background image

Licensed by Hyundai Corporation, Korea

Summary of Contents for DHY8500SELR

Page 1: ...Licensed by Hyundai Corporation Korea ...

Page 2: ...l before using the Generator in order to familiarise yourself with this product and after reading please keep this manual for future reference Failure to follow the proper protocols listed in the manual may cause personal injury to the operator or damage to equipment www hyundaipowerproducts co uk 1 ACKNOWLEDGEMENT ...

Page 3: ...URE 14 SHUTDOWN PROCEDURE 16 USING THE GENERATOR 17 EMERGENCY SHUTDOWN 17 MAINTENANCE 18 AIR FILTER 20 BATTERY 21 STORAGE 21 TRANSPORTATION 21 TROUBLESHOOTING 22 SPECIFICATION 23 DECLARATIONS OF CONFORMITY 24 RECYCLING 24 CONTACT 25 WARRANTY 25 2 CONTENTS ...

Page 4: ... of the following warning signs symbols and or PPE pictograms may appear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around you DANGER Indicates a hazard which if not avoided could result in serious injury or death WARNING Indicates a hazard which if not avoided could result in serious injury CAUTION Indicates a hazard...

Page 5: ...noxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following home garage tent camper van mobile home caravan or boat This list is not exhaustive and if you are in any doubt contact your dealer 3 12 If you think you have or someone around you has been affected by carbon monoxide poisoning 3 13 Get them fresh air immediately by leaving the affected area or by opening doors...

Page 6: ...SAE10w 30 15w 40 engine oil before use or serious damage will occur 3 23 Never refuel or store the machine in a place where there is open flame spark or other forms of open flames or ignition 3 24 DO NOT attempt to start the engine if fuel is spilled Wipe away the spillage and ensure all fuel has dried before starting the machine 3 25 ALWAYS make sure the fuel cap is securely tightened and replace...

Page 7: ...an kill NEVER work on LIVE ENERGISED equipment 3 40 Prior to carrying out any maintenance work you MUST Identify electrical isolation methods and isolate all electrical supplies 3 41 Prior to use and with all electrical supplies isolated You MUST check all electrical cables plugs and connections for the following 3 42 Are intact and have no signs of damage to include but not limited to bare wires ...

Page 8: ...3 56 There is an explosion risk if the battery terminals are short circuited when connecting 0dis connecting ALWAYS exercise great care so that the terminals or battery leads are NOT allowed to touch and cause a spark ALWAYS use suitable insulated tools 3 57 VIBRATIONS where applicable 3 58 Prolonged use of hand held operated machines will cause the user to feel the effects of from vibrations Thes...

Page 9: ...ine Please read the manual carefully before attempting to use the machine 3 73 If after reading the user manual you are still unsure about the safety risks associated with use of the machine you should not use the machine Please contact your dealer for more information 3 74 These safety instructions only address the basics for safe use It would be impossible in the safety instructions to describe ...

Page 10: ... machine to stop others using it in your absence 3 90 You MUST make sure that there is always another person in the safe vicinity of your work area so that help is available should an emergency arise 3 91 The machine is tested and approved only with the equipment originally provided or recommended by the manufacturer 3 92 The engine can become very hot To avoid being burned you must turn off the e...

Page 11: ...he generator should ONLY be repaired by a skilled dealer service point 3 102 When in operation the generator noise will exceed 90 dB A Therefore all users and onlookers must wearear protection 3 103 Keep the operation area clean and free from foreign objects 3 104 DO NOT operate the generator in the presence of flammable liquids gas or dust 3 105 Keep Children bystanders and pets away whilst opera...

Page 12: ...urely closed after refueling 4 7 Take care not to spill fuel when refueling If any fuel is spilled make sure the area is clean and dry before starting the engine ADDING OIL DIESEL TO THE ENGINE 5 1 This generator is shipped with oil however DO NOT start the machine until the correct oil level has been determined 5 2 DO NOT change or add engine oil just after the engine has been running the oil wil...

Page 13: ...ted wear of the cylinder liner main bearing and failure of other moving components increase significantly The generator lifespan will be greatly reduced if oil level is not checked daily and oil is not changed every 100 hours 5 5 DO NOT add fuel or remove fuel just after the engine has been running you MUST allow the engine to cool fully before carrying out this task 5 6 Only use standard specific...

Page 14: ...EVER use a machine with a defective exhaust muffler 6 1 The machine is shipped without fuel therefore you MUST fill the engine with fuel and check that the engine has correct level of oil before starting the engine Failure to do so will result in engine damage which will not be covered by manufacturer s warranty STARTING THE ENGINE 6 2 To start the generator turn the key switch clockwise to the ON...

Page 15: ... load at a time 6 4 Connect larger loads first N B motors will draw large currents on initial start up and allow them to settle down before applying successive loads 6 5 You can display each parameter by successive presses of the mode button The total hours run will only display when engine is running 6 6 Electrical appliances particularly motor driven equipment will have a very high startup curre...

Page 16: ... 7 If the generator exceeds its load capacity the circuit breaker will trip To reset the breaker turn off and disconnect all loads Wait a few minutes then reset the breaker and add loads to up to the rated output 7 1 Except in an emergency DO NOT stop the engine suddenly or whilst under load this can damage the Automatic Voltage Regulator AVR A Turn OFF Unplug All Loads B Turn OFF all circuit brea...

Page 17: ...uld be earthed to prevent shocks Turn off the main breaker switch and remove all loads 8 10 Before starting the engine be sure to switch OFF any appliances connected to it 8 11 Ensure that the breaker switch is OFF before switching between 115v 230v 8 12 The first 20 hours are the break in period of the engine for this reason it is important to follow the following instructions during this period ...

Page 18: ...ar work gloves and long trousers CAUTION NEVER use a pressure washer to clean your generator Water can penetrate areas of the unit and cause damage to electrics and engine The use of pressure washers will result in shortened life and reduce serviceability Shut down the engine wait for all moving parts to come to a complete stop and then wait for 5 minutes before performing maintenance on the machi...

Page 19: ...engine oil O Check for fuel leakage O Check for oil leakage O Change engine oil O First time O Second and thereafter Clean oil filter O Clean O Replace Air cleaner element replacement More frequent in dusty conditions O Replace Clean fuel filter O Clean replace as required Replace Check fuel injection pump Check fuel injection nozzle Check fuel pipe Replace as required Adjust valve clearance for i...

Page 20: ...loss of engine power check the air filter You MUST make sure that the housing is free of dust and debris DO NOT allow any dust or debris to enter the engine 11 2 Remove the air filter cover by unscrewing the air filter cover wingnut in ananti clockwise direction carefully remove the cover 11 3 The fuel filter has to be changed regularly to maximize the engine output To change the fuel filter you w...

Page 21: ...ce other than 13 4 Ensure battery terminals are A Kept Clean B Kept Tight C Covered to prevent short circuiting 13 5 If the battery voltage is too low it will require charging before use 13 6 Keep the battery in a cool dry place It is important to clean the battery every three months and charge every six months 14 1 Perform all the general maintenance that the maintenance section of your User Manu...

Page 22: ... 16 2 POSSIBE CAUSES 1 Fuel valve is in CLOSED position if applicable 2 Fuel tank empty 3 Machine stored incorrectly with regards to emptying fuel system 4 Water or ice in fuel system POSSIBLE CORRECTIVE ACTIONS 1 Move fuel valve to OPEN position if applicable 2 Check and fill with fuel 3 4 Check and clean fuel tank of sludge fuel lines carburetor Refill with fresh fuel 5 Contact your dealer LA188...

Page 23: ...4cc Frequency Hz 50Hz Engine Speed rpm 3000rpm Continuous Output Power Kw 5 5kW Maximum Power Kw 6 0kW Voltage AC V 230V Sockets 1x16A socket 1x32A socket Fuel Tank Capacity L 25L DC Outputs V A 12V Battery V Ah 36AH Dimensions L x W x H mm 960 x 560 x 730 mm Net Weight kg 160kg 17 SPECIFICATION ...

Page 24: ...te which should not be disposed of in your domestic waste 19 5 You MUST recycle WEEE in accordance with your local authority or recycling centre 19 6 Battery recycling certain products contain batteries which should not be disposed of in your domestic waste 19 7 You MUST recycle batteries in accordance with your local authority or recycling centre 19 8 Unwanted packaging materials should be sorted...

Page 25: ...ake any modifications without prior notice whenever necessary 22 1 Warranty cover does not include damage caused by normal wear and tear accidents misuse lack of maintenance neglect natural disaster or other external causes to damage caused by operating the equipment in a manner outside that described in the instructions The warranty is considered void if the item has been modified altered or tamp...

Page 26: ...26 Date Hours Maintenance Undertaken Name SERVICE RECORD SHEET ...

Page 27: ...27 NOTES ...

Page 28: ...28 ...

Reviews: