background image

TNS-101 

(Ref. 5114)

FTA or MultiCrypt DVB-T 

 IP  Streamer   —   Common Interface

Configuration and Settings

User Manual

Television on IP Networks

Summary of Contents for TNS-100

Page 1: ...TNS 101 Ref 5114 FTA or MultiCrypt DVB T IP Streamer Common Interface Configuration and Settings User Manual Television on IP Networks ...

Page 2: ...ration and Setting of the TNS 101 Streamer Module June 2009 Revision A IKUSI Ángel Iglesias S A Paseo Miramón 170 20009 San Sebastián SPAIN Tel 34 943 44 88 00 Fax 34 943 44 88 11 www ikusi com User Manual EN ...

Page 3: ...onfiguration 11 General Report 12 Chapter Two TNS 101 Streamer Settings 13 Input Settings 14 Output Settings 15 17 SAP Channel Settings 18 CAM User Menu 19 SNMP Cofguration 20 21 Chapter Three TNS 101 Streamer Status Information 22 Status Information 23 Chapter Four TNS 101 Streamer Reports 24 Input Services 25 Output Streams 26 System Logs 27 3 ...

Page 4: ...ed from a CFP module Characteristics Input 1 DVB T transport stream MPTS Output up to 8 simultaneous IP encapsulated services TV programmes with individual multicast addresses Information filtering of DVB tables UDP RTP transmission protocols Web interface for configuration and setting Alarm information SNMP agent SAP SDP protocols that facilitate automatic service selection on the user s STB and ...

Page 5: ...Chapter One Configuration of the TNS 101 Streamer In this Chapter Configuration Save Restore General Report 5 ...

Page 6: ... may or may not be incorporated into the output data stream On the left of this screen are the menus that access all of the programme s functionalities Click on the General menu on the left of the screen to display a dropdown list containing the 3 options Configuration Save Restore and General Report Click on Configuration The Configuration window will appear Identification The identification card...

Page 7: ...r the postcode of the installation site if required Installer The installer s identification details can be entered here Contact Then enter their contact details telephone number email Installation date The date on which the streamer module was installed can be entered here Click on the Save button at the bottom of the window to store the information on the streamer module this information is then...

Page 8: ...by consulting the DHCP server management system IP Address Enter the IP address that you wish to assign to the streamer This address must fall within the range of local network addresses Network mask Enter the local network mask Default gateway Enter the IP address of this gateway This information is only required if you want the streamer to access Internet Primary DNS server Enter the primary ser...

Page 9: ...o not know the old password i e the password used to access the current configuration session you must perform a Password Reset as explained in the Installation and Access manual Following this reset the program password will be the default password admin IMPORTANT When you perform a password reset the IP address assigned to the streamer on the Network card previous page automatically changes to t...

Page 10: ...onsible for its basic operation Figure 1 6 Update Firmware card of the Configuration window WARNING The firmware update file will have been previously stored on the PC hard drive You can download it from http www ikusi com Click on Browse and select the firmware update file from the hard drive When the file name is in the box click on Start The new firmware will be installed on the streamer and th...

Page 11: ... Save configuration Select the option in the window and click on Start A window is displayed which allows you to select the destination folder for the data file for the current streamer configuration Restore Configuration Select this option in the Save Restore window Figure 1 7 and click on Start The Restore Configuration window is displayed Fig 1 8 Click on Browse and select the file containing t...

Page 12: ...eport window is displayed This window provides complete information on the TNS 101 module not only regarding the configuration described in the previous pages but also in relation to the current settings parameter values and operational status The information contained in this window can be printed by clicking on the Print page button at the bottom of the screen General Report ...

Page 13: ...Chapter Two TNS 101 Streamer Settings In this Chapter Input Settings Output Settings SAP Channel Settings CAM User Menu SNMP Configuration 13 ...

Page 14: ... module has synchronised or not with the input signal Input Frequency MHz Enter the central frequency of the input channel The operation band is 174 230 MHz and 470 862 MHz Bandwidth It is the channel bandwidth Select 7 or 8 MHz from the drop down list Hierarchy This parameter refers to the hierarchy of the bit stream s channel coding and modulation According to it select High Priority or Low Prio...

Page 15: ...ed at the correct speed for its projection in real time Time To Live Is a parameter used to restrict the stream multicasting range A number between 1 and 255 is entered in this box Each time that an IP stream passes through a router the TTL is reduced by one unit The stream will be rejected by any router when the TTL value is reduced to zero QoS Quality of Service The drop down list offers five di...

Page 16: ... services including different details name type identifier main PID provider Highlighted in orange are those services which are already configured as IP streams seen in the display table in the Output window and highlighted in green are those which are not yet configured To add a stream to the display table select the button for the corresponding service in the first column The line will be highli...

Page 17: ... s set top box or reproducer if the device supports SAP SDP protocol The name that the service has on the input transport stream is the default name Channel Number Enter the order number you want to assign to the service on the subscriber s set top box or reproducer if the device supports SAP SAP Group Select from the drop down menu the SAP group to which you want to link the service The group wil...

Page 18: ... an EPG type program guide SAP Activated Check the box if you wish to transmit the program guide SAP IP address This data cannot be changed It is the IP address assigned to the streamer module on the Network tab in the Configuration window page 8 Username The name entered will be transmitted on the SAP SDP channel Group As above Time interval between SAP announcements Introduce the time interval i...

Page 19: ... the example to accede to the Card option you must press the key 1 of the keyboard number 1 will be shown in the lower box see Figure 2 7 and next you must click on the Send button The window of Figure 2 8 appears This window besides to inform about the card serial number and the stored maturity level allows to change this level through the Change Maturity option via keyboard and Send button as ex...

Page 20: ... Identify CFP 702 Enter a name for the CFP 702 linked to the present streamer module Minimum Alarm Duration Enter the minimum duration in seconds of an alarm event so that it be considered as such by the SNMP manager Send Traps Continuously Tick the box if you want that to an alarm event the related trap be sent repeatedly to the manager If this box is ticked the two next ones are disabled Trap Se...

Page 21: ...ing a summary trap with the current status of the most outstanding parameters Time between Sendings This box is enabled only if you ticked the previous one Enter the desired time in seconds to pass between summary trap sendings VAUX 12V COFDM IN CONTROL VAUX 12V CONTROL VAUX 12V CONTROL VAUX 12V CONTROL VAUX 12V CONTROL VAUX 12V CONTROL Link Act LAN Link Act LAN Link Act LAN Link Act LAN Link Act ...

Page 22: ...Chapter Three TNS 101 Streamer Status Information In this Chapter Status Information 22 ...

Page 23: ...chronisation or not with the input signal In cases where there is not synchronisation check the settings made in the Input Settings page 14 CAM Indicates whether the CAM module works properly or either it doesn t work properly or no CAM is installed BER Expresses in scientific notation the channel BER value for the input signal C N dB The value in dB of the carrier noise ratio of the input signal ...

Page 24: ...Chapter Four TNS 101 Streamer Reports In this Chapter Input Services Output Streams System Logs 24 ...

Page 25: ...he full information on each of the services contained in the DVB T input transport stream In particular it specifies the values of the following parameters for each service Name of the service Type SID service identifier PID of the main stream Service Provider PID Type and Language of each one of the elemental streams associated with the main stream Figure 4 1 Input Services Window Input Services ...

Page 26: ...shows the following details ON OFF whether the stream is incorporated or not in the output data stream IP Stream multicast address SID service identifier PID of the main stream Name of the service Type Total output bandwidth in Mbps SAP ID name with which the service is announced on the subscriber s receiver Service Provider PID Type and Language of each one of the elemental streams associated wit...

Page 27: ...27 System Logs Click on the Reports menu on the left of the general program screen and click again on the System Logs option The System Logs window will appear Figure 4 3 System Logs window System Logs ...

Page 28: ...IKUSI Ángel Iglesias S A Paseo Miramón 170 20009 San Sebastián SPAIN Tel 34 943 44 88 00 Fax 34 943 44 88 11 www ikusi com ER 0149 1996 ...