background image

 

 

MEASUREMENT AND ASSEMBLY MANUAL 

 

Validity of the manual: 21.3.2022 

PERGOLA  ARTOSI     

Measurement 

Always  take  measurements  of  the  outer  profiles  of  the  structure. 
We  enter  the  total 

width

 

[W],

  the  total 

length  [L]

  (marked  as 

height

  in  the  order  form)  and 

passage  height  (H)

  for  each 

individual pole. 

When  taking  the  measurements,  it  is  also  necessary  to  specify 
optional accessories such as lighting, rain sensor, etc. In the order 
form.  It  is  also  suitable  to  specify  construction  readiness  for  the 
subsequent  installation  of  the  whole  pergola  system  (anchor 
points,  water  outflow,  motor  placement,  electricity  connections,  integration  of  the  pergola  to  the 
house, etc.). When the pergola is mounted properly, slats dropping is made in direction from the motor to 
the other side. Water drainage has to be thus always on the opposite side of the motor. There always has to 
be at least one drainage groove in a pergola. 

Measurements will be described in detail for each variant of the pergola types. 

The supply includes a dimensional sketch of the actual order with electricity connections and water outflow 
points. 

Manipulation space is necessary for the installation 

 see the cross-hatched area (red) in the figures below. 

 

Variant A

 

              

 

 

 

 

 

 

 

 

 

 

 

 

 ISOTRA a.s. 

Bílovecká 2411/1, 746 01 Opava

 

19 

EN 13561:2015 

ARTOSI 

CPR 043/2019 

Exterior Sun Screen 

Wind resistance: 

6

 

Total solar energy transmission factor gtot: 

0,03 - 0,6 

Summary of Contents for ARTOSI

Page 1: ...ricity connections integration of the pergola to the house etc When the pergola is mounted properly slats dropping is made in direction from the motor to the other side Water drainage has to be thus a...

Page 2: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 2 Variant B Variant C...

Page 3: ...at least concrete feet have been prepared in advance or a flat surface is available to which the pergola is to be installed The recommended minimum foot dimensions are 300 300 mm frostproof depth A 1...

Page 4: ...pole A1 and pole C1 so that the pre installed 6HR screws fit in the grooves Tighten the pre installed 6HR screws on both sides of the perimeter section A1C1 A 10 Insert two cup head bolts M10 20 to ea...

Page 5: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 5 GROUND MOUNTING variant A FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES...

Page 6: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 6...

Page 7: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 7...

Page 8: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 8...

Page 9: ...tallation of the pole A3 and pole C3 Then proceed in accordance with items A 1 through A 4 above B 3 Insert the perimeter section A1A3 to the pre installed pole A3 and press it against the wall mounti...

Page 10: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 10 Wall Mounting Variant B figures to illustrate the above activities B5 B6...

Page 11: ...n both sides of the pergola and the flatness of the perimeter section C 2 Remove the eaves gutter from the perimeter section A1A3 the gutter is not treated with sealing compound at the lower side C 3...

Page 12: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 12 WALL MOUNTING VARIANT C FIGURES TO ILLUSTRATE THE ABOVE ACTIVITIES C3...

Page 13: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 13 C6...

Page 14: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 14 STRUCTURAL PARTS TO BE TREATED WITH SEALING COMPOUND Silicone gutter corner...

Page 15: ...al junction box is located in the section A1 A3 or C1 C3 together with the motors and ensures 220 V power supply for the motors and LED lighting unit The junction box can be removed if necessary to pa...

Page 16: ...DIFFER ACCORDING TO THE METHOD OF CONTROL NUMBER OF MOTORS AND INSTALLED TYPE OF LIGHTING Multi motor Pergolas Controls are carried out by Situo 5 Variation io controller or other types of controller...

Page 17: ...nstalling screen roller blinds If a larger box is used and the roller blinds are attached to the pergola corner joints the rear sides of the boxes will collide and in such a case neither roller blind...

Page 18: ...la is delivered with an IO controller the individual motors are paired with the controller and the extreme positions of the motors are set start and end position of the slats If the IO remote control...

Page 19: ...a year in spring and before winter treat the rubber seal with a product designed for this purpose silicone spray etc Continuously remove coarse dirt such as twigs and branches from the slats of the pe...

Page 20: ...NT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 20 Pergola Anchoring Template The through hole is always oriented to the exterior side of the pergola View of the foot from the inner side of th...

Page 21: ...MEASUREMENT AND ASSEMBLY MANUAL Validity of the manual 21 3 2022 21 Construction readiness...

Reviews:

Related manuals for ARTOSI