GTX12V315A-E2107-CS200RV INSTALLATION KIT

LITHIONICS BATTERY, CLEARWATER, FL 33765 USA | PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.com

Revision 03

VICTRON 2000 WATT

 Installer's Guide

Summary of Contents for VICTRON 2000

Page 1: ...GTX12V315A E2107 CS200RV INSTALLATION KIT LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Revision 03 VICTRON 2000 WATT Installer s Guide ...

Page 2: ... INVERTER DIAGRAM STERLING DIAGRAM SOLAR DIAGRAM BATTERY IONGAGE DIAGRAM PARTS LIST BATTERY INSTALLATION EQUIPMENT MANUALS Table of Contents LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 2 4 7 10 12 14 16 17 20 ...

Page 3: ...rn OFF equipment connected to the battery and the Power switch on the battery This will isolate the battery from other electrical circuits This must occur before performing any repairs or maintenance on the system Proper wire size is essential when connecting the inverters chargers and other equipment in the system Crimped connections are required when connecting to the battery terminals Read and ...

Page 4: ...2000 watt inverter The kit is limited to 300Amps DC If a larger inverter or battery bank is anticipated in a future expansion then one of our larger kits with higher capacity components is recommended 2 LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Introduction ...

Page 5: ...ain Diagram Inverter Diagram Sterling Diagram Solar Diagram Battery IonGage Diagram Wiring Diagrams LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 3 ...

Page 6: ... to isolate the inverter in the case of a malfunction as well as disabling the inverter if work is required on the AC system If the inverter is installed more than five feet from the fuse block the wire size should be increased to 4 0 to compensate for voltage drop The chassis DC grounding conductor green should be sized not less than one size smaller than the DC positive conductor and have a capa...

Page 7: ...arger is connected to the MRBF fuse block via a 40A fuse and an isolation switch The PV solar array is connected to the MPPT charger via a circuit breaker The specified circuit breaker is only rated at 48VDC if your PV solar array has an open circuit voltage that is higher then another circuit breaker with a higher voltage rating must be substituted The fuse and wire sizes are based on the Victron...

Page 8: ...MAIN DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 6 ...

Page 9: ...ker rated at 50A or less and the cable cross section must be sized accordingly Make all connections using proper crimp on connectors do not use twist on connectors The inverter has a Power Assist feature and when enabled can add up to 2kVA 2000 120 17A to the output during periods of peak power requirement With a maximum input current of 50A the inverter can supply up to 67A 50 17 Inverter Diagram...

Page 10: ...installation the inverter chassis must be connected to the vehicle chassis ground via the negative distribution buss The chassis grounding conductor must be not less than one size smaller than the DC positive conductor and have a capacity such that the DC positive fuse has an amperage rating not greater than 135 of the current rating of this grounding wire When using an inverter sub panel the inve...

Page 11: ...INVERTER DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 9 ...

Page 12: ...the Sterling BB1230 charger Mercedes recommendation or the BB1260 charger depending on the size of the alternator The charger should be programmed to charge the battery using a Lithium battery profile The charger can also be configured to work with vehicles using regenerative braking Sterling Power Battery to Battery Charger 12V input to 12V output 30amps Sterling Power Battery to Battery Charger ...

Page 13: ...STERLING DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 11 ...

Page 14: ...an open circuit voltage that is higher then another circuit breaker with a higher voltage rating must be substituted The charger is connected to the MRBF fuse block via a switch and a 40A fuse The fuse and wire sizes are based on the Victron MPPT 100 30 charge controller If a larger controller is used then the fuse and wire sizes should be increased as required Remotely control and monitor the Vic...

Page 15: ...SOLAR DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 13 ...

Page 16: ...ata will only be correct if the configuration parameters are set correctly which are pre set initially by Lithionics Battery but are user adjustable with supporting hardware The SOC Gauge will also track and display live amperage A live wattage W battery voltage V temperature F C amp hours Ah watt hours Wh time remaining d h etc The meter will be most accurate if the battery is fully charged on a ...

Page 17: ...BATTERY IONGAGE DIAGRAM LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 15 ...

Page 18: ...QTY PART NUMBER DESCRIPTION COMMENTS Parts List LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com 16 ...

Page 19: ...into the Power button to make sure it is completely off If the LED is on or blinking press and hold the Power button for 3 seconds until LED turns off Lithium batteries do not release gas during normal use There are no specific ventilation requirements for battery installation although enough airflow should be provided to prevent excessive heat build up The battery should be stored and installed i...

Page 20: ...gh resistance path and cause excessive heating of the connection which could then lead to permanent battery damage or fire If you must attach more than one lug to each terminal make sure at least 1 4 or 6mm of thread is available to secure the connection Additionally the ring terminal lugs need to be clocked in such a way that they do not interfere with their flat conducting surfaces Acquire and u...

Page 21: ...d load and not to exceed the battery specifications After installation is complete turn on the battery power by a short press of the Power button The LED indicator should come on to confirm the battery s state Battery Installation LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com DO NOT connect multiple batteries in series to get higher voltage a...

Page 22: ...or the manufacturer equipment manuals LITHIONICS BATTERY CLEARWATER FL 33765 USA PH 727 726 4204 FAX 727 797 8046 WEB LITHIONICSBATTERY com Equipment Manuals Victron Inverter Victron MPPT Solar Charger Sterling Charger Lithionics Battery ...