TP-82N wireless indoor thermostat  

 

The TP-82N is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 
thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 
low temperature limits. 

 

 

Figure1

: 1- knob (encoder) combined with button 2- tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a  place where there  is good natural  air 
circulation.    Don´t install the thermostat where the measuring can be 
influenced by drafts, sunlight, heaters or any other effects.  Avoid  mounting 
the thermostat on metal objects  or metal bases which block radio 
communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 
it first. Open the enrollment mode on the receiver (see its manual) and insert 
the batteries into the thermostat or press and hold the knob for 5s. In both 
cases the thermostat will send an enrollment signal. 

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat;

 

3 – Alarm temperature-limits / Loss of communication;  

4 – Heating ON / OFF; 5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and  the changes are saved. Then the  thermostat goes to the 
next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 
menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1. 

LOc – Locking the thermostat 

To protect the 

thermostat against unwanted 

manipulation you can lock the thermostat.  Enter the 
menu and press the knob on item 

LOc

,  the  options 

ON/OFF 

appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 enables the function 

Lock

,  and  blocks  thermostat control.  To unlock the thermostat choose the 

option 

OFF. 

Locking the thermostat is indicated on the LCD by the 

 

symbol. 

2. 

 OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 
t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3. 

SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it 

is not necessary to change those parameters. The  Service  menu  includes 
8 items. Open by scrolling the knob to the requested item and by pressing the 
knob enter the programming mode. Select the value  again by scrolling the 
knob. Confirm it by pressing the knob and it returns you back to the service 
menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 
temperature (hysteresis). The range  can  be set with 
a 0.1°C step from 0.1°C to 1°C.  
(Default setting 0.2°C) 

Example: 

With  a  set accuracy  of  0.

5˚C  a  temperature  of 24°C  will be kept  this 

way, at 23.5°C it starts heating and at 24.0°C it stops heating. In real conditions 
regulation could have a much bigger temperature scatter because of the thermal 
inertia in the heated premises.  

Warning:  An over-narrow  pre-programmed hysteresis range  could  

perform on/off switching of the heating very often. 

 

 

The item 

Stby 

sets  the temperature which will be 

kept  in  the  case of switching off  the thermostat 
(item 

OFF

).  The 

Stby

  temperature  is always at least  

3°C higher than 

ALLo.

  The value of  the 

Stby

 

temperature does not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 
thermostat sends an alarm report to the receiver and 
this state is indicated by a permanently lit (

!

) symbol. 

The 

ALLo

  temperature  is always at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 
thermostat sends an alarm report to the receiver and 
this state is indicated by a permanently lit (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

  After you enter the  menu and press the knob 

on the 

RES

  item 

ON/OFF

  appears.  By scrolling the 

knob select 

ON,

 and press the knob. Then a RESET 

will be done.

 

When  the  reset is finished, a  20°C 

temperature is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the 

basic thermostat menu. 