background image

CCE900-IP-TR 

        CCE900-IP-T & CCE900-IP-R 

User’s Guide

 

i-Tech Company LLC 

TOLL FREE: (888) 483-2418 • EMAIL: 

[email protected]

  • WEB: 

www.iTechLCD.com

 

Summary of Contents for CCE900-IP-R

Page 1: ...CCE900 IP TR CCE900 IP T CCE900 IP R User sGuide i Tech Company LLC TOLL FREE 888 483 2418 EMAIL info iTechLCD com WEB www iTechLCD com ...

Page 2: ...eo contents 1 1 Features Simply attach the VGA DVI audio to the CCE900 IP T transmitter it starts to encode and streaming to the Ethernet Simply attach the CCE900 IP R receiver to the display it starts to decode from the network to the display and speaker Support one to many with no delay in between each receiver Also support multiple Transmitters to multiple Receivers if the Ethernet switch has t...

Page 3: ... 1050 1680 x 1050 1360 x 768 Output frame rate 640X480 70fps 800X600 70fps 1024X768 60fps 1280X1024 30fps 1600X1200 30fps 720X480 60fps 720X576 50fps 1280X720 30fps 1440x900 30fps 1400x1050 30fps 1680x1050 30fps 1360x768 30fps 1920X1080 25fps Scalar support Allows difference input and output resolution also support input VGA output DVI D input DVI D output VGA LAN 10 100Mbps Auto MDIX Flow control...

Page 4: ... T Mini USB to PC USB 5 Use optional accessory of IR blaster cable to connect CCE900 IP T IR Out and adjust the IR blaster LED face to the IR receiver of your Media Center PC TV tuner card or DVD player 6 Use CAT5e 6 7 cable to connect CCE900 IP T Ethernet to the Ethernet switch or directly to the CCE900 IP R All of CCE900 IP T and CCE900 IP R must be put in the same network and should not be inte...

Page 5: ...onnect CCE900 IP R to the DVI monitor 2 Use accessory of audio cable to connect CCE900 IP R Line Out to speaker and plug microphone into the Mic In port 3 If you need remote keyboard mouse function plug keyboard and mouse to the PS2 or optional USB port 4 If you need remote RS232 function plug RS232 cable to the RS232 port 5 If you need remote IR function connects optional IR receiver cable to the...

Page 6: ...5LEDsontheCCE900 IP R pleaserefer to the below table for the status of CCE900 IP R Power LED Red Green R Green J45 Orange Status Off No Power On System OK network is not connected Blink On System failed On On System OK network is connected but not able to link with Transmitter On On System OK linked with Transmitter On On On System OK dis connected with Transmitter the Power LED in orange color On...

Page 7: ... menu showing a list of all CCE900 IP T Transmitters as below picture The above menu shows 4 x CCE900 IP T are found in the network with nameofKV 9001 PC1 KV 9001 PC2 KV 9001 PC4 The2 0 1 3in the right column indicates the number of Receivers are currently connected with that Transmitter Navigate to the desired Transmitter PC with the arrow keys and press Enter The selected CCE900 IP T PC screen a...

Page 8: ...C REFRESH CCE900 IP T SETTING CCE900 IP R OFF Connection Method EXIT Press the Source button of the CCE900 IP R allows the proper CCE900 IP T to be selected after 3 seconds the CCE900 IP R will connect to that CCE900 IP T as below Connecting to After the CCE900 IP T and CCE900 IP R connection is established the CCE900 IP R will display the PC screen that is connected to that CCE900 IP T 3 3 The Ot...

Page 9: ...et CCE900 IP T as multicast mode for one to many or unicast mode for one to one 3 3 3 2BANDWIDTHSETTING This function adjusts the bandwidth usage of the CCE900 IP T There are three levels for selection LOW MID HIGH Please note to set LOW it will use lower network bandwidth and get a more efficient performance but will come with lower image quality 3 3 3 3INFORMATION This function shows theCCE900 I...

Page 10: ...e CCE900 IP T which it found first 3 3 5 2 By Priority This function sets the CCE900 IP R to connect to the CCE900 IP T according to the priority You can set the 1st priority and the 2nd priority for 2 different CCE900 IP T transmitters As the following picture there are two sections each has a list of all Transmitters that are currently on the network just press the source button to move the high...

Page 11: ...nd navigate to the REFRESH the display will show as below Searching CCE900 IP T Pleasepushthebuttonagainduringthesystemisstillsearching the CCE900 IP T The OSD menu with CCE900 IP R SETTING will be shown as below CCE900 IP T 0337 192 168 168 201 03 27 REFRESH CCE900 IP R SETTING CCE900 IP R OFF Push the source button again to navigate to the CCE900 IP R SETTING the following OSD menu will prompt 1...

Page 12: ...able the microphone input function 3 4 2 IR INPUT There are 3 options for IR input IR DISABLE Turn off the IR function INTERNAL IR To set the IR receiver from internal socket EXTERNAL IR To set the IR receiver from extension cable 3 4 3 Connection Method Please refer to 3 3 5 11 ...

Page 13: ...nal IP otherwise you will not be able to configure the CCE900 IP T In case of missing the final IP you should use a special software tool to find IP out Please follow below steps to configure the IP settings Step 1 ForCCE900 IP R assign your PC IP address in between 192 168 168 1 and 192 168 168 254 excluding 192 168 168 22 and the subnet mask with 255 255 255 0 For CCE900 IP T the factory default...

Page 14: ... Use a straight Ethernet Cable to connect the PC with the device The Status or Power LED is still lit in orange Step 7 Ping the connected device through the sequence Start Run cmd ping TX IP or ping 192 168 168 22 for RX If you receive the reply it means the device is ready for setup mode Use IE browser to open the setup page For CCE900 IP R the URL is http 192 168 168 22 For CCE900 IP T the URL i...

Page 15: ...he subnet mask with 255 255 255 0 For CCE900 IP T assign your PC IP address to the same network as CCE900 IP T For example if the CCE900 IP T IP is 10 100 1 10 you might set your PC IP address as 10 100 1 1 and the subnet mask as 255 0 0 0 Step 3 Hold the Reset button of the device Step 4 Keep holding the Reset button and plug the power on Step5 TheCCE900 IP T Status orCCE900 IP R Power LED willbl...

Page 16: ...0 IP R firmware Step 9 Navigate to the firmware file and click Upgrade Upgrade process may take a few minutes Please do not turn off PC or the device or unplug the Ethernet cable It will cause damage of the device After firmware upgrade is accomplished turn off the device Note You have to disable antivirus software and firewall software before you upgrade firmware Firmware upgrade process cannot b...

Page 17: ... his her PC You should download and install the below software before installing this Management software Net Framework 2 0 or above WinPcap 4 1 2 Downloadable at http www winpcap org install default htm To install double click SETUP EXE and follow the setup wizard After the installation is finished click LAN Manager 4 0 icon to start the Management Software 16 ...

Page 18: ...d the connected Receivers RX on the right is a two tab view one is a List view of the RX and the other is a Matrix view of TX and RX the former lists all of RX but no TX and the latter displays a matrix table in a coordinate style the horizontal axis is a list of RX and the vertical axis is of TX 17 ...

Page 19: ...hange Name and type the IP or name on the pop up window and click Submit 5 2 Reboot the device Right click the device you desire to reboot select Reboot from the menu 5 3 Information Right click the device select Information a window will pop up with information about the device The value in the version field may or may not display the version when it fails to detect the version it will display N ...

Page 20: ...epending on the performance of your PC and network bandwidth you can activate multiple windows for multiple CCE900 IP T screen sources The default frame rate for the CCE900 IP T is 30 frames per second You can change the frame rate by clicking Setting Tx Frame Rate Setting on the upper left corner of the Management Main screen Click it and a window will pop up and from here you can specify the FPS...

Page 21: ...ext menu Move the mouse over the Switch to Transmitter function and select the TX from the sub menu by clicking it In Matrix view click the intersected cell that represents a Transmitter with a Receiver The selected cell is ticked S You can select multiple cells one by one Finally click the connect button on the upper right corner to start connection The tick sign S in the checked cells will turn ...

Page 22: ... the CCE900 IP R RS232 Baud Rate Select Receiver s right click to get the context menu Then mouse over the Setting UART Baudrate item the sub menu will show up Select one from the list to set the baud rate 21 ...

Page 23: ... click it to bring up a window First specify the message format ASCII or Binary If you specify Binary the message is supposed to be like 00 01 ff be sure to separate each byte with white space Second type the message in the Request text area Third click Submit to send the message If there is response it will be displayed in the Response text area 22 ...

Page 24: ... a template you previously saved just click Load from Template to bring up a window that lists the templates you saved previously Select the template and click Select Or if you want to delete the template just click Delete 5 8 ManageConnection Method This function is for RX with version ab26 or above if the RX is as far back as under ab26 or if the version information is N A the Connection Method ...

Page 25: ...setting By Priority means the RX will connect according to the priority list Click By Priority and a similar window will pop up you could specify up to two TX Just place them in order of priority and click Submit Dedicated means the RX will connect to the specified TX Click Dedicated and a window will pop up Select one TX from the list and click Submit 24 i Tech Company LLC TOLL FREE 888 483 2418 ...