1

Operation Manual

iRis   

  360°

Digital Video Recorder

Zoom: 1.0x Flip: N Integr:Standard       11.9             100%

Summary of Contents for Digital Video Recorder

Page 1: ...1 Operation Manual iRis 360 Digital Video Recorder Zoom 1 0x Flip N Integr Standard 11 9 100 ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ... and Adjusting the Objective 21 Putting the Side View Tip Adapter 21 Passing Turns 22 Retracting the Endoscope 23 Creating and saving Image Captures Choosing a Standard Setting 24 Inserting Text 25 Image Capture and Video Recording in Mode OFF 26 Image Capture and Video Recording in Mode ON 27 Comparative Measuring with the iRis 29 Playback of saved Images and Video Recordings 30 Optimising Camera...

Page 5: ...terials and lightning conditions often makes it difficult to get high quality images It is easy to adjust the iRis to your application to receive optimal inspection images even in extreme situations Always keep the Operation Manual with the iRis It contains all information for safe and efficient operation However should you have further questions feel free to contact our Service Team Preamble Onli...

Page 6: ...hed with tungsten This can lead to electric shock at contact with live parts Therefore the iRis is never to be used in or at objects under tension Caution Never look directly into the light emitting part of the iRis It can cause injuries of eyes Always switch off the Light Source before changing controlling or cleaning the objective or the distal end of the Videoscope Caution Use the iRis in dry e...

Page 7: ...lected separately and returned to environmentally compatible recycling Recycling Withdrawal of batteries pur suant to the Battery Policy According to the German Battery Policy BattV we are obliged to inform you about the rules and liabilities for disposal and withdrawal of used batteries and accumulators According to 7 German Battery Policy the end user is obli ged to return used batteries and acc...

Page 8: ...nd in this manual on page 42ff in our accessories catalogue or on our homepage www itcworld de We are certainly pleased being at your disposal for personal consulting as well Scope of Delivery Online Store store itcworld de Rechargeable Battery in device when delivered Charger Lens Box Operation Manual Neck Holder ITC Case Pocket Zoom 1 0x Flip N Integr Standard 11 9 100 ...

Page 9: ...f the probe in the desired position during inspections The articulation can be moved in four directions up down and left right which really facilitates passing multiple co vings System Presentation Edge Protector 3 5 TFT VGA Colour Display Pins for Neck Holder Lever up down SD Card Slot under Edge Protector Control Panel integrated LED Light Source Lever left right Online Store store itcworld de Z...

Page 10: ...eizing The sheathing of the insertion tube is made of tungsten netting and particular increases the durability of the flexible probe The inspection area can be illuminated with the integrated LED Light Source ON OFF LED Light Source 12V DC Plug Cinch OUT for Hard Disk Monitor etc Handle Battery Compartment Swivel Lock Mechanism Capture Button Online Store store itcworld de ...

Page 11: ... Switching on or off the device OK BUTTON Confirming action Image capture ARROW KEYS Navigate up down Zoom in and out ARROW KEYS Navigate left right Adjusting brightness MENU Open Close on screen menu MEMORY Open Close Memory Mode RECORD CANCEL In Live Mode Start Stop video recording In Memory Mode Quit submenu FREEZE CAPTURE Pause video recording Freeze image Image capture ...

Page 12: ...place it in the charger Charging process is finished when charge indicator lamp conti nuously glows green Caution Only use the delivered charger to charge the battery Otherwise there is high risk of damages to the cells The operating voltage is shown in the status indicator line on the iRis display The fully charged battery is placed in the device when delivered Battery Compartment Cover Battery C...

Page 13: ...AC Adapter Power Supply Cable Item Nr 820 00001 003 V 2 PowerBelt Item Nr 900 06000 0030 V 3 Car Battery Cable Item Nr 900 05000 0004 4 Cigarette Lighter Cable Item Nr 900 00002 0012 Note The 12V DC plug as well as the socket is marked with a red dot Assure that both red dots are visibly opposed when connecting the 12V DC plug to the iRis ...

Page 14: ...t edge protector and put a formatted SD Card 32GB max into the card slot The SD Card included in the scope of delivery is already inserted and properly formatted If the SD Card is not formatted you have to format it as described on page 17 Online Store store itcworld de ...

Page 15: ...ndicator Line At start up the iRis always is in Live Mode At the bottom of the display the status indicator line can be seen It shows the status of zoom image flip camera power supply and light intensity Switching on the LED The LED is switched on or off by a long push on the Light Source Button With short push the intensity of the LED can be adjusted in three steps Starting Inspection Zoom 1 0x F...

Page 16: ... change the language set proceed as follows MENU System Setting OK Select language the menu will immediately be shown in the selected language To quit press MENU again Starting Inspection Online Store store itcworld de Status Line ON Freeze Frame OFF Language English Date Time Press OK SD info Press OK SD format Press OK Fabric Settings Press OK Software Status P010 55 Serial Number 20110815 Langu...

Page 17: ...t SD and press OK A confirmation prompt appears on the display Select via arrow keys and confirm with OK Starting Inspection Image Control Camera Control Annotation Dimension System Setting Safety remove SD System Setting Status Line ON Freeze Frame OFF SD format Press OK Date Time Press OK SD info Press OK SD format Press OK Fabric Settings Press OK Software Status P010 55 Serial Number 20110815 ...

Page 18: ...g the arrow keys select menu item Date Time and press OK Set the desired time and date via the arrow keys and then confirm by pressing OK Starting Inspection Online Store store itcworld de Image Control Camera Control Annotation Dimension System Setting Safety remove SD System Setting Status Line ON Freeze Frame OFF SD format Press OK Date Time Press OK SD info Press OK SD format Press OK Fabric S...

Page 19: ...MENU System Setting OK Fabric Settings OK You are in Live Mode again afterwards Starting Inspection Image Control Camera Control Annotation Dimension System Setting Safety remove SD System Setting Status Line ON Freeze Frame OFF Language English Date Time Press OK SD info Press OK SD format Press OK Fabric Settings Press OK Software Status P010 55 Serial Number 20110815 Fabric Settings Press OK ...

Page 20: ...eter to default set ting Using the MENU button will bring you back to Live Mode Caution The image parameter are effective to the image displayed as well as to images and videos being saved Image captures and video recordings will be saved as displayed Starting Inspection Online Store store itcworld de Image Control Camera Control Annotation Dimension System Setting Safety remove SD Image Control B...

Page 21: ...ticulation The articulation section can be moved in two planes by means of the levers on the handle see fig If the levers are released during movement the articulation section will be locked in the current position On the image the levers are shown in neutral home position In this position the articulation section is straighten Starting Inspection Online Store store itcworld de ...

Page 22: ...mmended to adjust the objective to the re quired working distance before starting the inspec tion The working distance gets farther by turning the objective into the distal end Caution Never turn in the objective with force Mounting the Side View Tip Adapter If a lateral view is necessary e g in tubes or narrow cavities a 90 Side View Tip Adapter can optionally be mounted Depending on diameter of ...

Page 23: ...m occurs retract the probe carefully Fig A Carefully push the probe to the beginning of the coving while observing on the display Fig B Still observing on the display adapt the articula ting section to the coving of the cavity by using the levers Fig C and D Continue the insertion process while always ob serving on the display The angle of the articula ting section has to be adapted step by step t...

Page 24: ...void contacts of the distal end with the walls of the sur rounding At resistance during the retraction it is recommended to slightly twist the probe in both senses around its longitudinal axis and at the same time carefully push and pull until the probe is released again Caution Put both levers to neutral position as shown before retracting the scope Caution Put both levers to neutral position as ...

Page 25: ...press OK Using the arrow keys select Freeze Frame and choose ON or OFF Creating and saving Image Captures and Video Recordings Online Store store itcworld de Image Control Camera Control Annotation Dimension System Setting Safety remove SD System Setting Status Line ON Freeze Frame OFF Language English Date Time Press OK SD info Press OK SD format Press OK Fabric Settings Press OK Software Status ...

Page 26: ...ng the image Press MENU select menu item Annotation and press OK Use the arrow keys to select the desired charac ter and press OK To quit and save the text press RECORD to quit without saving press MENU You can delete single characters by pressing FREEZE Creating and saving Image Captures and Video Recordings Image Control Camera Control Annotation Dimension System Setting Safety remove SD Annotat...

Page 27: ... saving Image Captures and Video Recordings Direct Image Capture Start Stop Video Recording During recordings single images can be saved as follows Online Store store itcworld de Standard Setting Nr 1 Freeze Frame OFF ...

Page 28: ...ezes Frozen is displayed on the screen Image freezes Frozen is displayed on the screen Back to Live Mode Save Image Save Image 1 x short push Save Image Push 1 x 1 x long push Back to Live Mode 1 x short push 1 x long push Online Store store itcworld de Standard Setting Nr 2 Freeze Frame ON ...

Page 29: ...h 1 x Save image Press 1 x Save image 1 x short push Pause Continue recording Press 1 x Pause Continue recording 1 x short push Start recording Stop recording Press 1 x Online Store store itcworld de Text Optionally insert in advance see page 26 ...

Page 30: ... to the end of the geometry When both flags are on the desired positions press MENU twice choose Dimension and Calibration afterwards always confirming with OK Please insert the measure as value in front of the and the unit e g mm behind of it To save and quit Caibration press RECORD To quit without saving press MENU After having pressed RECORD the inserted unit appears in the display while being ...

Page 31: ...tion Folder Picture Video Format avi Resolution 800 x 600 pixel LOCATION Folder HVR Name All files image as well as video recording are named by the system Each image and video gets an automatically created file name consisting of date and time Playback of saved Images or Video Recordings Online Store store itcworld de 4 000 MM 2011 04 05 10 25 45 IT CONCEPTS INSPEKTION ...

Page 32: ...e LED Light Source is automatically swit ched off in Memory Mode and reactivated when changing to Live Mode again Playback of saved Images or Video Recordings BROWSER SD HVR 1 Folders 0 File 0KB HVR PICTURE BROWSER SD HVR File Browser HVR 0429 HVR 1 Folders 0 File 0KB 0430 BROWSER SD HVR 0430 File Browser HVR 11 HVR 1 Folders 0 File 0KB 10 Online Store store itcworld de ...

Page 33: ...essed the desired file you can con trol it as follows by using the arrow keys and the OK button OK Start Stop Pause video Left rewind Right Fast forward Cancel Quit Furthermore you may select additional functions through the context menu Playback of saved Images or Video Recordings BROWSER SD HVR 0430 10 File Browser T20111910172205 AVI 5MB HVR 1 Folders 0 File 0KB T20111910172301 AVI 5MB Icon Vie...

Page 34: ...EGRATION MANUAL INTEGRATION Press MENU select the menu item Camera Control and press OK Choose the desired camera setting by using the arrow keys Optimising Camera Settings Kameraeinstellung Standard Detector Type Mean Manual Shutter 50 Manual Gain 50 AGC Level 50 Gamma 2 White Balance Press OK Image Control Camera Control Annotation Dimension System Setting Safety remove SD Camera Control Integra...

Page 35: ...ce For optimal colour reproduction it is required to make a white balance 1 Place the distal end of the videoscope in front of a white non reflecting sheet of paper 2 Switch on the light source 3 Put the distal end in a position where no irradi ations are visible in the picture 4 Select the menu item White balance and hold the OK button until the white balance is carried out Gamma With Gamma the v...

Page 36: ...nal brightness based on the AGC level and the brightness measured Peak Detector The camera control system adjusts the image brightness depending on the brightest line detected Application Better perceptibility of details in image areas with high brightness AGC Level Auto Gain Control This features adjusts the optimal image brightness with the brightness ad justment level being predefined by the AG...

Page 37: ...AGC level and the brightness measured Peak Detector The camera control system adjusts the image brightness depending on the brightest line detected Application Better perceptibility of details in image areas with high brightness AGC Level Auto Gain Control This features adjusts the optimal image brightness with the brightness ad justment level being predefined by the AGC Value high value high gain...

Page 38: ...or This allows image capture at poor lighting conditions Manual gain Setting image brightness by adjusting the signal gain But this will increase electric signal noise and reduce image quality Gamma With Gamma the video signal is corrected regarding brightness and contrast Optimising Camera Settings Online Store store itcworld de Kameraeinstellung Standard Detector Type Mean Manual Shutter 50 Manu...

Page 39: ...tton cloth If necessary use mild detergent and dry carefully afterwards Do not clean display or housing under running water or immerse in liquids Cleaning the Probe Wipe off dust and dirt with a soft cotton cloth Wash the flexible part with a moist sponge Dry with a clean and soft cotton cloth after cleaning The distal end has to be cleaned with cotton swabs Q Tip soaked with high proof alcohol Do...

Page 40: ...g and move it from one extreme position to the other so that the articulation moves in an angle ca 160 to ca 130 in the vertical plane Then bring the lever back to the neutral position and release it Analogical move the lever R L so that the articulation moves in an angle of ca 100 in the horizontal plane Bring the lever back to the home position afterwards and release it At occurrence of any prob...

Page 41: ...robe too much Afterwards push the rest of the probe thoroughly into the reel until the probe is securely placed and cannot be damaged by the case or any accessories Avoid bending the probe to an arc radius less than 45mm In case of storing the system outside the transport case it should be hung at the housing The storing location should be protected against humidity direct sunlight and high temper...

Page 42: ...s Tool 930 00100 0002 V 6 0mm Side View Tip Adapter 1 5 2 90 60 5 0mm 15 0mm 930 00100 0003 V 6 0mm Side View Tip Adapter 1 5 2 90 90 7 0mm infinity 930 00200 0006 V 6 0mm Objective Lens RED 1 4 3 0 90 7 0mm infinity 930 00200 0007 V 6 0mm Objective Lens BLACK 1 5 2 0 90 7 0mm infinity 930 00200 0005 V 8 0mm Lens Tool 930 00100 0001 V 8 0mm Side View Tip Adapter 1 6 4 90 60 5 0mm infinity 930 0020...

Page 43: ...h French Spanish Italian German Video interface Composite Video out Power Supply primary changable Li Ion Battery Charger is provided Power Supply secondary 12V Adapter Measurement Method Comparative Measurement Function Documentation Video Format AVI avi Image Format BMP bmp Storage SD HC Memory Card up to 32GB FAT32 Camera Control Image Sensor High Resolution Color SUPER HADTM CCD Camera Control...

Page 44: ... Operating Temperature 14 F to 176 F 10 C to 80 C System Operating Temperature 13 F to 115 F 25 C to 45 C Storage Temperature 13 F to 115 F 25 C to 45 C Relative Humidity 95 max non condensing Waterproof Probe and distal end up to 14 7 psi 1 bar 10 2 m H2 O Hazardous Environments Not rated for use in hazardous environments Interchangeable Objective Lenses SVTA Probe DOV FOV DOF CODE ART NR 4 0mm 0...

Page 45: ... this product iRis 360 DVR Art Nr 900 03001 0002 complies with the following directive or normative documents EN61326 1 2006 Emission and Immunity according to directive 2004 108 EG Electromagnetic Compatibility see image Lahnau 2011 04 13 Online Store store itcworld de ...

Page 46: ...46 Notizen ...

Page 47: ...47 ...

Page 48: ...o change We reserve the right of making technical changes at any time No sections of this Operation Manual may be reprinted photo mechanically mechanically or digitally copied or reproduced without the express approval of IT Concepts GmbH IT Concepts GmbH Gewerbestr 17 D 35633 Lahnau Fon 49 6441 679299 0 Fax 49 6441 679299 99 www itcworld de info itcworld de Version itc iRis dvr operation manual o...