Summary of Contents for inSentry-man-E210

Page 1: ...inSentry man E210 ...

Page 2: ...f Radio interference Characteristics of information Technology Equipment This device complies with the CISPR Class B standard EN 55024 1998 Electromagnetic compatibility Generic immunity standard Part1 Residential and light industry Safety Information To reduce the risk of fire or electric shock install the unit in a temperature controlled indoor area free of conductive contaminants Do not place t...

Page 3: ..._____________________ 23 3 1 Utilising the inSentry Home Page ______________________________________ 23 3 2 inSentry Monitoring _________________________________________________ 24 3 3 inSentry Management _______________________________________________ 27 3 4 inSentry History ____________________________________________________ 30 4 Monitoring inSentry via Java Monitor ____________________________...

Page 4: ...inSentry 1 2 Package Contents An inSentry box An EMD box Environment Monitoring Device A Magnetic Reed Switch RJ45 to DB9 Female serial cable for inSentry console operation RJ45 to RJ45 Male cable for connect to EMD communication port 12VDV Power adapter inSentry CD ROM containing inSentry MIB file for SNMP Network Management System NMS inSentry Quick Installation Guide inSentry User Guide in elec...

Page 5: ... configure the inSentry inSentry Quick Installation Guide gives detail on how to install and configure a inSentry using a Windows OS workstation inSentry User Guide gives more detail and information on installation and configuration of inSentry inSentry provides online help that gives additional instructions for administering a inSentry ...

Page 6: ...wo user provide contact devices to protect your critical equipment Configure inSentry functions from any client password protected Sets inSentry parameters from any SNMP management station or through Internet Browsers using HTTP forms and objects E mail notification feature E mail notification through SMTP via e mail client software a phone or alphanumeric pager when acceptable alarm limits are ex...

Page 7: ...ough a Web Browser 2 Connect the supplied straight through CAT 5 network cable from the inSentry s RJ45 connector labeled EMD 1 to the labeled 010101 port on the EMD NOTE If the configuration cable is still attached to the inSentry remove and store it for future use NOTE If the supplied straight through CAT5 network cable is not long enough for your application you may substitute a longer cable no...

Page 8: ...8 Pin Number Description Normally open closed 1 Contact 1 Return NC 2 Contact 1 Signal Input NO 3 Contact 2 Return NC 4 Contact 2 Signal Input NO Table 2 1 EMD Screw Terminal Pin Assignment ...

Page 9: ...m the inSentry s RJ45 connector labeled EMD 2 to the COM port on the PC see Figure 2 2 3 Set both the DIP switches of the inSentry to OFF position operating mode for configuration Figure 2 2 Serial cable connection of inSentry Configuring the inSentry 1 From a workstation running Microsoft Windows 9x Me NT4 0 2000 XP or later and click on the HyperTerminal icon of the accessory programs group see ...

Page 10: ... Hyper Terminal folders in the accessory programs group 2 Enter a name and choose an icon for the connection see Figure 2 4 Figure 2 4 New Hyper Terminal Connection 3 Select direct COM port connection see Figure 2 5 ...

Page 11: ... 6 Figure 2 6 Setup of the COM Port Parameters 5 Press the reset button at the back of the unit Wait for inSentry to boot up Messages will then are displayed on the screen see Figure 2 7 afterwards key in the password default password is admin The inSentry configuration utility main menu will be displayed on the screen Figure 2 7 inSentry Configuration Menu ...

Page 12: ...se parameters are listed below see Figure 2 9 Figure 2 9 System Group Configuration Menu No Function Description Example Remark 1 IP Address The inSentry IP address 192 168 1 100 2 Gateway Address The network default gateway 192 168 1 254 3 Network Mask The sub net mask setting 255 255 255 0 4 System Date inSentry internal Date dd mm yyyy 25 10 2001 5 System Time inSentry internal Time hh mm ss 09...

Page 13: ...HCP protocols Disable 5 TFTP Upgrade Control Enable disable the TFTP protocol for firmware upgrades through the local network Enabled 8 PING Echo Control Enable Disable inSentry to response to Ping request Enable 7 Telnet Control Enable disable the TELNET protocol Enable 9 HTTP Control Enable login and password request for HTTP access Enable 8 SNMP Control Enable login and password request for SNM...

Page 14: ... Mail Server As Administrator you may enter the IP Address or Hostname of a SMTP mail server that will be used to send email messages from the inSentry 2 User Account As Administrator you may enter the User Account of the mail server that will be used by the inSentry to login mail server to forward mails 3 User Password As Administrator you may enter the User Password of User Account 4 DNS IP Addr...

Page 15: ...EMD simple setting you can select the EMD 1 Setup or EMD 2 Setup to change the status and name of the EMD 1 and EMD 2 see Figure 2 13 2 14 2 15 Figure 2 13 EMD Configuration Group Figure 2 14 EMD 1 Configuration Group Figure 2 15 EMD 2 Configuration Group ...

Page 16: ...rk Management Access through TELNET or RS 232 is permitted only when using the Community Read Write password in Control Group Figure 2 16 Access Control Table NOTE The community strings entered in the Community String fields are visible only in the RS 232 connection The TELNET connection does not display the string An asterisk will be shown in the field NOTE If a NotAccess access right is associat...

Page 17: ...sole connection Reboot inSentry was not necessary unless you press 6 to ending the console connection and force inSentry reboot again As so far inSentry initialisation was completed NOTE If you want inSentry to load the factory configuration default you may press 5 to Reset Configuration To Default After completing all the settings press 0 to terminate the connection without starting inSentry agai...

Page 18: ...ress enter Proceed to Step 7 5 If there is no DHCP network service on the network contact your network administrator to get an IP address for you workstation that has the same network s address as the inSentry s default IP address The default IP address of inSentry is 172 17 XXX ZZZ where XXX and ZZZ is the last two pairs of the MAC address of inSentry in decimal 6 Type Telnet 172 17 XXX ZZZ comma...

Page 19: ...d 15 seconds Figure 2 18 Connecting the Ethernet Cable from the LAN Port of inSentry Manipulates network routing table in your workstation Normally the first time you use inSentry your workstation is unable to communicate to inSentry since they are not in the same IP subnet However you may use route add command to manipulate the network routing table in your workstation in order to carry out the i...

Page 20: ...work already installed 2 If there is no DHCP network service on the network contact your network administrator to get an IP address for you workstation that has the same network s address as the inSentry s default IP address The default IP address of inSentry is 172 17 XXX ZZZ where XXX and ZZZ is the last two pairs of the MAC address of inSentry in decimal 3 Start your Web Browser Enter the URL h...

Page 21: ...nSentry IP address 4 Enter the inSentry Gateway Address in the network 5 Enter the inSentry Subnet Mask of the network 6 Click the Set Values to save the settings 7 Select Date and Time from the inSentry Management of the main menu and enter the appropriate date and time information in the specified format 8 Select Set Values to save the date and time settings 9 Select inSentry Control to enable o...

Page 22: ...22 Figure 2 21 inSentry Control Screen ...

Page 23: ...y view the in EMD status it will not be able to perform any configuration on inSentry EMD See Pg 15 Access Control Table Setting and Pg 28 SNMP HTTP Access Control for details 3 1 Utilising the inSentry Home Page 1 Start your Web Browser and enter inSentry IP address 2 The inSentry home page will be shown on the screen 3 Select the help icon located at the bottom of each page for a detail descript...

Page 24: ... gives a snapshot of all parameters of inSentry and the parameters will be updated automatically every 5 seconds Figure 3 1 Comprehensive View Screen Detail Data This page gives the detail information of all parameters This page will refresh automatically every 5 seconds Figure 3 2 Detail Data Screen EMD 1 Setup This page let user to configure all necessary parameters of an EMD 1 Figure 3 3 EMD 1 ...

Page 25: ... Figure 3 4 EMD 1 Alarm Schedule Set Up Screen EMD 2 Setup This page let user to configure all necessary parameters of an EMD 2 Figure 3 5 EMD 2 Set up Screen EMD 2 Alarm Schedule This page let user to configure all necessary schedules of disabling the EMD 2 alarms User can disable the alarm by choosing the alarm type Figure 3 6 EMD 2 Alarm Schedule Set up Screen ...

Page 26: ...et all the inSentry information Figure 3 7 inSentry Identification Screen Alarm Table Select Alarm Table from the Monitoring on the main menu to get a table of the EMD alarms present This menu will refresh automatically Figure 3 8 Alarm Table Screen ...

Page 27: ...e manually Figure 3 9 Date and Time Screen inSentry Configuration This page lets the Administrator set the local network configuration parameters in inSentry Figure 3 10 inSentry Configuration Screen inSentry Control This page lets you enable or disable the communication protocols available in the inSentry and affect a restart and reset of the inSentry internal parameters Some of the items in this...

Page 28: ...inSentry parameters and itself Access Type to prevent someone arbitrarily change unless it login with Admin password Trap Receivers This page can hold a maximum of four entries It holds the list of the IP address of the Network Management Stations NMS which will receive the SNMP traps send by inSentry Figure 3 13 SNMP TRAP Screen Email Notification This page describing of inSentry email notificati...

Page 29: ... page describes the setting of External Links Up to four links can be set up by this page each link can configure to an external web page that user can easily to connect to related web pages Figure 3 15 External Links Screen ...

Page 30: ...t to delete the table entries Figure 3 16 History Log Data Screen NOTE To save the history log to a file in Microsoft Excel format go to the Clear Save Log Data sub menu and click on the link History Log under the Save Log Data title bar Extended Log This page gives a consolidated view of the EMD parameters taken over a period For each of the EMD parameters minimum maximum and the average values a...

Page 31: ...ht to delete the entries of the table Figure 3 19 inSentry Events Screen Clear Save Log Data This page lets the Administrator saves inSentry log data to a file in Microsoft Excel format Administrator is also able to clear specific log data or choose to clear the log data after saving the log data Figure 3 20 Clear Save Log Screen NOTE When you mouse click any one of the hyper link here while the C...

Page 32: ... button at the top right hand side on the inSentry Home Page a Java Monitor will be open in a separate window This monitor displays the EMD key parameters Temperature 1 Temperature 2 Humidity 1 Humidity 2 in graphic representation In addition this monitor has a function icon a status bar that can display the current EMD status and an alarm window that can display the current EMD alarms Figure 4 1 ...

Page 33: ...igure 4 2 Status Bar in Java Monitor The status bar displays the current status of the EMD unknown represent that the EMD is in normal condition If inSentry receives a status change of the EMD Alarm Windows When inSentry receives a change in the status of it own or of the EMD it displays a specific message in the Alarm Window This type of status change message is an alarm The Alarm Window displays...

Page 34: ...of the parameters to be displayed on the graph by checking the check box beside each parameter on the monitor screen and click the Refresh button Figure 4 3 EMD History Log Monitor Display Point Display the log interval on the graph Refresh Click the Refresh button after configures any setting on EMD History Log Monitor to take effect Reload Update the EMD history log monitor and reset the right d...

Page 35: ...he parameters to be displayed on the graph by checking the check box beside each parameter on the monitor screen and click the Refresh button Figure 4 4 EMD Extended History Log Monitor Display Point Display the extended log interval on the graph Refresh Click the Refresh button after configures any setting on EMD Extended History Log Monitor to take effect Reload Update the EMD history log monito...

Page 36: ...tocols NOTE If you do not enter the IP address of the workstation to the Access Control Table via Serial Port or Telnet or the SNMP HTTP Access Control via Web Browser in inSentry the SNMP NMS can only view the EMD status it will not be able to perform any configuration on inSentry EMD See Pg 15 Access Control Table Setting and Pg 28 SNMP HTTP Access Control for details 5 2 SNMP Trap Receivers Set...

Page 37: ...ous serial ports LAN Chip Auto Sense 10 100Mbps Fast Ethernet controller Network Connection 10 100TX RJ 45 jack connector RTC EPSON 4543 Network Protocol SNMP over UDP IP HTTP over TCP IP ARP RARP TFTP and ICMP Supported MIB RFC1628 inSentry MIB Operating Temperature 0 40 C Operating Humidity 10 80 Power Input 12V DC unregulated Power Consumption 3 0 Watts Maximum Size 138 mm x 88 mm x 30mm L x W ...

Page 38: ... ON ON Manufacture Diagnostic Mode 2 ON OFF Reserved 3 OFF ON Reserved 4 OFF OFF Operating Mode LED Indicator LED definition No Traffic LED Status LED Function Mode 1 ON Flashing 1 3sec Normal operation 2 Flashing 1sec Flashing 1 3sec Ethernet traffic 3 OFF Flashing 1 3sec Ethernet disconnect 4 Two LED cross Flashing Two LED cross Flashing Auto Diagnostic Mode 5 OFF Flashing 1sec Serial Upgrade Mo...

Page 39: ... 4 BLUE 5 5 WHITE BLUE 6 6 GREEN 7 7 WHITE BROWN 8 8 BROWN NOTE Cable length not to exceed 20m 65 6ft The Cable for EMD 2 port of inSentry PC cable RJ45 DB9 Female Description 1 Not connected 3 2 Received Data from PC 4 5 Signal Ground 5 Case GND Chassis Ground 6 3 Transmitted Data to PC 8 Not connected NOTE Pins 2 and 7 of the RJ45 connector are connected internally ...

Page 40: ...atible with Windows95 98 Me Windows NT 3 51 4 0 2000 XP and higher 1 Sensor Device List Displays the addresses of the inSentry present in the local network 2 Discover Search for the inSentry on the local network 3 Add Lets you add the IP address of a inSentry to the UPS List manually 4 Modify Lets you modify the parameters of the inSentry selected in the inSentry List 5 Upgrade Sends the program l...

Page 41: ...cute the following command line tftp tftp binary tftp connect host tftp put filename upgrade password username where binary Binary data download mode host inSentry IP address Example 172 168 1 18 put PUT command filename Name of the file containing the firmware image Example mnt floppy inSentry100 bin upgrade Upgrade key word Separator characters password username User Name and Password for read w...