background image

–  1  –

Q u i c k   S t a r t   G u i d e

Unboxing

After opening the box, you will find…

MetroLinq™ (ML-60-35 or ML-60-19)

Bracket Kit

POE Power Supply

Power Cable

Tools/Items Required

13 mm Socket Wrench

Flat-Head Screwdriver

Ethernet Cables

(Optional) Alignment Scope ICC-SCOPE-9x50

For helpful training and user-case information, please go to 

ignitenet.com/support

Assembly

The MetroLinq™ bracket is designed for wall and pole mounting 
(25 mm - 75 mm pole diameter). Choose what is best for your 
location and select hardware accordingly.

Power Up

Welcome to MetroLinq™

Interference-Free Gigabit Wireless

Ensure all four position-locking bolts are tight before 

installing.

1

Install the bracket onto MetroLinq™ using four M8 bolts, 

lock washers, and flat washers.

Connect an Ethernet cable from the MetroLinq™ WAN port 

(right-side RJ-45) to the POE port on the power supply.

Connect Ethernet cable from the “LAN” port on the power 

supply to your LAN device.

Connect the power cord to a nearby AC power source.

2

1

2

3

MetroLinq 60

E042016-CS  15020000xxxxA R01

MetroLinq

 

Outdoor 60 GHz PTP + 5 GHz

ML-60-35 / ML-60-19

www.ignitenet.com

Summary of Contents for ML-60-35

Page 1: ...what is best for your location and select hardware accordingly Power Up Welcome to MetroLinq Interference Free Gigabit Wireless Ensure all four position locking bolts are tight before installing 1 In...

Page 2: ...l position Re tighten bolt 4 Loosen the vertical fine tune adjustment bolt 1 Use fine tune bolt A to optimize the vertical position Re tighten bolt 1 Initial alignment should be based on optical or vi...

Page 3: ...needs to be installed by a qualified person who has RF and related rules knowledge The general user shall not attempt to install or change the settings 2 Installation location The product shall be in...

Page 4: ...or network and service supply not for spectrum Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny lesund Russian Federation None...

Page 5: ...e e Radio LAN device sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 1999 5 ES Slovenian Slovensko IgniteNet izjavlja da je ta radio LAN device v skladu z bistvenimi zahtevami in ostali...

Page 6: ...N RJ 45 Port 1000BASE T 60 GHz Radio IEEE 802 11ad 5 GHz Radio IEEE 802 11ac Radio Frequencies 5150 5250 MHz FCC 5725 5850 MHz FCC 5745 5825 MHz China 5180 5320 MHz ETSI 5500 5700 MHz ETSI 58 32 64 80...

Page 7: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 8: ...in normal operation condition to meet regulatory RF exposure requirement 3 External antenna Use only the antennas which have been approved by the applicant The non approved antenna s may produce unwa...

Page 9: ...pas tre co localis s ou fonctionnement en association avec une autre antenne ou transmetteur This radio transmitter IC 3857A ML6035G3 has been approved by Industry Canada to operate with the antenna...

Page 10: ...p cifi e pour l exploitation point point et non point point selon le cas Users should also be advised that high power radars are allocated as primary users i e priority users of the bands 5250 5350 MH...

Reviews: