INSTALLATION & OPERATION MANUAL FOR 

Hotplates 

 

 

 

MODEL 

MLS 

VHP212 ML-135AHP-12 

VHP424 ML-135AHP-24 

VHP636 ML-135AHP-36 

VHP848 ML-135AHP-48 

www.vulcanhart.com 

 

 
 

 

 

MODELS  MLS 

AHP212 ML-135AHP-12 

AHP424 ML-135AHP-24 

AHP636 ML-135AHP-36 

AHP848 ML-135AHP-48 

www.wolfrange.com 

 

 

AHP424

 

Summary of Contents for VHP212 ML-135AHP-12

Page 1: ...TURE USE FORM F 36955 04 07 INSTALLATION OPERATION MANUAL FOR Hotplates MODEL MLS VHP212 ML 135AHP 12 VHP424 ML 135AHP 24 VHP636 ML 135AHP 36 VHP848 ML 135AHP 48 www vulcanhart com MODELS MLS AHP212 ML 135AHP 12 AHP424 ML 135AHP 24 AHP636 ML 135AHP 36 AHP848 ML 135AHP 48 www wolfrange com AHP424 ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...e with the specifications on the rating plate riveted to the right side of the unit in the upper front corner If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the hotplate a...

Page 4: ... a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the hotplate without depending on the connector and the quick disconnect...

Page 5: ...d psig 3 45 kPa the appliance and its individual shutoff valve must be disconnected from the gas supply piping system When test pressures are psig 3 45 kPa or less the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the system WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE S...

Page 6: ...ng compound overnight In the morning rinse with hot water to remove any residues of cleaning compound Burner ports and burner rest should be thoroughly cleaned Venturi must be free from grease and lint When cleaning do not insert a pick into the burner port holes soap and water will normally do the job Heavy spattering or spill over may require cleaning with a mild oven cleaner After cleaning rins...