User Manual |

 

P1

 

 

 

 

 

 

 

 

 

 

 

 

 

ECL202/ECL202e 

Summary of Contents for ECL202

Page 1: ...www ibspe com User Manual P1 ECL202 ECL202e ...

Page 2: ...RS 5 5 1 LED RANGE INDICATOR 5 5 2 RESETTING OFFSET 5 5 3 SETPOINT BUTTON 5 6 ANALOGUE OUTPUT SIGNAL 6 6 1 INTERPRETING THE OUTPUT VOLTAGE 6 6 2 CHANGE IN GAP CALCULATION 6 7 REMOTE OFFSET AND SETPOINT 6 8 SETPOINT SWITCH OUTPUT 6 9 BANDWIDTH SELECTION ECL202 ONLY 6 10 MAXIMISING PERFORMANCE 7 10 1 EXTENSION CABLES 7 10 2 PROBE MOUNTING 7 10 3 UNGROUNDED TARGETS 7 10 4 MULTIPLE SENSORS 7 11 CONNEC...

Page 3: ... or 60 VDC All external connections must be SELV Safety Extra Low Voltage Use of the equipment in any other manner may impair the safety and EMI protections of the equipment 2 Helpful Technical Support Documents Online The IBS Precision Engineering s website has a large selection of technical documents TechNotes and Application Notes in the Technical Library These documents provide detailed descri...

Page 4: ...consists of driver electronics and a probe calibrated for a specific material and range The calibration information is detailed on a calibration certificate which is shipped with the system The ECL202 provides a linear analog voltage proportional to changes in the target position and a digital switched setpoint output with a user programmed switching setpoint 4 Quick start instructions 1 Connect t...

Page 5: ...not a reliable indication of the target position This function establishes a repeatable master point for reference measurements 1 Place good part in the measurement area 2 Position probe to center 20 of range center indicator LED 3 Press Offset button 4 All subsequent measurements indicate deviation from center of range 5 V 5 2 Resetting Offset Hold the Offset button for four seconds to remove any...

Page 6: ... buttons can be activated remotely Each remote input connects to an opto isolator The functions are activated by applying 15 24 V to the remote control input terminals Note Because the remote operation mimics front panel operation activating the Offset function for more than four seconds will restore factory default value for Offset 8 Setpoint switch output When the output voltage is more positive...

Page 7: ...asured Otherwise custom calibration will be required 10 3 Ungrounded Targets Ungrounded targets have the potential to inject noise into the sensor If the output is unusually noisy be sure the target is grounded On moving rotating targets this can be accomplished with a small metal brush or thin piece of metal which is connected to ground 10 4 Multiple Sensors When multiple sensors are used with th...

Page 8: ...t function 15 24 VDC Activates the function Remote Threshold Opto isolator input for Setpoint function Switch Contact 1 of switched output Open 30 VAC 60 VDC max Closed 250 mA max Switch Contact 2 of switched output Bottom Front Connector Power and Analog Output Power In Input Power Internally connected together Power Ground Power Ground Output Signal Ground Reference for output signal voltage Out...

Page 9: ...log Output Update Rate 15 μS Setpoint Switch Output Solid state switch closure On state 2 5 Ω 250 mA max Off state 30 VAC 60 VDC max Remote Setpoint and Offset Inputs 15 24 VDC to activate 3 7 mA Opto isolator inputs Driver Operating Environment 4 C 50 C IP40 Probe Operating Environment Standard Probes 25 C to 125 C IP67 High Temp Probes 25 C to 200 C IP63 Actual values depend on probe and range a...

Page 10: ... C U5 Probe 0 1 F S C U8 Probe 0 04 F S C U12 Probe U18 Probe U25 Probe U38 Probe U50 Probe Temperature Coefficient Probe Nonferrous U3 Probe 0 04 F S C Over 15 C to 65 C Temperature range U5 Probe 0 04 F S C U8 Probe 0 02 F S C U12 Probe 0 02 F S C U18 Probe 0 01 F S C U25 Probe U38 Probe U50 Probe Ferrous U3 Probe 0 04 F S C 15 C to 35 C 0 08 F S C U5 Probe 0 01 F S C U8 Probe 0 04 F S C U12 Pro...