background image

PETROL GENERATOR

M

odel

HY

12000LE & HY12000LE-3

User

 

Manual

Summary of Contents for HY12000LE

Page 1: ...PETROL GENERATOR Models HY12000LE HY12000LE 3 User Manual ...

Page 2: ...ION CHECKS 7 8 4 OPERATION 8 10 5 STARTING THE ENGINE 10 11 6 STOPPING THE ENGINE 11 7 USING THE MACHINE 11 13 8 BATTERY 13 14 9 PERIODIC MAINTENANCE 14 17 10 TROUBLESHOOTING 18 19 11 STORAGE 19 12 SPECICIFATIONS 20 13 WIRING DIAGRAMS 21 22 14 CONTACT DETAILS 23 15 DECLARATIONS of CONFORMITY 24 ...

Page 3: ...re to their warning s Failure to do so may result in personal injury Warning Signs and Symbols FOLLOW safety messages to avoid or reduce risk of injury or death DANGER indicates a hazard which if not avoided could result in serious injury or death WARNING indicates a hazard which if not avoided could result in serious injury or death CAUTION indicates a hazard which if not avoided might result in ...

Page 4: ...onoxide poisoning 1 3 5 DO NOT use in an enclosed area or a moving vehicle 1 4 General fuel safety 1 4 1 Fuel Safety additional information can be obtained from the Health and Safety Executive HSE document SR16 1 4 2 All fuels are Flammable 1 4 3 Keep away from all ignition sources i e Heaters Lamps sparks from Grinding or welding 1 4 4 Hot work on tanks that have contained fuel is extremely dange...

Page 5: ...l isolation method and always isolate all electrical supplies prior to carrying out any maintenance work 1 4 10 3 Prior to use and with all electrical supplies isolated check all electrical cables plugs and connections for the following 1 4 10 3 1 Are intact and have no signs of damage to include but not limited to bare wires chaffing cuts and loose wiring If there are any signs of damage the dama...

Page 6: ... 1 1 The engine and exhaust will become very hot during use do not touch 1 5 1 2 These items remain hot for some time after use 1 5 1 3 Place the machine in an area where pedestrians or children are not likely to touch the machine 1 5 1 4 Avoid placing any flammable materials near the exhaust outlet during operation 1 5 1 5 Keep the machine at least 1 m from buildings or other equipment or the eng...

Page 7: ...T refill tank while engine is running or HOT 3 1 5 Close fuel tap before re fuelling 3 1 6 DO NOT allow any dust dirt water or any other foreign objects get into the fuel or fuel tank 3 1 7 Wipe off any spilt fuel thoroughly before starting the engine 3 1 8 Keep all sources of ignition and naked flames away from the area in which you are fuelling machine 3 2 Check Engine oil 3 2 1 Before checking ...

Page 8: ...1 Engine switch 4 1 1 RUN indicates the engine in RUN position OFF indicates the engine in OFF position START indicates the engine in starting position You must always turn engine switch to OFF position when generator is not in use 4 2 Fuel valve 4 2 1 The fuel valve is used to control the fuel flow from the tank to the carburetor After stopping the engine the fuel valve should turn to Off positio...

Page 9: ... automatically 4 4 2 It is required to prevent the generator set from short circuit or overload 4 4 3 If the circuit breaker drops out DO NOT turn on the circuit breaker without first checking for overload and or short circuits 4 5 Grounding terminal Earth connection DO NOT use generator without first connecting to ground earth connection 4 5 1 The grounding terminal Earth connection is a special ...

Page 10: ...RTING THE ENGINE Before starting the engine Turn OFF the AC switch DO NOT connect any electrical appliances to the machine 5 1 Turn the fuel tap to ON position 5 2 Turn the engine switch to RUN 5 3 Pull the choke lever to the CLOSED position Not necessary when engine is warm 5 4 Turn the start switch to START position Do not keep the switch in the START position for more than 5 seconds or the star...

Page 11: ...erature range 15 C to 40 C 7 1 2 Humidity level 95 7 1 3 Serviceable elevation 1000 m If using at heights over 1000 m the rated output power will decrease 7 2 Connection to power supply DO NOT Connect the generator to Mains AC sockets in your building commonly known as back feeding it is extremely dangerous and illegal When the generator is being used as a backup power supply in the event of a pow...

Page 12: ...our generator will shorten its service life 7 4 1 Before starting the generator you must confirm that the total power of the appliances do not exceed the rated power of the generator 7 4 2 When connecting loads to generator set it is recommended that you turn on the appliance with the maximum current first then turn on the next lowest current and so on 7 4 3 In general capacitive and inductive loa...

Page 13: ... the engine power will be degraded engine will overheat or damaged severely because of rarefied gas mix 7 5 1 In high elevation area the standard carburetor will give an over rich gas mix to the engine thus the output power degrades and the fuel consumption increases 7 5 2 If you intend to use the engine at an elevation over 1000m we recommended you have the carburetor replaced by an authorised de...

Page 14: ...r maintenance or running the generator with faults may cause damaged not covered by warranty Maintain the machine in accordance with the manual instruction 9 1 Good maintenance and service gives an assurance that the generator will run safely economically and without any failures 9 2 Maintenance chart Item Remark Pre use check Daily Initial and 1 Month or 20 Hours Every 3 Months or 50 Hours Every ...

Page 15: ...ck and loosen the draining screw and washer 9 3 2 After draining the used oil reinstall the draining screw and washer and tighten them In view of environmental protection please take a proper way to dispose the waste oil 9 3 3 Take the waste oil to the local recycling centre Never dump waste oil on the ground in ditches or drains Exhaust system Check for leaks re tighten or replace gasket as requi...

Page 16: ...element several times to remove dust deposited on it or blow out with high pressure air line from inside to outside of the 9 4 5 2 Never remove the dust with brush or the dust will enter the fibres and block the vent holes 9 4 6 Clean foam element 9 4 6 1 Clean the foam element with soapy water rinse and dry it or clean it with high fire point solvent and allow it to dry 9 4 7 Clean air cleaner br...

Page 17: ... after depressing the washer retighten it 1 8 1 4 turn 9 5 9 Reinstall the spark plug cap 9 6 Clean fuel filter 9 6 1 Close the fuel valve Detach the depositing cup and remove the O ring and screen 9 6 2 Clean the depositing cup the O ring and screen with uninflammable or high flash point solvent 9 6 3 Reinstall the O ring and the screen tighten the cup 9 6 4 Open the fuel valve to check if there ...

Page 18: ...tion chamber Insufficient pulling speed on recoil starting Pull recoil starting rope faster Debris in fuel tank Clean tank Blocked fuel line Clear blockage No Fuel Poor fuel Fill with fresh fuel Fuel valve not Open Open fuel valve Combustion chamber has fuel No or poor spark Spark plug dirty Clean spark plug Damaged spark plug Replace spark plug Faulty magneto Consult dealer Correct spark Improper...

Page 19: ...ORAGE To avoid burn or fire by contact with the heated parts of the engine never pack or store the engine until it is has cooled down Petrol is highly flammable and explosive liquid After stopping the engine drain fuel in a well ventilated area DO NOT allow naked flames or other sources of ignition to come into contact with petrol or it vapours Long term storage of your machine will require some p...

Page 20: ... Paper foam element Generator Type Synchronous generator Volt regulation Automatic voltage regulation Rated voltage V 220 230 240 220 380 230 400 240 415 Phase 1 phase 1phase 3 phase 3 phase Rated power kW 8 5 9 5 9 10 Max power kW 9 5 10 5 10 11 Rated frequency Hz 50 60 50 60 Power factor cos Φ 1 0 0 8 1 0 0 8 Generator set Fuel consumption g kW h 360 Continuous working time h 6 Noise 7m away fro...

Page 21: ...Page 21 13 WIRING DIAGRAMS 13 1 N B Subject to change without prior notice ...

Page 22: ...Page 22 ...

Page 23: ... address Genpower Limited Isaac Way Pembroke Dock Pembrokeshire SA72 4RW UK 14 2 Telephone and Fax contact numbers Office 44 0 1646 687880 Fax 44 0 1646 686198 14 3 Email contacts After sales service genpower co uk 14 4 Web site http genpower co uk ...

Page 24: ...s that these Hyundai products conform to the following CE Directives 15 1 1 2006 42 EC Machinery Directive 15 1 2 2004 108 EC EMC Directive 15 1 3 2000 14 EC Noise Emissions Directive 15 1 4 97 68 EC NRMM Emissions Directive 15 1 5 2006 95 EC Low Voltage Directive ...

Page 25: ...Page 25 ...

Page 26: ...Page 26 ...

Page 27: ...Page 27 ...

Page 28: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerequipment co uk ...

Reviews: