XTM Series

TM-102

Technical Description

TM-102 DC, 19"/ETSI/23" (TM102-DC)
TM-102 passive,19"/ETSI/23" 1xL+1xS (TM102-PAS-L-S)
TM-102 passive,19"/ETSI/23" 3xS (TM102-PAS-3S)

TD-TM102

Rev R

|

2018-06-25

Summary of Contents for XTM Series

Page 1: ...XTM Series TM 102 Technical Description TM 102 DC 19 ETSI 23 TM102 DC TM 102 passive 19 ETSI 23 1xL 1xS TM102 PAS L S TM 102 passive 19 ETSI 23 3xS TM102 PAS 3S TD TM102 Rev R 2018 06 25...

Page 2: ...the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Modifyi...

Page 3: ...ort policies and procedures to download software updates and product documentation to view training course information or to create update incident reports and RMA requests Documentation Feedback Infi...

Page 4: ...ck Mount Options 3 2 2 1 19 ETSI or 23 3 2 2 2 300mm or 300mm rack mount 4 3 Active TM 102 5 3 1 Primary Power Alternatives 5 3 2 Slot Numbering 6 3 3 Management Access 6 4 Passive TM 102 7 5 Running...

Page 5: ...ug in unit compatibility matrix F 2014 05 15 R23 updates Updated plug in unit compatibility matrix G 2014 09 15 R23 1 updates Updated plug in unit compatibility matrix H 2014 12 20 R24 0 updates Updat...

Page 6: ...ive boards need to electrical power to function they have an onboard EEPROM circuit to enable extraction of inventory data In the active TM102 DC chassis this inventory information can be extracted an...

Page 7: ...gh One active slot and one passive slot Dual DC power External AC DC converters Fixed fan units 2 2 Rack Mount Options At delivery the TM 102 chassis is equipped with 19 mounting brackets For details...

Page 8: ...are for 19 and for mounting depths 300mm An additional pair of mounting brackets is provided that enables the TM 102 chassis to be mounted in 300mm racks both for ETSI as well as 19 mounts The front o...

Page 9: ...ing on selected country code and with an appliance connector of type C13 IEC 60320 1 The AC appliance connector type of the PSU is C14 IEC 60320 1 Fig 4 External AC DC converter Table 3 AC DC converte...

Page 10: ...en on the front under the card slots 3 3 Management Access Ethernet based access is done via the RJ 45 connector located on the front side DCN 1 The electrical Ethernet interfaces can be connected to...

Page 11: ...4 Passive TM 102 There are two passive versions of the TM 102 TM102 PAS L S 1 full sized and 1 half sized Any passive full or half height can be mounted in the passive TM 102 chassis TM102 PAS 3S 3 h...

Page 12: ...e slot Line protection of client protection that is configured within the same board is however fully feasible As an example a TPQMR has four Transponder functions on the same board and client protect...

Page 13: ...n Units An active unit e g Transponder must fulfill two requirements to be mounted in a TM 102 chassis Support CU less configuration i e can run without a Control Unit Does not consume more electrical...

Page 14: ...ess EOA E means End Of Availability Effective The board is no longer orderable The 40G and 100G units are not part of the table since they require two or three slots Table 4 Plug in units TM 102 compa...

Page 15: ...TM 64 Muxponder 4x2G5 MXP10G A FH 1 2 NA NA EOA E 100G line rate Flexponder 400G OTN FXP400GOTN A FH 1 NA NA NA Layer 2 10xGbE 10GbE Ethernet Mux ponder II GBE10 EMXP10 II A FH 1 2 NA NA 22xGbE 10GbE...

Page 16: ...Add Drop AD1 2F xxxxx P HH 1 3 3 2 4 4ch 2 fiber DWDM Add Drop AD4 2F xxxxx P HH 1 3 3 2 4 2ch DWDM OADM xxx yyy OADM2CH xxx P HH 1 3 3 2 4 4ch DWDM Add Drop Even 50GHz AD4 50G E xxx P HH 1 3 3 2 4 4c...

Page 17: ...9185 9255 P FH 1 NA 2 NA MDU E 8ch Odd 50GHz DWDM MDU8EO9265 9335 P FH 1 NA 2 NA MDU E 8ch Odd 50GHz DWDM MDU8EO9345 9415 P FH 1 NA 2 NA MDU E 8ch Odd 50GHz DWDM MDU8EO9425 9495 P FH 1 NA 2 NA MDU E 8...

Page 18: ...A FH 1 2 NA NA Opt Flat Gain Amp C Band 10 dBm OA10C FG A FH 1 2 NA NA Variable Gain Ampl 20dBm C band II OA20C VG II A FH 1 2 NA NA Dual Var Gain Ampl 20dBm C band II OA2 20C VG II A FH 1 2 NA NA RA...

Page 19: ...102 TM 102 PAS L S TM 102 PAS 3S EOA status 8ch CWDM Mux fiber pair 8ch CWDM De Mux fiber pair MU 2F 1470 DU 2F 1470 P HH 1 3 3 2 4 4ch CWDM MDU fiber pair Extendable MDU4 E 2F P HH 1 3 3 2 4 4ch CWDM...

Page 20: ...on the left front side Fig 7 Labels The Product label contains Fig 8 Product Label 1 Infinera logotype 2 Product number 3 Product revision 4 Barcode 128 containing product number space revision 5 Prod...

Page 21: ...nventory function in the management system Inven tory data on CU s and Traffic Units are available via the inventory functionality The System Label contains Fig 9 System Label 1 Infinera logotype 2 Sy...

Page 22: ...00 019 1 3 class T3 1 9 1 Environmental conditions Configurations with the TM 102 chassis supports ETSI EN 300 019 1 3 T3 1 5 to 40 C 41 to 104 F and ETSI EN 300 019 1 3 T3 1E 5 to 45 C 23 to 113 F Se...

Page 23: ...rack depth 2 per chassis Mounting brackets 19 for 300mm rack depth 2 per chassis Mounting brackets ETSI for 300mm rack depth 2 per chassis Extension brackets 19 to ETSI and 23 2 per chassis Table 8 AC...

Page 24: ...Proprietary and Confidential Table 9 Spare parts Item name Item code Comment Dummy panel 6HE inkl ovl o EMC list M3 DU 6HE Full height slot cover panel Dummy panel 3HE inkl ovl o EMC list M3 DU 3HE Ha...