background image

MEASURE OF SUCCESS

USER INSTRUCTIONS

www.inor.com, www.inor.se

The manual must be read prior to adjustment

and/or installation. All information subject to

change without notice.

86BIQ00006 2003-5

SWEDEN

GERMANY

USA

ADDRESS

1860 Renaissance Blvd.
Sturtevant, WI 53177, USA

PHONE

+1-262-884-4535

FAX

+1-262-884-4537

E - M A I L

[email protected]

ADDRESS

PO Box 9125
S-200 39 MALMÖ, Sweden

PHONE

+46-40-31 25 60

FAX

+46-40-31 25 70

E-MAIL

[email protected]

ADDRESS

Rodenbacher Chaussee 6
D-63457 Hanau-Wolfgang; Germany

PHONE

+49-6181-582940

FAX

+49-6181-582944

E-MAIL

[email protected]

FINLAND

ADDRESS

Unikkotie13
01300 VANTAA, Finland

PHONE

+358- 9-83850210

FAX

+358-9-83850219

E-MAIL

[email protected]

The transmitter is configured from a standard IBM compatible PC by

using the IPRO software version 3.07 or later. The latest version of

IPRO can be downloaded from http://www.inor.com. When the

transmitter is set from a PC no calibration is needed.

     When calibrate/configure ”online” with the input

connected to hazardous area the ATEX certified version of

IPRO-X cable must be used.

The transmitter is polarity protected and will not be damaged by

connecting the power supply with the wrong polarity, but the out-

put will be 0 mA.
The maximum load in the output loop depends on the supply

voltage,see ”DATA shortform”

”Isolation input/output/PC” mentioned in the data sheet,

indicates signal isolation only. It shall not be interpreted as

an IS galvanic isolation like an isolating barrier. Therefore

ordinary care in selecting barrier and grounding should be

considered for the IPAQ-LX.

Sensor wire check: the transmitter uses a pulsating technique to

monitor sensor break or sensor shortened to avoid measuring errors.

This pulsating signal may interfere with some electronic calibrators.

By selecting ”Sensor Break = None” in the IPRO software and

download the configuration into the transmitter the pulsating signal

is turned off.

GENERAL INFORMATION

INTRODUCTION

IPAQ-L is a universal and intelligent 2-wire rail-mounted transmitter

for temperature and other measurement applications.

IPAQ-LX is the Intrinsic Safe version for use in Ex-applications.

DIMENSIONS

Intelligent 2-wire

DIN Rail Temperature

Transmitter

CONFIGURATION

The IPAQ-L/LX transmitter must be powered, when you configure

the transmitter, (see ”Connections” fig.1). If IPRO (the IPAQ  software)

isn’t installed in your PC, install the software.

For keeping the safety of the internal circuits in the

IPAQ-LX, always use Ex-power supply or a zener barrier with

limitations according to Ex-data and IPRO-X configuration

cable when making a configuration.

When choosing differential temperature measuments with Pt100 be

sure to select ”sensor break” = none.

Configuration from PC is ”on-line”, that is, the transmitter can be

configured while in operation if the area is known to be non-hazardous.

The output is frozen while transmission from PC to IPAQ take place.

When transfer is done the transmitter uses the new parameters.