background image

USERÕS MANUAL

QUESTIONS?

As a manufacturer, we are com-
mitted to providing complete
customer satisfaction. If you
have questions, or find that there
are missing or damaged parts,
we will guarantee complete satis-
faction through direct assistance
from our factory. 

TO AVOID UNNECESSARY
DELAYS, PLEASE CALL DIRECT
TO OUR TOLL-FREE CUSTOMER
HOT LINE. The trained techni-
cians on our customer hot line
will provide immediate assis-
tance, free of charge to you.  

CUSTOMER HOT LINE:  

1-800-999-3756

Mon.ÐFri., 6 a.m.Ð6 p.m. MST

Model No. IMHS80081
Serial No. 

Write the serial number in the space
above for reference.

CAUTION

Read all precautions and instruc-
tions in this manual before using
this equipment. Save this manual
for future reference.

Serial Number Decal

¨

Summary of Contents for IMHS80081

Page 1: ...NECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon ÐFri 6 a m Ð6 p m MST Model No IMHS80081 Serial No Write the serial number in the space above for reference CAUTION Read all precautions and instruc tions in this manual before using th...

Page 2: ...not extend to any product or damage to a product caused by or attributable to freight damage abuse misuse improper or abnormal usage or repairs not provided by an ICON authorized service center products used for commercial or rental pur poses or products used as store display models No other warranty beyond that specifically set forth above is authorized by ICON ICON is not responsible or liable f...

Page 3: ... is not in use 13 Keep all chemicals away from children and pets 14 The pH and chemical balance of the water must be maintained as explained in this man ual see page 13 Failure to do so may cause injury to users or damage to the spa jet unit and will void the warranty 15 The water pump in the spa jet unit must be primed before you use the hydrotherapy spa the first time You must also prime the pum...

Page 4: ... harmed 28 DANGERÑTo reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia a dangerous condition which occurs when the internal body temperature rises several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia are nausea dizziness drowsiness and fainting Effects include a lack of awareness inability to per ceive heat or danger ...

Page 5: ... hydrotherapy spa Locate the labels and familiarize yourself with this information The label on the side of the spa jet unit is an adhesive decal If this decal is missing or if it is not legible please call our Customer Service Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time to order a replacement decal Apply the decal in the location shown ...

Page 6: ...ou have addition al questions please call our Customer Service Department toll free at 1 800 999 3756 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please note the product model number and serial number before calling The model number is IMHS80081 The serial number can be found on a decal attached to spa jet unit see the front cover of this manual B...

Page 7: ... there is room around the hydrothera py spa to permit servicing of the unit The diame ter of the tub is 69Ó You should allow for this size plus the size of the spa jet unit when choosing the location 8 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the hydrotherapy spa If you set up the hydrotherapy spa outside 1 You...

Page 8: ... valve on top of the Inflatable Spa Liner 9 Use the air pump to fill the cushion on the top of the Inflatable Spa Liner with air 3 Be sure that the flap on the Fabric Spa Surround 8 is on the outside of the Fabric Spa Surround and Side Panels 1 2 Insert the Inflatable Spa Liner 9 into the Fabric Spa Surround Align the valve in the Inflatable Spa Liner with the hole in the Fabric Spa Surround and t...

Page 9: ...ntil the jet and filter openings on the Spa Jet Unit 13 are covered with water Do not fill the RENEW 800 more than 20Ó deep with water After the RENEW 800 is full you must prime the Spa Jet Unit 13 before using the hydrotherapy spa see PRIMING THE SPA JET UNIT on page 10 6 Insert the Support Ball 4 into the mesh pocket on the underside of the Spa Cover 11 See inset drawing A Insert the inflation t...

Page 10: ...rned on Note The first time the power cord is plugged in the spa jet unit will turn on automatically When connecting the power cord plug the power cord directly into a grounded circuit capable of carrying 15 or more amps No other appliance should be on the same circuit Replace the power cord immediately if it becomes damaged The power cord is equipped with a Ground Fault Circuit Interrupter GFCI l...

Page 11: ...he water to circulate for a while you should remove the spa cover and add 1 3 of the ÒBromine BaseÓ bottle and 1 3 of the ÒNon chlorine ShoxÓ bottle to the water in the spa Allow the water to circulate for five min utes You should now test the pH level of the water Use the included test strips to check the pH of the water Refer to the instructions on the test strip pack aging to see how to use the...

Page 12: ... the amount of air that is in the spa jet system during operation If the control is turned to the left the amount of air flowing through the jets will increase If the control is turned to the right the amount will decrease Thermostat Controls the temperature of the water The water heats at about 1 7 F an hour with the cover on The thermostat can be set to heat the water from 70 F to 104 F Use a me...

Page 13: ...ge 11 Additional chemicals can be purchased at a pool and spa supply store CAUTION The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous Always follow these basic guide MAINTENANCE ment by removing the filter cover and the two filter cover screws and then pulling the filter from the spa jet unit The spa jet unit features an automatic filter cycle and...

Page 14: ... store chemicals in a cool dry place MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of relative acidity or alka linity in the water It is measured on a scale of 1 to 14 Pure water has a value of 7 which is neutral Any value above 7 is alkaline and any value below 7 is acidic You should maintain a slightly alkaline pH level between 7 2 and 7 8 in the hydrotherapy spa Severe problems c...

Page 15: ... pump again and fully tighten the primer cap see PRIMING THE SPA JET UNIT on page 10 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a When you press the on off button once the spa jet unit will run at low speed heating the water Press the button again and the spa jet unit will run at high speed filtering the water Press the button a third time and the spa jet unit will shu...

Page 16: ...iday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please be pre pared to give the following information when calling 1 The MODEL NUMBER of the product IMHS80081 2 The NAME of the product IMAGE RENEW 800 3 The SERIAL NUMBER of the product see the front cover of this manual 4 The KEY NUMBER and DESCRIPTION of the part s see the PART LIST EXPLODED DRAWING attached to the c...

Page 17: ... Keep Nut 25 1 Electronic Control 26 1 Primer Housing 27 1 Headrest w Fasteners 28 4 1 4Ó Nut 29 1 Heat Control Nut 30 4 5 16Ó Rubber Washer 31 4 5 16Ó Washer 32 1 On Off Switch Bracket Key No Qty Description 33 1 Rubber Damper 34 1 Wire Harness 35 1 Air Control Knob 36 1 On Off Switch Assembly 37 1 Thermostat Knob 38 1 Primer Cap 39 15 8 x 1 2Ó Screw 40 1 Console Overlay 41 1 On Off Wire Harness ...

Reviews: