background image

     

RCM-GW Gateway Unit 

First Step Guide   

First Edition

 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to   
this First Step Guide to ensure correct use. 
This Instruction Manual is original.

 

 
 
 
 

  Using or copying all or part of this Instruction Manual without permission is prohibited. 

  The company names, names of products and trademarks of each company shown in the sentences are registered 

trademarks. 

 

Product Check 

A standard configuration of this product is comprised of the following parts. 
If you find any fault in the contained model or any missing parts, contact us or our distributor. 

1. Parts 

No. 

Part Name 

Model 

Remarks

Controller Main Body 

Refer to “How to read the model plate” and 
“How to read the model”. 

 

Accessories 

Fieldbus 
Connector 

DeviceNet type 

SMSTB2.5/5-ST-5.08AU 
(Supplier : PHOENIX CONTACT) 

 

CC-Link type 
PROFIBUS type  Prepare Dsub 9-pin (female) connector. 

 

SIO Communication 
Connector Plug 

MC1.5/6-ST-3.5 
(Supplier : PHOENIX CONTACT) 

Applicable Cable Size 
0.3mm

(AWG22) 

Power Supply Input 
Connector Plug 

MC1.5/4-ST-3.81 
(Supplier : PHOENIX CONTACT) 

Applicable Cable Size 
1.25mm

(AWG16) 

Terminal 
Resistance 

DeviceNet type 

Please prepare separately 

121



1

    1/4W 

CC-Link type 

130

1/2W, 110

1/2W    enclosed one unit 

each 

 

PROFIBUS type 

Built-in 
(selected on terminal resistance switch) 

 

First Step Guide 

 

 

Instruction Manual (DVD) 

 

 

Safety Guide 

 

 

2. Instruction Manuals related to this product, which are contained in the Instruction Manual 

(DVD). 

No. 

Name 

Manual No.

DeviceNet Gateway Unit RCM-GW-DV Instruction Manual 

ME0168

CC-Link Gateway Unit RCM-GW-CC Instruction Manual 

ME0169

PROFIBUS Gateway Unit RCM-GW-PR Instruction Manual

 

ME0177 

ACON-C/CG Controller Positioner Type Instruction Manual 

ME0176

ACON-SE Controller Serial Communication Type Instruction Manual 

ME0171

PCON-C/CG/CF Controller Positioner Type Instruction Manual 

ME0170

PCON-SE Controller Serial Communication Type Instruction Manual 

ME0163

SCON Controller Instruction Manual 

ME0161

ERC2 Actuator with integrated Controller Instruction Manual (SIO type) 

ME0159 

3. How to read the model plate 
 

 

 

 

 

4. How to read the model 

 

• 

R C M - G W - D V  :  D e v i c e N e t   G a t e w a y   U n i t  

• 

R C M - G W - C C  :  C C - L i n k   G a t e w a y   U n i t  

• 

R C M - G W - P R  :  P R O F I B U S   G a t e w a y   U n i t  

 

 

 

 

 

 

 

 

 

Basic Specifications 

1. RCM-GW-DV 

Item 

Specification

DeviceNet ty

pe

 

Communication Protocol DeviceNet2.0 (certified interface)
For Communication 

Master/Slave Connection 

Bit Strobe
Polling
Cyclic

Baud Rate 

500k/250k/125kbps

Communication Cable 
Length 

(Note 1)

 

Baud Rate 

Max. Network Length

Max. Branch Line 

Length

Total Branch Line 

Length

500kbps

100m

6m 

39m

250kbps

250m

78m

125kbps

500m

156m

(Note) When DeviceNet dedicated thick cable is used

Number of Occupied Nodes 1 node
Communication Power 
Supply 

Voltage 24V DC

10% Current Consumption 60mA Externally Supplied (Supplied from 

DeviceNet communication cable side)

Communications Cable DeviceNet dedicated cable

Note 1  Refer to the instruction manuals for the master unit and the mounted programmable logic controller (stated as PLC 

from now on) when a T-junction communication is to be conducted. 

2. RCM-GW-CC 

Item 

Specification

C

C

-Li

nk type

 

Communication Protocol CC-Link   Ver1.10/Ver2

(Note 1)

Baud Rate 

10M/5M/2.5M/625k/156kbps

Communication System

Broadcast polling system

Synchronization System Frame synchronization system
Transmission Path 
Format 

Bus format (EIA    RS485 conformance    3-line type) 

Error Control System 

CRC (X

16

 

 X

12

 

 X

5

 

 1)

*1

 

Number of Occupied Stations Remote Device Station   [Refer to Field Network Wirings and Settings Section]
Communication Cable 
Length 

(Note 2)

 

Baud Rate

10Mbps

5Mbps

2.5Mbps

625kbps

156kbps

Total Cable 

Length

100m 

160m 

400m 

900m 

1200m 

Communications Cable CC-Link dedicated cable

Note 1  When the host CC-Link master unit is Ver.1, the available RCM-GW-CC is limited to Ver.1.10. Even if the host CC-Link 

master unit is Ver.2, RCM-GW-CC Ver.1.10 is connectable, but the available functions are limited. 
[Refer to 5. Operation Modes and Main Functions [2] RCM-GW-CC or Instruction Manual (DVD)] 

Note 2  Refer to the instruction manuals for the master unit and the mounted programmable logic controller (stated as PLC 

from now on) when a T-junction communication is to be conducted. 

*1 

CRC : Cyclic Redundancy Check    It is a data error detection method often used for the synchronous transmission 

3. RCM-GW-PR 

Item 

Specification

PROFIBUS ty

pe

 

Communication Protocol PROFIBUS-DP (RS485 conformance)
Communication System

Hybrid System (Master-Slave System or Token Passing System)

Baud Rate 

9.6k to 12Mbps (Automatic Following to the Master)

Communication Cable 
Length 
(Type A Cable) 

Baud Rate

12/6/3Mbps

1.5Mbps 

500kbps 

187.5kbps 

93.75/45.45/

19.2/9.6kbps

Total Cable 

Length

100m 

200m 

400m 

1000m 

1500m 

Number of Occupied Nodes 1 node
Communications Cable

Type A Cable for PROFIBUS-DP (Standard EN50170)

4. Common Specifications 

Item 

Specification

Power Supply 

24V DC

10

 

Current Consumption 

MAX. 300

Heat Generation 

7.2W

Connectable Models 

ERC2, PCON-C/CG/SE, ACON-C/CG/SE, SCON

Number of Max. Controllable 
Axes 

16-axis (There is a limitation for RCM-GW-CC depending on the Operation Mode 

[Refer  to  5.  Operation  Modes  and  Main  Functions  [2]  RCM-GW-CC  or  Instruction 
Manual (DVD)])

Fo

Co

mmu

n

ica

tion 

Communication 
Protocol 

RS485 conformance 

Communication System Start-Stop Synchronization System   Half-Duplex Communication
Baud Rate 

230.4kbps

Error Control System 

Non parity bit, CRC

*1

Communication Cable 
Length 

Total Cable Length    100m or less 

Communications Cable

Twisted-pair shielded cable 
(Recommended : Taiyo Cabletec Corporation    K-SB/20276 

 Length [m]    2P 

 AWG22) 

Envi

ro

nm

en

Surrounding air 
temperature 

0 to 40

Surrounding humidity

85%RH or less (non-condensing)

Surrounding 
environment 

[Refer to Installation Environment section] 

Surrounding storage 
temperature 

10 to 65

Surrounding storage 
humidity 

90%RH or less (non-condensing) 

Vibration durability 

XYZ Each direction  10 to 57Hz Pulsating amplitude 0.035mm (continuous) 0.075mm (intermittent)

57 to 150Hz 4.9m/s

2

(continuous) 9.8m/s

2

(intermittent)

Protection class 

IP20

Cooling Method 

Natural air-cooling

Insulation Resistance 

Between power supply terminal and FG    500V DC    10M

 or more 

Product Life 

(Reference) 5 to 10 years: It varies significantly by the effects of the usage condition 
(especially temperature).

External Dimensions 

35W 

 178.5H 

 68.1D [mm] 

Weight 

Approx. 480g

*1 

CRC : Cyclic Redundancy Check    It is a data error detection method often used for the synchronous transmission 

 

5. Operation Modes and Main Functions 

Operation Mode can be selected on the mode switch located on the front panel. [Refer to Field Network 
Wirings and Settings Section] 

[1] RCM-GW-DV 

Main Functions 

Position Number Specification 

Mode 

Direct Numeric Specification 

Mode 

Command Specification Mode

Positioner 
Operation

Simplified Direct 
Value Operation

Position Data Direct 
Specification Movement 

× 

○ 

(Note 1)

 

○ 

Velocity and Acceleration Direct Setup 

× 

○ 

(Note 1)

 

(Note 1)

 

Pressing Operation 

○ 

○ 

(Note 1)

 

(Note 1)

 

Current Position Reading 

× 

○ 

(Note 2)

 

○ 

Number of Positions Specification 

(Note 4)

 

○ 

× 

○ 

× 

Completed Position Number Reading 

○ 

×

Signal Reading for Each Status 

○ 

Number of Max. Connectable Axes 

16 

16

16

16

Number of Selectable (Valid) Axes 

0 to 15 

0 to 15

0 to 15

0 to 15

Max. Value for Position Data 
Specification (mm or deg) 

Position Table Setting 

9999.99

(Note 3)

 

9999.99

(Note 3)

9999.99

(Note 3)

[2] RCM-GW-CC 

Main Functions 

Position Number 

Specification 

Mode 

Direct Numeric Specification Mode

Command Specification Mode

Position Data 

Limit Mode 

Normal 

Positioning Mode

Pressing 

Available Mode

Positioner 
Operation

Simplified Direct 
Value Operation

Position Data Direct 
Specification Movement 

×

 

 

 

 

(Note 1)

 

○ 

Velocity and Acceleration Direct Setup 

×

 

×

 

 

 

(Note 1)

 

(Note 1)

 

Pressing Operation 

 

×

 

×

 

 

(Note 1)

 

(Note 1)

 

Current Position Reading 

×

 

 

 

 

(Note 2)

 

○ 

Number of Positions Specification 

(Note 4)

 

 

×

 

×

 

×

 

 

×

 

Completed Position Number Reading 

 

×

 

×

 

×

 

 

 

Number of Max. Connectable Axes 

14 

14 

7

3

16

16

Number of Selectable (Valid) Axes 

0 to 13 

0 to 13 

0 to 6

0 to 2

0 to 15

0 to 15

Max. Value for Position Data 
Specification (mm or deg) 

Position Table 

Setting 

327.67 

327.67 

9999.99

(Note 3)

9999.99

(Note 3)

9999.99

(Note 3)

RCM-GW-CC Ver1.10 
Corresponding Model 

 

×

 

RCM-GW-CC Ver2 
Corresponding Model 

 

[3] RCM-GW-PR 

Main Functions 

Position Number 

Specification Mode 

Direct Numeric Specification 

Mode 

Command Specification Mode

Positioner 
Operation

Simplified Direct 
Value Operation

Position Data Direct 
Specification Movement 

×

 

 

(Note 1)

 

○ 

Velocity and Acceleration Direct Setup 

×

 

 

(Note 1)

 

(Note 1)

 

Pressing Operation 

 

 

(Note 1)

 

(Note 1)

 

Current Position Reading 

×

 

 

(Note 2)

 

○ 

Number of Positions Specification 

(Note 4)

 

 

×

 

 

×

 

Completed Position Number Reading 

 

×

 

 

 

Signal Reading for Each Status 

 

 

 

 

Number of Max. Connectable Axes 

16 

16

16

16

Number of Selectable (Valid) Axes 

0 to 15 

0 to 15

0 to 15

0 to 15

Max. Value for Position Data 
Specification (mm or deg) 

Position Table Setting 

9999.99

(Note 3)

 

9999.99

(Note 3)

9999.99

(Note 3)

Note 1  Although an operation cannot be performed with specifying values directly, it is available to operate by rewriting the 

data on the position table from the write command. 
Please note, however, that the EEPROM has a 100,000 write limitation. Consider the effect of this mode with regard to 
product lifespan. 

Note 2  Direct reading cannot be performed since it is not the constant output. However, reading is available from the read 

command. 

Note 3  This is the maximum value that can be written to the data field; however, the maximum value input should not exceed 

the actuator stroke. 

Note 4  The number of available positions varies according to which PIO pattern is selected through the Operation Mode 

parameter. 

Limitation in Number of 

Positions by PIO Pattern 

Select 

ERC2 Standard, PCON-C/CG/SE, ACON-C/CG and SCON

ERC2-SE

ACON-SE
PCON-SE

PIO Pattern (Parameter No.25) 

ERC2

Operation Type 

Standard 

Solenoid 

Valve Type 

Zone Signal 

Type

Position 

Zone Type

SIO 



SIO Type

Position Number 

Specification Mode 

×

 

16 

16 

64 

 

64 

Command 

Specification Mode 

×

 

16 

16 

64 

 

64 

PCON
ACON
SCON

Operation Type 

Positioning 

Mode 

Teaching 

Mode 

256-point 

Mode

512-point 

Mode

Electromagnetic 

Valve Mode 1 

Electromagnetic 

Valve Mode 2 

SIO Type

Position Number 

Specification Mode 

64 

64 

256 

512 

×

 

64 

Command 

Specification Mode 

64 

64 

256 

512 

×

 

64 

[Refer to the instruction manual of each controller for PIO pattern details.] 

Model

Serial number

MODEL  RCM-GW-DV 

SERIAL No. 800056144     MADE IN JAPAN 

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the DVD Manual included in the box this device was packaged in. It should be retained 

with this device at all times. 

 

A copy of the DVD Manual can be requested by contacting your nearest IAI Sales Office listed at 

the back cover of the Instruction Manual or on the First Step Guide.

 

1D

 

Summary of Contents for RCM-GW

Page 1: ...ication Communication Protocol RS485 conformance Communication System Start Stop Synchronization System Half Duplex Communication Baud Rate 230 4kbps Error Control System Non parity bit CRC 1 Communication Cable Length Total Cable Length 100m or less Communications Cable Twisted pair shielded cable Recommended Taiyo Cabletec Corporation K SB 20276 Length m 2P AWG22 Environment Surrounding air temp...

Page 2: ...Enable Always ON b contact Enable SIO Communication Line Wiring Layout There should be no problem to have a terminal block connection instead of a 4 way junction Use a terminal block connection or direct joint connection if there is a concern that a faulty connection may occur as a result of using the E Con connector 17 5 17 5 φ5 Hole 178 5 170 5 161 68 1 RCM GW DV RCM GW CC RCM GW PR Note Dimensi...

Page 3: ...and the extended cyclic settings cannot be used for other purposes Refer to Instruction Manual DVD for the details of the address assignment No Mode Remote I O Data Register GW PLC RX PLC RY GW GW PLC RWr PLC RWw GW 1 Position number specification mode 7 words 7 words 9 words 9 words 2 Direct numeric specification mode Position Data Limit Mode 7 words 7 words 16 words 16 words 3 Normal Positioning...

Page 4: ...d ON Illuminating CPU error Please contact us G ER RD OFF CPU is operating in normal condition Illuminating Either an error is occurred on CC Link module or the connection with CC Link is not established Check the communication status LEDs for the connection to CC Link and check the settings and wirings Even if this LED is ON the connection to the teaching tool is available as long as RUN is turne...

Page 5: ...ating Status is off line OFF The machine is not off line ERR RD 1Hz Flashing There is a configuration error Exnample The number of input and output set with the mode setting switch does not match with the number of input and output set with the configuration tool 4Hz Flashing It is a communication board ASIC initializing error Please contact us if the condition does not recover even with a reboot ...

Reviews: