manualshive.com logo in svg
background image

 
 

 
 
                                       
                                             
                           
 
 

                             

 

 

 

 

 

 

 

 

 

 

                                 

 

 

 

                 

 

 

 

 

                   

VERSION:V 2.0

 

 

   

       

 

       

   

 

 

This manual contains important laser system safety and operation 

information. Read and understand all instructions prior to powering on 

laser unit the first time, to avoid laser eye injury and to avoid breaking 

the law. Keep this manual in a safe place for future reference.

 

Содержание LSX-142SRGY StageLine

Страница 1: ...ant laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this manual in a safe place for future reference ...

Страница 2: ...laser incident or damage Prevent damage or injury from incorrect operation Laser safety warming labels To protect the environment recycle packing material wherever possible The projector is for indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects Don t thr...

Страница 3: ...le parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure NON INTERLOCKED HOUSING WARNING This unit contains high power laser devices inter...

Страница 4: ...products split the laser into hundreds of beams or laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliwatts of laser power Class 4 levels internally Many of the individual beams are potentially hazardous to the eyes It is also incorrect to assume that because the laser light is moving it is safe This is not true Nor...

Страница 5: ... or open or if optics appear damaged in any way Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury Never leave this device running unattended The operation of a Class 4 laser show laser is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in...

Страница 6: ... beam output aperture LASER EMISSION DATA As measured under IEC measurement conditions for classification Laser Classification Class 3B Green Laser Medium DPSS Nd YVO4 532nm Red Laser Medium LD GaAIAs 650nm typical Beam Diameter 5mm at aperture Divergence each beam 12 mrad Divergence total light 90 degrees Laser power R 100mW G 40mW Transverse Beam Mode TEM00 Cooling TEC Fan Cooling Scanning ILDA ...

Страница 7: ...er will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the devise are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure ...

Страница 8: ...operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The minimum distance between the fixture and surrounding walls must be more than 50cm Always fix the fixture with an appropriate safety rope Fix the safety rope at the saf...

Страница 9: ... packing What is included The carton or flight case contain following items Power Supply To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture of refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit a...

Страница 10: ... in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection Caution At the laser fixture the DMX cable has to terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug and plug it in the DMX output...

Страница 11: ...plug it in the DMX output of the last fixture Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DXM output a...

Страница 12: ...ser light and audience or other public spaces Rigging the Fixture The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of...

Страница 13: ...ear The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated PRODUCT OVERVIEW This device has left out premise in absolutely perfect condition In order to maintain this condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not a...

Страница 14: ...cated LED Red is ON 3 MUSIC IR Synchronize to detected music signal IR indicator flashing for each signal received 4 IR Infrared Remote Receiver 5 Cooling fan Cooling and never cover this fan outlet 6 HANGING BRACKET with 2 knobs on both sides to fasten the unit and a mounting hole to fix a mounting hook ...

Страница 15: ...or start servicing In the event of serious operation problems stop using the fixture and contact your dealer immediately NO NAME FUNCTION 7 Switch Switch on and off the power 8 Mains input With socket and integrated fuse holder 9 Key switch Make sure the professional person use 10 Interlock For emergency laser stop 11 LED control Panel Intelligent LED control panel of the system 12 Safety eye Atta...

Страница 16: ...ser is powered on LCD monitor on rear panel shows the current operating standalone mode or DMX address of DMX mode With help of LCD control panel is very easy to set and change the operating mode of laser After every resetting and saved the new mode information will be shown on LCD monitor at next power on Mode Option to choose the operating mode of laser Confirmation to confirm the laser to show ...

Страница 17: ...TIVATED SHOW with single YELLOW AUP Auto running pattern effect show SOP Sound activated pattern effect show Attention In preprogrammed standalone MUSIC SHOW mode the laser beam will be blank out in 3 seconds without AUDIO MIC activated signal DMX MODE Press FUNC to enter MODE selection Till to LED panel shows 001 Press ENTER to confirm setting The laser is working in DMX MODE With help of UP and ...

Страница 18: ...ional Press FUNC to enter MODE selection Till to LED panel shows REM Press ENTER to confirm setting Please check Remote Instruction for remote control details Attention In any standalone mode excepted REM and SLA press ON OFF for 2 second to activate remote function PATTERN MIRROR REVERSE SETTING Press FUNC to enter MODE selection Till to below LED display is shown in LED panel and the laser will ...

Страница 19: ... ILDA control panel Remote Instruction Button Function Description ON OFF In REM mode to turn ON OFF laser In any standalone mode excepted SLA mode pressing 2 seconds for activate REM mode AUTO AUTO running show MUSIC SOUND activated show The blue music LED indicator is flashing when sound signal is detected Sound Sensitivity In Sound Activated Show press MUSIC B 1 9 to do sensitivity setting 9 is...

Страница 20: ...tention Any control or setting in remote will be saved in ram until the system is rebooted The system is in AUTO show in any first remote mode after reboot DMX Channels Chart CHANNEL VALUE FUNCTION CH 1 MODE 000 020 Laser OFF 021 040 AUT 041 060 AU1 061 080 AU2 081 100 AU3 101 120 SOU 121 140 SO1 141 160 SO2 161 180 SO3 181 200 AUP 201 220 SOP 221 255 DMX MODE CH 2 GROUP 000 051 1 Group Patterns 0...

Страница 21: ...255 Clipping Speed CH 6 ZOOMING 000 127 100 5 fixed pattern zoomed 128 169 Zooming IN 170 209 Zooming OUT 210 255 Alternately Zooming CH7 ZOOM SPEED 000 255 Fast to Slow CH 8 Y AXIS ROLLING 000 127 0 359 degree fixed Y axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling CH 9 ROLL SPEED 0 255 Fast to Slow CH 10 X AXIS ROLLING 000 127 0 359 degree fixed X axis rolled 128 191 Clockwis...

Страница 22: ...VING 000 127 128 different fixed position on X axis 128 191 Clockwise moving 192 255 Anticlockwise moving CH 15MOVE SPEED 0 255 Fast to Slow CH 16 X AXIS MOVING 000 127 128 different fixed position on Y axis 128 191 Clockwise moving 192 255 Anticlockwise moving CH 17MOVE SPEED 0 255 Fast to Slow ...

Страница 23: ...USER MANUAL 22 PATTERN LIST ...

Страница 24: ...MX Channels Measurement N Weight AC100 240V 50 60Hz 250V 1A Slow Blow 20mm Glass 15W 20 Audio Sound Activated 40mW 532nm Green CW 100mW 650nm Red CW Class 3B EN60825 1 2007 10 40 3 pins XLR Male Female Max 17 channels See picture below 1 5Kg Every information is subject to change without prior notice The availability of particular products may vary by region Please check with the dealer ...

Страница 25: ... B2 Ger man Accident Prevention Insur ance Association regulation B2 Laser safety officers must have the requisite qualification G An approval is required for class 3B lasers WARNING The accessible laser radiation is hazardous to the eye also frequently to the skin It is haz ardous to look directly into the beam of class 3B lasers It may be possi ble to view a beam safely via a diffusing reflector...

Страница 26: ...enne enhed er klassificeret som en class 3B laser G Når en class 3B laser benyttes skal en sikkerhedsansvarlig person skrift ligt være udpeget og denne skal altid være tilstede under brugen af lase ren BGV B2 Den sikkerhedsansvarlige person skal have den nødvendige uddan nelse G En class 3B laser kræver særlig god kendelse fra myndighederne Laserstråling Undgå kontakt med laserstrålerne Class 3B l...

Отзывы: