background image

Quick

 

Start

Guida Rapida

A New Interactive Experience

Summary of Contents for ipdoor Flush

Page 1: ...Quick Start Guida Rapida A New Interactive Experience ...

Page 2: ... OXVK 7RXFK 130mm 95mm 20mm 2mm 25mm 42mm 262mm 311mm ...

Page 3: ... the top of the screen access the network settings select your network from those available and enter the access data RQƪJXUD LRQH RQƪJXUDWLRQ 90 90 0 180 45 315 270 90 225 135 Vista dall alto Top View Area a bassa copertura Low coverage area Area ad alta copertura High coverage area Vista Frontale Front View 20m 10m 15m 10m Per ottenere prestazioni migliori posizionare la targa nell area ad alta ...

Page 4: ...aggiungere un pulsante apriporta esterno collegare il pulsante WUD L PRUVHWWL 1 R 1 H 0 HG DVVRFLDUH OoLQJUHVVR VFHOWR DOOoD LRQH uscita OUTPUT nelle impostazioni della targa The inputs IN1 and IN2 must refer to ground M To add an external door opener button connect the button between termi nals IN1 or IN2 and M and associate the chosen input with the OUTPUT output action in the door station setti...

Page 5: ...45 EIA TIA 568B CAT5 6 Presa di rete Network Socket Scheda rete Network Card 10 100Mbps PoE IEEE 802 3af A 51mm Made in italy A Porta Ethernet Ethernet port B Morsetto estraibile a 10 poli Removable 10 pole terminal C Ripristino impostazioni di fabbrica Premere per 10 secondi al riavvio Factory reset Hold for 10 seconds on reboot 51mm ...

Page 6: ...ositivo 9 H QHJDWLYR PDVVD FRQ XQ FDYR HOHWWULFR GL OXQJKH D PDVVL PD PHWUL e VH LRQH PLQLPD PP The door station has a 12V 1A powered output for the drive of an electric lock without the aid of an additional power supply The locks must be connected following the manufacturer s scheme to the terminals LOCK and LOCK respectively positive 12V and negative earth with an electric cable with a maximum l...

Page 7: ... negativo all ingresso M sui morsetti della targa Use a 24V 0 5A stabilized power supply like ICA0001 Referring to the 24V output of the power supply connect the positive to the 24V 0 5A input and the negative to the M input on the door station clamps ROOHJDPHQWR OLPHQWDWRUH VWHUQR External Power Supply Connection 85 264 V 24V 24V 0 5A M INPUT OUTPUT L N L v v N L ...

Page 8: ...m suppor ted load of 1A 24V or 1A 24V ROOHJDPHQWR 8VFLWD 5HOÃ Relay Output Connection Alimentatore Power Supply L AUX1 220V AUX1 AUX1 AUX1 Max 24V 1A Max 24V 1A o Alimentatore Power Supply Schema di collegamento diretto Direct connection diagram 6FKHPD GL FROOHJDPHQWR WUDPLWH UHOÃ GL SRWHQ D Connection diagram via power relay Max 24V 1A Max 24V 1A o ...

Page 9: ...ation is made connecting WKH LQWHJUDWHG K L ƪ FDUG to a wireless access point or router This type of connection requires the use of an external 24V power supply like ICA0001 to be connected directly to the door station Schema con collegamento di rete wireless ed alimentatore esterno Diagram with wireless network connection and external power supply QVWDOOD LRQH WI FI Installation CAT 5 6 368 9 Doo...

Page 10: ... a CAT5 6 network cable between the network card located on the back of the door station and the router or switch This type of connection requires the use of an external 24V power supply like ICA0001 to be connected directly to the door station Schema di collegamento con cavo di rete CAT5 6 ed alimentatore esterno Connection diagram with CAT5 6 network cable and external power supply QVWDOOD LRQH ...

Page 11: ...d on the back of the door station and an injector like the ICA0002 or an IEEE802 3af PoE switch In this case the power is supplied directly through the network cable therefore it is not necessary to use an external power supply Schema di collegamento con cavo di rete CAT5 6 ad un dispositivo PoE IEEE802 3af senza alimentatore esterno Connection diagram with CAT5 6 network cable to a PoE IEEE802 3a...

Page 12: ...WH D GL FLUFD FP GDO pavimento To install the TOUCH IP120D door station it is necessary to vertically wall a model 503 wall box or a 60mm diameter round wall recessed box at a KHLJKW RI DERXW FP IURP WKH ƬRRU VWUX LRQL SHU OoLQVWDOOD LRQH GHOOD WDUJD 7RXFK Instructions for installing the Touch door station 7RXFK Da Terra Floor 150 160cm Foro a parete Hole on wall ...

Page 13: ...tte della scatola 503 Disegnare sulla parete le posizioni dei quattro fori evidenziati dalle IUHFFH LQ ƪJXUD Place the supplied hooking plate on the wall r OLJQ WKH WZR VORWV KLJKOLJKWHG E WKH EOXH FLUFOHV LQ WKH ƪJXUH ZLWK WKH turrets of the 503 box Draw on the wall the positions of the four holes highlighted by the arrows LQ WKH ƪJXUH ...

Page 14: ...ando una punta da 4mm Inserire i tasselli in dotazione assicurandosi che siano perfettamente allineati con la parete Drill the wall at the points previously drawn using a 4mm bit Insert the supplied plugs making sure they are perfectly aligned with the wall Da Terra Floor 150 160cm ...

Page 15: ...nstalled Fissare la piastra di aggancio avvitando le quattro viti fornite a corre GR FRPH LQGLFDWR LQ ƪJXUD Bloccare con una quinta vite la piastra di aggancio alla scatola da muro YLWH FHQWUDOH Fasten the coupling plate by tightening the four screws supplied as shown LQ WKH ƪJXUH r DVWHQ WKH DWWDFKPHQW SODWH WR WKH ZDOO ER ZLWK D ƪIWK VFUHZ FHQWUDO screw ...

Page 16: ...a parete e piastra d aggancio disegnando una U rovesciata nella zona evidenziata QHOOD ƪJXUD Check that the plate is perfectly adherent to the wall If the surface of the wall is uneven and the alignment of the plate is inaccu rate it will be necessary to apply silicone between the wall and the hooking SODWH E GUDZLQJ DQ LQYHUWHG 8 LQ WKH DUHD KLJKOLJKWHG LQ WKH ƪJXUH Silicone Silicone Retro Back ...

Page 17: ...LUH OD WDUJD SDUDOOHODPHQWH ULVSHWWR DOOD SDUHWH ƪQR D VHQWLUH LO FRQWDWWR WUD OH GXH ODPHOOH HYLGHQ LDWH LQ ƪJXUD Complete the device wiring before proceeding to the next step Insert the door station parallel to the wall until you feel the contact EHWZHHQ WKH WZR VODWV KLJKOLJKWHG LQ WKH ƪJXUH ...

Page 18: ...e 1 Slightly tilt the door station and press in the area highlighted in the ƪJXUH FRPSUHVVLQJ WKH JDVNHW XQWLO RX KHDU WKH FRXSOLQJ EHWZHHQ WKH WZR blades 2 Slide the door station slightly downwards 3 Rotate the lower part until it aligns with the wall 4 Screw in the locking screw to complete the installation Area di pressione Pushing area Non premere sullo schermo Do not press on the screen 1 3 1...

Page 19: ...GL EORFFDJJLR WLUDUH YHUVR OoHVWHUQR OD SDUWH inferiore e sollevare il dispositivo in modo da sganciarlo dalla piastra To release the door station Unscrew the locking screw all the way pull the bottom part outwards and lift the device to release it from the plate ...

Page 20: ...l interno della scatola sporgano di circa 1mm To install the FLUSH IP220D door station it is necessary to wall the built in box model ICA0010 vertically at a height of about 155 165 cm from the ƬRRU making sure that it is perfectly aligned with the wall and that the two hooks present inside the box they protrude about 1mm OXVK VWUX LRQL SHU OoLQVWDOOD LRQH GHOOD WDUJD OXVK Instructions for install...

Page 21: ... una chiave D EXVVROD GD PP H VSRVWDUH LO JDQFLR ƪQR DG RWWHQHUH OD SRVL LRQH desiderata Richiudere con forza prima di innestare la targa If the box is not perfectly aligned with the wall you can adjust the position of the two hooks so that they are perpendicular to the wall and protruding by about 1mm To adjust loosen the two nuts on each hook with a 5 5mm socket wrench and move the hook to obtai...

Page 22: ...OH GXH molle Non premere mai direttamente sullo schermo touch Assicurarsi FKH OD WDUJD VLD VDOGDPHQWH ƪVVDWD DOOD EDVH Complete the device wiring before proceeding to the next step Keep the door station parallel to the wall and insert it in box compartment until you hear the coupling with the two springs Never press directly on the touch screen 0DNH VXUH WKDW WKH GRRU VWDWLRQ LV ƪUPO ƪ HG WR WKH E...

Page 23: ...DYH GL VEORFFR Ã QHFHVVDULR ULSRVL LRQDUH OD JXDU nizione di gomma all interno della feritoia To extract the door station from its housing insert the release key in the appropriate slot until you hear the release of the spring that unlocks the door station Remove the door station by pulling it outwards After using the release key it is necessary to replace the rubber gasket inside the slot OXVK 2X...

Page 24: ...e received including interference that may cause undesired operation FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment We are exempt from RF Exposure evaluation because the physical structure of the object always guarantees the distance of 40mm between the radiating element and the user s fin...

Page 25: ...VXOWDUH OD GRFXPHQWD zione completa accedi alla FRQVROH GL DPPLQLVWUD LRQH 7R FRQƪJXUH WKH GHYLFH DQG FRnsult the complete documen tation access the administration console https console ipdoor com ZZZ LSGRRU FRP IT EN 6FDULFDELOH VX Available on ...

Reviews: