Spa Swi...

Page 41: ...he manual operation of the filter pump Boost is not available in Spa mode WARNING The AquaLink RS is compatible with only Jandy AquaPure Jandy PureLink amd Clormatic branded Electronic Chlorine Genera...

Page 42: ...be set for all days weekends weekdays or specific days of the week Each piece of equipment can be programmed for multiple on off times each day Programs can be added deleted or changed as needed Prog...

Page 43: ...AUTO SWITCHING PROGRAM GROUP MENU HELP Select to automate the switching of the operation of GROUP A or GROUP B on specific dates MENU Help Program Set Temp Set Time Display Light Lockouts Program Grou...

Page 44: ...acters 1 IntelliFlo and IntelliPro are registered trademarks of Pentair Pool Products Inc 2 SAm SAL is a registered trademark of Pentair Pool Products Inc 3 Color Logic is a registered trademark of Ha...

Page 45: ...er Short Cycling Prevention When the heater is activated and the desired temperature is reached heater will turn off and remain off for 3 minutes even if the temperature falls below the desired temper...

Page 46: ...DIPSwitch ON the spareAuxiliary socket is energized in the Spa Mode and off in the Pool Mode Operates only with Pool Spa combination units 6 3 CONTROLLER MESSAGES CLEANER CANNOT BE TURNED ON WHILE SPA...

Page 47: ...s not operational Service mode is used by the pool service person to aid them in servicing the pool The Controller will not be functional until the switch at the Power Center is moved back to AUTO mod...

Page 48: ...HEAT SPA HEAT CHILL HOURS MODEL SENSORS REMOTES ADD PROGRAM DELETE CHANGE ERRORS EQUIPMENT EQUIPMENT MODE DIAGNOSTICS OFF POOL SPA MAINTAIN EQUIPMENT HELP PROGRAM SYSTEM SPA SWITCH SPA LINK DEVICES SY...

Page 49: ...MP APPLICATION SELECT PUMP SCALE MIN MAX SELECT PUMP SPEED LABELS SET SPEED SELECT A DURATION VALUE SET DURATION SELECT PUMP PRIME DUSK SETUP PROGRAM 1 PROGRAM 2 PROGRAM 3 SPRINKLERS ENABLED DISABLED...

Page 50: ...Page 50 ENGLISH AquaLink RS OneTouch Owner s Manual NOTES...

Page 51: ...AquaLink RS OneTouch Owner s Manual Page 51 ENGLISH NOTES...

Page 52: ...00 822 7933 www ZodiacPoolSystems com Zodiac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com DATE OF INSTALLATION _________________________________________ I...

Reviews: