background image

All-Purpose Temperature Controller 

 

ITC-1000F 

User Manual 

Version 1.0s 

 

 

 

 
 

 

 

Inkbird Tech. Co., Ltd. 

 
 
 
 
 
Copyright 

Copyright

©

  2016  Inkbird  Tech.  Co.,  Ltd.  All  rights  reserved.  No  part  of  this  document  may be  reproduced 

without prior written permission. 
 

Disclaimer 

Inkbird  has  made  every  effort  to  ensure  that  the  information  contained  in  this  document  is  accurate  and 
complete;  however,  the  contents  of  this  document  are  subject  to  revision  without  notice.    Please  contact 
Inkbird to ensure you have the latest version of this document. 

Summary of Contents for ITC-1000F

Page 1: ... No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject to revision without notice Please contact Inkbird to ensure you have the latest version of this document ...

Page 2: ...00F 12V 5 4 Keys Instruction 6 5 Key Operation Instruction 6 5 1 Check Parameter 6 5 2 Parameter Setting 6 5 3 Operating instruction 7 6 Menu Instruction 8 6 1 When the set temperature is degrees Celsius FC C 8 6 2 When the set temperature is degrees Fahrenheit FC F 8 7 Error Description 9 Sensor Error Alarm 9 Over temperature Alarm 9 8 Technical Assistance and Warranty 10 8 1 Technical Assistance...

Page 3: ...tric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur Never disassemble modify or repair the product or touch any of the internal parts Electric Shock fire or malfunction may occasionally occur If the output relays are used past their life expectancy contact fusing or burning may occasionally occur A...

Page 4: ...xceeds the Limit or When Sensor Error Mounting dimension Front Panel Size 75 L 34 5 W mm Mounting Size 71 L 29 W mm Product Size 75 L 34 5 W 85 D mm Sensor Length 2m include the probe Temperature Measuring Range 50 210 o F 50 o C 99 o C Resolution 0 1 o F 0 1 o C Measuring Accuracy 1 o F 50 o F 160 o F 1 o C 50 o C 70 o C Power Supply 110Vac 220Vac 50Hz 60Hz 12Vdc Power Consumption 3W Sensor NTC S...

Page 5: ...er wire should be kept a proper distance 3 2 ITC 1000F 220V Note Strictly distinguish interface of relay sensor and power Strictly distinguish connection of sensor and power Sensor down lead and power wire should be kept a proper distance 3 3 ITC 1000F 12V Note Strictly distinguish interface of relay sensor and power Strictly distinguish connection of sensor and power Sensor down lead and power wi...

Page 6: ...mode set indicator lamp is on screen displays the first menu code TS Press key or key to move up or down the menu item and display the menu code Press key to enter the parameter setting of current menu the parameter value starts to flash Press key or key to adjust the parameter value of current menu After the set press key to exit the parameter setting of current menu the parameter value stops to ...

Page 7: ...ling automatically If the measuring temperature temperature set value difference set value the controller starts refrigerating the cool indicator lamp lights on and the refrigerating relay is connected When cool indicator lamp flashes indicating that the refrigerating device is under compressor delay protecting status If the measuring temperature temperature set value the cool indicator lamp turns...

Page 8: ...utes 3munites CA Temperature Calibration Value 15 o C 15 o C 0 o C CF Fahrenheit or Celsius Setting C 6 2 When the set temperature is degrees Fahrenheit FC F Code Function Set range Default Note TS Temperature Set Value 50 210 o F 50 o F Min Unit 1 o F DS Difference Set Value 1 30 o F 3 o F PT Compressor Delay 0 10 minutes 3 minutes CA Temperature Calibration Value 15 15 o F 0 o F CF Fahrenheit or...

Page 9: ...ays ER Press any keys can cancel buzzer alarm the system returns to the normal working status after error is cleared Over temperature Alarm When the measuring temperature exceeds the temperature measuring range the controller starts over temperature error alarm mode and closes all running status the buzzer alarm sounds screen displays HL Press any keys can cancel buzzer alarm the system returns to...

Page 10: ...condition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the thermostat The original receipt is required for warranty purposes INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising...

Reviews: