background image

TEMPO
IDEALFORM PLUS+ 
SHOWER BATH

Installation Instructions

Please pass on to user

5041 09/13

EE75408967

5041 Tempo Baths:Layout 1  10/09/2013  10:24  Page 1

Summary of Contents for TEMPO IDEALFORM PLUS+

Page 1: ...TEMPO IDEALFORM PLUS SHOWER BATH Installation Instructions Please pass on to user 5041 09 13 EE75408967 5041 Tempo Baths Layout 1 10 09 2013 10 24 Page 1...

Page 2: ...re the water feeds and waste connection points are positioned appropriately for the installation Care should always be taken when drilling into walls and floors to avoid any sunken wires or pipes The...

Page 3: ...B A Ref Leg Support Beam Bath Description 2 1 Qty C Leg 2 D Nut 4 E Foot 140mm Long 2 F Foot 120mm Long 2 G Plastic Leg Adjuster 2 or BATH COMPONENTS 5041 Tempo Baths Layout 1 10 09 2013 10 24 Page 3...

Page 4: ...Ref G 2 H3 Wall Plugs Small 2 Wall Plug Screw Small 2 H5 Wall Plug Large 4 H6 Wall Plug Screw Large 4 Side Wall Bracket Screw 2 J Corner Wall Bracket 1 I Wall Support Bracket 2 K Side Wall Bracket 2 1...

Page 5: ...rew Metal Panel Clip Plastic Panel Clip End Panel Front Panel 5 8 4 5 1 2 2 1 or Ref Description Qty FRONT PANEL Sold supplied separately END PANEL Sold supplied separately Panel Clip No 6 x 12 Pan He...

Page 6: ...ef B Ref F Ref C Ref D Ref F Ref G Ref H2 Ref O Ref A Ref O Ref P Ref L Ref F Ref D Ref F Ref C Ref E Encapsulated baseboard Ref B Ref E Ref H2 Ref H1 Ref G Ref P Ref O 3 Ref E Ref E Figure 2 BATH ASS...

Page 7: ...Cranked leg Left hand shown Ref L Figure 3 Cranked leg Left hand shown Figure 4 5041 Tempo Baths Layout 1 10 09 2013 10 24 Page 7...

Page 8: ...pace 510 Ref H3 Ref I Ref J Ref J Ref H4 Figure 5 pre drilled hole Ref H5 Ref H5 Ref H6 Ref J Ref K Ref K Ref H6 Ref H1 Ref H7 Ref H7 bath rim Figure 6 5041 Tempo Baths Layout 1 10 09 2013 10 24 Page...

Page 9: ...onto feet NOTE If the bath is to be installed at a lower height than normal then provision for the waste trap to be recessed into the floor may be necessary Also the bath panel s will need to be cut d...

Page 10: ...floor Remove panel and fix the plastic panel clips onto the floor wall s Figure 7 The front of the block at the floor should be 3mm back from the marked line Note The front panel may touch the suppor...

Page 11: ...preferably whilst the water is running out and the bath is still warm The film of insoluble soap products body fats and grime which will otherwise harden on the side of the bath is easily removed at t...

Page 12: ...rs This covers products in domestic use by the consumer and not commercial or business use All Ideal Standard products must be installed used and cared for in line with our fixing instructions local w...

Reviews: