background image

1

-EN

-

LOW POWER GENERATING SET

HG4000-A

WARNING: Read thoroughly the instruction manual before use

All manuals and user guides at all-guides.com

Summary of Contents for 20210500001

Page 1: ...1 EN LOW POWER GENERATING SET HG4000 A WARNING Read thoroughly the instruction manual before use All manuals and user guides at all guides com...

Page 2: ...tion If available 6 High Altitude Operation 6 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 7 STARTING STOPPING THE ENGINE 8 MAINTENANCE 1 Maintenance Schedule 2 Tool Kit 3 Engine Oil Change...

Page 3: ...ce when people especially children or pets are nearby Direct them away from the working area The operator or the user are responsible for possible accidents or damage to other persons or to their prop...

Page 4: ...d watch out for sudden changes in the rotation of the motor Risk of wounding Never cover the generator when it is running The cut out mounted on the generator has the aime of reducing the risk of elec...

Page 5: ...ssible The adjustment of this machine must not be modified or altered by the operator In case of adjustment it shall be provided by a qualified professional Security measures when filling the fuel tan...

Page 6: ...current and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in confor...

Page 7: ...dle the remaining fuel correctly and meet local environmental requirements To dispose of residual fluids proceed as follows Close the fuel tap Drain fuel from the fuel tank Empty carburetor fuel Symbo...

Page 8: ...8 Warnings on product Read them carefully before use the tool All manuals and user guides at all guides com...

Page 9: ...ION NOTE Diagrams may vary according to the types Set nameplate MOTOR SWITCH CIRCUIT BREAKER LEVIER THE STARTER FUEL VALVE AIR FILTER STARTER REEL HANDLE OIL FILTER CAP AC OUTLETS All manuals and user...

Page 10: ...e tool upside down In the food pad 2 pieces put a washer and a screw on each foot pad Localise the two holes on the bar Screw each foot bar in each hole 3 Handles Put the tool in the normal position O...

Page 11: ...fails to start release the switch and wait 10 seconds before operating the starter again 2 Recoil Starter To start the engine pull the starter grip lightly until resistance is felt then pull briskly N...

Page 12: ...enerator ground terminal is connected to the panel of the generator the metal non current carrying parts of the generator and the ground terminals of each receptacle Before using the ground terminal c...

Page 13: ...a length of heavy wire between the ground terminal and the ground source The generators have a system ground that connects generator frame components to the ground terminals in the AC output receptac...

Page 14: ...the electrical load on the circuit wait a few minutes and then reset the circuit breaker 5 High Altitude Operation At high altitude the standard carburetor air fuel mixture will be excessively rich Pe...

Page 15: ...viscosities shown in the chart may be used when the average temperature in your area is within the indicated range 1 Remove the oil filler cap and wipe the dipstick clean 2 Check the oil level by inse...

Page 16: ...This is no cause for concern If spark knock or pinging occurs at a steady engine speed under normal load change brands of gasoline If spark knock or pinging persists see an authorized generator dealer...

Page 17: ...t to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under warranty 6 STARTING STOPPING THE ENGINE Starting the engine 1 Make sure that the AC circuit breaker is in...

Page 18: ...lution WARNING Exhaust gas contains poisonous carbon modoxide Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated Periodic maintenance...

Page 19: ...your generator under severe conditions such as sustained high load or high temperature operation or use it in unusually wet or dusty conditions consult your servicing dealer for recommendations applic...

Page 20: ...vent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas WARNING Using gasoline or flammable solvent to clean the fil...

Page 21: ...g base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if...

Page 22: ...e care not to drop or strike the generator when transporting Do not place heavy objects on the generator Before storing the unit for an extended period Be sure the storage area is free of excessive hu...

Page 23: ...l into the cylinder Crank the engine several revolutions to distribute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming...

Page 24: ...the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engi...

Page 25: ...ck the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Take the electrical applia...

Page 26: ...26 11 CIRCUIT DIAGRAM All manuals and user guides at all guides com...

Page 27: ...Oil capacity L 1 1 L Sound pressure level LpA 74 6 dB A K 1 95 dB A Measured sound power level LwA 94 6 dB A K 1 95 dB A Guaranteed sound power level 97 dB A Generator SET Generator set AC output Vol...

Page 28: ...ve EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 2018 989 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the foll...

Page 29: ...policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information contained therein but a m...

Page 30: ...achine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is completed on the SWAP Europ...

Page 31: ...ore generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair station The use of a produ...

Page 32: ...29 All manuals and user guides at all guides com...

Reviews: