background image

1

Dual-Fuel Portable Generator

User Manual

Summary of Contents for HCP9000

Page 1: ...1 Dual Fuel Portable Generator User Manual...

Page 2: ...2 2011 Hyundai Power Equipment All Rights Reserved Licensed by Hyundai Corporation Korea hcp9000 0711 02...

Page 3: ...3...

Page 4: ...4...

Page 5: ...based on the latest product information available at the time of print Visit www powerbyhyundai com for manual updates and operation notices No part of this publication may be reproduced without writt...

Page 6: ...by Midland International Inc a licensed manufacturer of Hyundai Power Equipment www powerbyhyundai com TECHNICAL ASSISTANCE 1 855 706 8475 CUSTOMER SERVICE 1 877 528 3772 toll free SALES 1 503 534 368...

Page 7: ...0 OPERATION 4 1 Mounting Instructions 17 4 2 LPG Conversion 18 4 3 Battery Connection 19 4 4 Starting the Generator 20 4 5 Using the Generator 24 4 6 Using DC Output 25 4 7 Stopping the Generator 26 5...

Page 8: ...due to risk of burns Pay attention to the warning labels The engine exhaust system will become heated during operation and remain hot immediately after the engine is stopped Gasoline is a highly flam...

Page 9: ...ins to operate abnormally Then disconnect the device and investigate the problem Make sure that the electrical rating of the device does not exceed that of the generator If the power level of the devi...

Page 10: ...en coming into contact with engine oil Always stop the generator set before removing the oil filler cap Only qualified maintenance personnel with knowledge of fuels electricity and machinery hazards s...

Page 11: ...11 2 0 COMPONENTS 2 1 Identification of Components...

Page 12: ...argar dentro de un recipiente sellado Evite corto circuitos Recargar despu s del uso Debe ser desechada y reciclada de forma apropiada Nunca desmantelar o calentar a m s de 50 C Nunca incinerar Riesgo...

Page 13: ...13...

Page 14: ...ilation is inadequate 3 1 Engine Oil Check 1 Ensure the generator is on a level surface 2 Inspect engine oil Take out the oil filler cap and clean the dipstick Check the oil level by reinserting the o...

Page 15: ...sive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow open flames or sparks in the area where the generator is being refueled or where gasoline i...

Page 16: ...h soap and water or solvent Squeeze dry and then soak in clean engine oil 3 Squeeze out all excess oil and reinstall Replace the element if it is damaged Check the air filter using the maintenance sch...

Page 17: ...17 4 0 OPERATION 4 1 Mounting Instructions...

Page 18: ...sky hook and around the top half of the top frame tubes 4 Holding the frame tube clamp in place with one hand insert and twist to tighten the Wingbolts with washers attached Make sure the wingbolt is...

Page 19: ...ry Ensure the connection is secured by using the fastener at the battery terminal 2 Connect the black cable with the negative terminal of the battery Ensure the connection is secured by using the fast...

Page 20: ...nic Start Method Remote Start Method IF USING PROPANE FUEL SOURCE 1 Ensure that there is no gasoline in the engine If gasoline was used in the most recent operation start the generator with gasoline s...

Page 21: ...ff the propane fuel source and allow the engine to use up the remaining fuel After the engine stops continue to step 2 2 Rotate the fuel valve lever to ON position Vertical position 3 If the engine is...

Page 22: ...ON position to save fuel consumption while low load is applied to the generator set During warm up period keep the Idle Control OFF until the engine reaches operating temperature Doing so will decreas...

Page 23: ...enerator after three attempts contact customer support Repeated attempts could damage the ignition mechanism 3 Follow steps 6 7 from the Recoil Start Method REMOTE START METHOD 1 Follow fuel source se...

Page 24: ...ker switch to ON position and turn on the device To stop the engine in an emergency turn the engine switch OFF In order to maintain generator s performance Always connect the generator to the ground t...

Page 25: ...ed through vent holes in the battery during charging Do not allow sparks or open flames around the generator or battery during the charging process Electrolyte fluid can burn eyes and clothing Be extr...

Page 26: ...g all appliances from the GFCI receptacle The reset button should be flush with the test button If the reset button is not flush with the test button take it to your Hyundai Authorized generator servi...

Page 27: ...you have any maintenance questions 5 2 Maintenance Schedule ITEM TASK DAILY EVERY 20 HOURS EVERY 50 HOURS EVERY 100 HOURS EVERY 300 HOURS General Inspec tion Engine Lubricants Inspect Oil Level Replac...

Page 28: ...ebris and clean as necessary 4 Check the engine oil level and add oil as necessary Do not use gasoline or low flash point solvents for cleaning They are flammable and could explode under certain condi...

Page 29: ...il Drainage Used motor oil can cause skin irritations if left in long tern contact with skin Wash hands thoroughly with soap and water after handling oil Do not dispose of used oil in drains or on soi...

Page 30: ...lug 1 Disconnect and remove the spark plug using a wrench 2 Inspect the spark plug and clean any dirt from the electrodes with a wire brush If electrodes are worn or show signs of wear replace spark p...

Page 31: ...he storage area is free of excess humidity and dust 2 Drain the fuel tank and the carburetor DRAINING THE FUEL TANK 1 Turn the engine switch off 2 Remove the fuel tank cap and the debris screen under...

Page 32: ...red cable from the positive battery terminal 2 Disconnect black cable from the negative battery terminal Refer to Fig 4 3 3 Store the battery in a dry place and recharge it once a month Do not store...

Page 33: ...en choke Dirty air filter Clean air filter Rich fuel mixture Contact customer service Engine stops No fuel or LPG Refill fuel tank Not enough oil Add more oil Engine has dif ficulty idling Loose spark...

Page 34: ...nition mode Non contact transistor Starting mode Recoil Start Electric Start and Remote Start Max Output W rpm 11 000 3600 Fuel tank capacity Gal 13 2 Oil capacity 37 fl oz 10W30 Fuel Type Unleaded ga...

Page 35: ...35 8 0 WIRING DIAGRAMS...

Page 36: ...rchased in the United States or Canada from Cobalt Power Inc via an authorized channel of distribution This limited warranty applies to the first purchaser and each subsequent regis tered owner during...

Page 37: ...nder this warranty Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclu sion or limitation of incidental or consequential damages so the above exclu...

Page 38: ...arranty and is limited to Hyundai Power Equipment products when distributed by Cobalt Power Inc The accessories and replacement parts must be purchased from COBALT POWER INC in the United States or Ca...

Page 39: ...ation of this written warranty Some states do not allow limitations on how long an implied warranty lasts and or do not allow the exclu sion or limitation of incidental or consequential damages so the...