background image

 
 

PRX-SAM 

 

Standalone Proximity Reader Interface 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation Manual 

 

1.0 Introduction 

 
Thank you for choosing the Nano Prox Series of 
Standalone Proximity Readers from Integrated Control 
Technology. The standalone interface allows management 
of the Nano Prox Series of Proximity readers using the 
Nano Prox software. Connection is made with RS232 and 
RS485 interfaces selectable using the on board 8 way dip 
switch. 
 

2.0 Configuration 

 
By default the standalone interface is shipped with no 
options enabled and needs to be set correctly for the 
desired operation. 

 
Configuration of the DIP switch settings MUST 
BE done with the power off. Setting conflicting 
switch settings may damage the PRX-SAM. 

 
Input Mode Operation 
Input Only Mode is selected by turning ON Switch 1 and 5 
and turning off all other switches. This allows a standard 
input configuration to be used with a Buzzer Control Input 
and an Alarm Output (Open Collector) 
 
RS232 Serial Communication Mode 
RS232 Serial Communication Mode is selected by turning 
ON Switch 2,3,6 and 7. This will allow the RS232 
communications to be wired to the P1 (Receive Data) and 
I3 (Transmit Data). 

 
The alarm output P1 is used for the transmit 
data in both the serial modes. The beeper will 
still be activated to signal a forced/open door. 

 
RS485 Serial Communication Mode 
RS485 Serial Communication Mode is selected by turning 
ON Switch 2,4,6 and 8. This will allow the RS485 
communications to be wired to the I3 (NA) and P1 (NB). 
 

If the PRX-SAM is located at the end of the 
RS485 communication cable run ensure that 
the EOL jumper is enabled. 

 

3.0 DIP Switch Configuration 

 
The following table shows the individual functions for the 
configuration DIP Switch. 
 

Switch 

Function 

Input Only Mode 

Serial Communication Mode 

3 RS232 

Mode 

4 RS485 

Mode 

Input Only Mode 

Serial Communication Mode 

7 RS232 

Mode 

8 RS485 

Mode 

 

4.0 Card Reader Connection 

 
The proximity reader and power supply is wired in to the 
terminal block on the bottom edge as shown below.  
 

 

 

Figure 1 – Card Reader Connection 

 

5.0 Input Mode Wiring Connection 

 
Input wiring allows the connection of standard inputs to 
the PRX-SAM for the door contact and REX (request to 
exit) button.  
 

 

 

Figure 2 – Input Only Mode 

 

6.0 RS232 Wiring Connection 

 
RS232 wiring allows the connection of the Nano Prox to 
the RS232 Serial port on a computer and the 
programming to be completed using the Nano Prox 
Software.  
 

 

 

Figure 3 – RS232 Connection 

 

EOL Jumper MUST be off when using RS232 

Reviews: