background image

S

tylos 2 

All Weather

  

INSTALLATION GUIDE (UK)

WARNINGS

Read this manual prior to use the device in order to ensure a safe and proper use.

Preserve this manual as future reference.

The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

The instructions should be carefully followed during installation. These instructions and any maintenance 
instructions should be passed on by the installer to the user.

No modifications of any kind are permitted, except for those described in these instructions.

The product must be destined only for the use for which it is expressly designed and therefore as a 
credential reader for civil and industrial locations. Any other use is considered improper and dangerous.

The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.

In the event of a failure and/or poor operation, remove the power supply using the main switch and do not

tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.

Before performing any cleaning operation on the product, uncouple the appliance from the electrical power

supply network, by opening the system switch.

1. VERSIONS AND DIMENSIONS

4.1 

READER/VALIDATOR

 ELECTRICAL CONNECTIONS

This guide includes instruction to configure the Stylos as 

Stand-Alone gate

 or as 

Reader/Validator

, connected to Atlas. Refer to the proper section.

ELECTRONIC SUPPORT SERVICE
iseozero1

.com

®

i s e o

. c o m

Iseo Serrature s.p.a 
Via San Girolamo 13 
25055 Pisogne (BS) 
ITALY
Tel. +39 0364 8821 
[email protected]

Non contractual document. Subject to change. Cod. 60000STY2CV01.5 - 08/05/2018

Stylos 2 Credential Reader All Weather Inst. guide (GB) - © 2017  Iseo Serrature S.p.a. - www.iseo.com

A = 47,5mm
B = 17,5mm
C = 130mm

A = 45mm
B = 19,3mm
C = 113mm

A = 40mm
B = 10mm
C = 125mm

C

A

B

Credential reader

(outdoor module)

Control unit 

(indoor module)

Spacer for wall

installation

2

1

PUSH

PUSH

PULL UP

PULL UP

Side view

Back view

2. DISASSEMBLING INDOOR MODULE

3. 

STAND-ALONE GATE 

SETTING

Only to set the Stylos 2 All Weather to be used as 

Stand-Alone gate

, you have to close, by a wire, 

holes 2 and 3 of the green connector shown in the 
picture.

Fit the wire when the
Stylos is OFF.

ADDRESS  5 =

ADDRESS  6 =

ADDRESS  7 =

ADDRESS  8 =

ADDRESS  1 =

ADDRESS  2 =

ADDRESS  3 =

ADDRESS  4 =

BUS
ADDRESS

JP 1

Power supply: 8÷30 VDC 0,5A 

MAX

Minimum/maximum cross-section of the 
cables is: 0,20÷1,5 mm (24÷15 AWG).
Do not extend the cable supplied with the 
external device (5 mt.).
Install the internal device only in a protected 
area.

(Communication Channel)

NEGATIVE (-) GND

POSITIVE (+) Power Supply

LOCKBUS

}

ADDRESS

BUS

J2.

1

J2.

2

J2.

3

J2.

4

JP

6

JPS

S1

JP

4

JP

2

JP

0

JP

6

JP

4

JP

2

JP

0

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

GREEN + GREY + SHIELD (or black)
RED
WHITE
BROWN
YELLOW
PINK
BLUE

Control Unit
Circuit View

JP

6

JP

4

JP

2

JP

0

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

1
2
3
4
5

Stylos as 

Stand-Alone gate

 = Address 0 (Master)

Control Unit
Circuit View

3.1 

STAND-ALONE GATE

 ELECTRICAL CONNECTIONS

LEGEND:

S1 = Programming button
JP 0/2/4/6 = Bus Address Jumpers

ADDRESS  0 =

ADDRESS  2 =

ADDRESS  4 =

ADDRESS  6 =

BUS
ADDRESS

(Master)

(slave)

(slave)

(slave)

FUNCTION

JP

4

JP

2

JP

0

JP

6

    Do not extend the cable supplied
    with the external device (5 mt).
    Install the internal module only in 
    a protected area.

mm²

0.20÷1.5 

Minimum/maximum cross-section
of the cables is:

(24÷15AWG).

    Power supply: 8÷30 VDC 0.5A 

MAX

(Communication Channel)

NEGATIVE (-) GND

POSITIVE (+) Power Supply

LOCKBUS

}

ADDRESS

BUS

J2.

1

J2.

2

J2.

3

J2.

4

JP

6

JPS

S1

JP

4

JP

2

JP

0

JP

6

JP

4

JP

2

JP

0

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

Control Unit
Circuit View

GREEN + GREY + SHIELD (or black)
RED
WHITE
BROWN
YELLOW
PINK
BLUE

1
2
3
4
5

4. 

READER/VALIDATOR 

SETTING

JP

6

JP

4

JP

2

JP

0

J2.

1

J2.

2

J2.

3

J2.

4

JPS

S1

Stylos as 

Reader/Validator

 = Address 1

For more information about Stylos and Atlas, refer to 
the 

Atlas Installation Manual 

available at:

http://gamma.iseozero1.com/en/controllo-accessi/

1
2
3
4
5

Control Unit
Circuit View

Reviews: