background image

VOGUE 

SYSTEM 

GEN2

 

S15  S18  S26  S32

USER GUIDE

When replacing any part on this appliance, use only spare parts that you can be

assured conform to the safety and performance specification that we require. 

Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers.

January 2017     UIN 216174 A02

Summary of Contents for Vogue S15

Page 1: ...ny part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been cle...

Page 2: ...2...

Page 3: ...ED AFTER EACH SERVICE Ideal Boilers is a member of the Benchmark scheme and fully supports the aims of the programme Benchmark has been introduced to improve the standards of installation and commissi...

Page 4: ...t be installed by a Gas Safe Registered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordance with...

Page 5: ...en supervision or instructions concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance In cases of rep...

Page 6: ...R OR ROOM THERMOSTAT OFF 39O C TO CYLINDER ON 39 C min max on off A B H D A Boiler Status B Burner On indication Legend C Hot Keys D Central Heating Temp Control E On Off Control F Pressure Gauge G G...

Page 7: ...aller 01482 498663 EXIT RESTART Reset the boiler and the ignition sequence will be repeated OPERATION Central Heating With the external heating controls calling for heat the off on control E set to on...

Page 8: ...rature for all outside weather conditions TO SHUT DOWN THE BOILER Set the off on switch E to off TO RESTART THE BOILER Repeat the procedure detailed in To light the boiler page 7 Set the off on contro...

Page 9: ...he filling loop Press RESTART hot key on the control panel to restart the boiler If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Instal...

Page 10: ...To unblock a frozen condensate pipe 1 Follow the routing of the plastic pipe from its exit point on the appliance through its route to its termination point Locate the frozen blockage It is likely tha...

Page 11: ...LEAKS WITH A NAKED FLAME CLEANING For normal cleaning simply dust with a dry cloth To remove stubborn marks and stains wipe with a damp cloth and finish off with a dry cloth DO NOT use abrasive cleani...

Page 12: ...ugh the following guide to identify any problems external to the boiler prior to requesting a service engineer s visit Should the problem be found to be other than with the appliance we reserve the ri...

Page 13: ...tat are switched on Check batteries in programmable room stats Ensure that the mains supply to the boiler is switched on and that no trips have operated in the consumer unit FAULT FINDING If a fault o...

Page 14: ...to the on position to switch the boiler on MENU OFF Indicates that the boiler is either heating the radiators or the hot water cylinder MENU 60O C ON Indicates that either the timer is off or the room...

Page 15: ...Boiler is providing central heating and radiator temp is 60 C Indicates that central heating timer or room stat is off Indicates that the boiler is switched off Move off on switch E to the on position...

Page 16: ...C and the boiler is running to protect itself from frost damage MENU BOILER FROST PROTECTION ACTIVE SWITCH OFF TEMPERATURE 19O C Indicates that a service is due To reset the service time refer to page...

Page 17: ...entral Heating frost protection turn the On Off switch E to the Off position This screen will be shown MENU OFF To switch the boiler on turn the On Off switch into the On position E This screen will b...

Page 18: ...MENU and the following screen will be displayed Press select and a screen similar to the following will be displayed Press EXIT twice to return to normal operation EXIT SELECT MENU SERVICE COMPANY NAM...

Page 19: ...the following screen is displayed Press SELECT and the following screen is displayed Press MENU SHOW EFFICIENCY LEVEL HOT WATER PREHEAT ON OFF SERVICE COMPANY PHONE NUMBER SERVICE COMPANY NAME MAX OF...

Page 20: ...n Hull HU5 4JN Tel 01482 492251 Fax 01482 448858 Registration No London 322 137 Ideal Boilers Ltd pursues a policy of continuing improvement in the design and performance of its products The right is...