manualshive.com logo in svg
background image

Quick Start - Supplement

Revision C

UL 325 Standard For Safety 

Protection Against Entrapment

HySecurity Gate Operators

UL 325 – 2016

This document supplies 

site planning scenarios and reference tables

 that help explain the UL 325-2016 requirements for 

monitoring of external entrapment protection sensors. HySecurity is monitoring Normally Closed (NC) sensors to conform to 
UL 325 monitored entrapment protection requirements. 

!PPROVEDŸSENSORSŸRECOMMENDEDŸFORŸUSEŸWITHŸ(Y3ECURITYŸGATEŸOPERATORSŸAREŸSPECIÚEDŸINŸTHISŸDOCUMENTŸ

For more information regarding UL 325-2016, refer to the HySecurity website section: 

www.hysecurity.com/gatesafety

Draw-in Zones

Edge sensors protect areas of 

entrapment along posts or walls

Secure side

ublic side

Pu

Zones requiring Entrapment Protection

1. Draw-in zones 
2. Leading end
3. Trailing end

1

Trailing End

3

Leading End

2

Содержание UL 325-2016

Страница 1: ...ing Normally Closed NC sensors to conform to UL 325 monitored entrapment protection requirements PPROVED SENSORS RECOMMENDED FOR USE WITH Y3ECURITY GATE OPERATORS ARE SPECI ED IN THIS DOCUMENT For mor...

Страница 2: ...THE CURRENT 5 3TANDARD FOR 3AFETY 3EE ENERAL NTRAPMENT 0ROTECTION 0ROVISIONS PER 5 4ABLE ON PAGE NOTICE Extensive safety information exists in the gate operator product manuals Be aware and read all...

Страница 3: ...3URYLVLRQV SHU 8 7DEOH 12 8VDJH ODVV HVLJQDWHG DWH 2SHUDWRU 3URYLVLRQV 12 LDJUDP 7 SLFDO 6OLGH DWH 6LWH VVHVVPHQW 13 LDJUDP 6OLGH ULYHU QSXWV 3URJUDPPLQJ 14 LDJUDP 6ZLQJ DWH 6LWH VVHVVPHQW 15 LDJUDP 6...

Страница 4: ...6 set at the factory UL 325 Entrapment Protection Device Monitoring Required Normally Closed NC sensors tested approved Three SENSOR Inputs on Controller NSTALLER ENU CON GURABLE Build Year BY factory...

Страница 5: ...FOR SQUARE POST 10K Resistor Miller Edge Type B2 Gate Edge Module GEM 104 Edge Interface Module Normally Closed MX4037 MX3983 KIT Wired Gate Edge Sensor MGO 2E 05 T2 Square and Channel mount Edge 3 s...

Страница 6: ...3 VEHICLE DETECTOR VEHICLE DETECTOR VEHICLE DETECTOR STOP BUZZER FREE EXIT INSIDE OBSTR OUTSIDE OBSTR SHADOW RESET WIEGAND HySecurity COM NO MX000585 VERSION S N RS232 DISPLAY VEHICLE DETECTOR COM COM...

Страница 7: ...ontroller Location of Sensor Inputs on Controller Installer Menu Item Codes Smart Touch Controller STC Hydraulic gate operators Smart Touch Display Input Current Silk Screen Label 2016 Silk Screen Lab...

Страница 8: ...ept to a minimum and then install your HySecurity gate operator 2 Install NC sensors Install contact and non contact sensors edge sensors and photo eyes for all entrapment zones HySecurity gates monit...

Страница 9: ...rammed to a non zero setting before the gate will move NOTE The gate operator will not automatically cycle unless an indication is received that the appropriate number of external entrapment protectio...

Страница 10: ...direction for a 2 second interval and then resumes moving in the open direction if the photo eye clears within 5 seconds Sensor 1 2 or 3 Sensor COM COM 24V GR 0 FULL OPEN GATE EDGE LOGIC 0 Edge rever...

Страница 11: ...e use of additional safety designs components It is up to the gate system designer and installer to assess appropriate safety design and components above and beyond minimum 5 AND 34 STANDARDS LWAYS CH...

Страница 12: ...es 406 mm and does not have a pinch point between moving parts by virtue of the operator s design or as a result of INSTALLATION IN ACCORDANCE WITH INSTRUCTIONS SUPPLIED WITH THE OPERATOR AS SPECI ED...

Страница 13: ...photo eye Normally Closed EMX Industries Type B1 MX3990 IRB MON Dist 100 ft Thru beam photo eye Normally Closed EMX Industries Type B1 NOTE At minimum external entrapment protection sensors must be i...

Страница 14: ...ED TO A NON ZERO NUMBER NOTE The software requires CON RMATION OF ALL MONITORED 3 3 2 inputs before allowing the gate to move An example of the connections for an Edge and a Photo Eye monitored sensor...

Страница 15: ...Operators P N 2016 Monitored Sensors Sensor Type Output Manufacturer UL 325 Recognized MX3981 MX3983 Wired Gate Edge Sensor MGR20 2U 05 T2 Round Wraparound edge FT FOR ROUND POST 10K Resistor Miller E...

Страница 16: ...nputs must be CON GURED An example of the connections for an Edge and a Photo Eye monitored sensors and the Installer Menu settings for the Smart Touch Controller STC are shown in Diagram 4 The wiring...

Страница 17: ...t entrapment HySecurity barrier arms provide features for object detection For more information refer to the gate operator s product manual MX3186 01 02 03 Photo eye receiver not SHOWN IN ILLUSTRATION...

Страница 18: ...E CHARGER AC LOSS LOCK INTERLOCK EMERG CLOSE FIRE DEPT OPEN 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 Smart Touch Controller LIMIT DUAL GATE RADIO OPTIONS DRIVE POWER RS485 MOTOR USER...

Страница 19: ...ar in the following chart For a full list see page 5 EXAMPLE External Entrapment Protection Sensors Normally Close Contact Compatible with HySecurity Gate Operators P N 2016 Monitored Sensors Sensor T...

Страница 20: ...LOSE 1 OPEN PARTIAL INTERLOCK OPEN TIME CLOCK OPEN FREE EXIT DETECTOR DISABLE EXIT DETECTOR DISABLE CLOSE TIMER INSIDE OBSTRUCTION VEHICLE DETECTOR OUTSIDE OBSTRUCTION VEHICLE DETECTOR SHADOW RESET VE...

Страница 21: ...RAW IN ZONE 4 NY GAP LARGER THAN o MM between gate and fixed objects must be protected Install wrap around edge sensors where gap between post and gate creates a DRAW IN ZONE After wiring your extern...

Страница 22: ...Photo eye Secure Side Photo eye TRANSMITTER OUNT ACCESS CONTROL DEVICES AT LEAST FT M BEYOND THE GATE Reflector for Photo Eye After wiring your external entrapment protection sensors to the Controlle...

Страница 23: ...OOTING The Smart Touch Controller reports system malfunctions using three simultaneously occurring methods Codes presented on its display alert fault or error CTIVATION OF A BUZZER WHICH EMITS A SERIE...

Страница 24: ...gn photo eye Replace photo eye battery if needed ALERT ACTION BLOCKED GATE EDGE Open or Close 2 5 chirps indicating that the command cannot be initiated Operator received command to run open but movem...

Страница 25: ...OST 10K Resistor Miller Edge Type B2 Gate Edge Module GEM 104 Edge Interface Module Normally Closed MX3982 MX3983 Wired Gate Edge Sensor MGS20 2U 05 T2 Square Wraparound edge FT FOR SQUARE POST 10K Re...

Страница 26: ...5 VERSION S N RS232 DISPLAY VEHICLE DETECTOR COM COM A B RPM COM OPEN S 1 24V 24V STATUS LED WIRED EDGE SENSOR WITH GEM GATE EDGE MODULE 1 Turn OFF power 2 Connect the Green NC relay wire from GEM to...

Страница 27: ...E FIRE DEPT OPEN 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 Smart Touch Controller LIMIT DUAL GATE RADIO OPTIONS DRIVE POWER RS485 MOTOR USER 1 USER 2 USER 3 VEHICLE DETECTOR VEHICLE DE...

Страница 28: ...ZER FREE EXIT INSIDE OBSTR OUTSIDE OBSTR SHADOW RESET WIEGAND HySecurity COM NO MX000585 VERSION S N RS232 DISPLAY VEHICLE DETECTOR COM COM A B RPM COM OPEN S 1 24V 24V STATUS LED PHOTO EYE TRANSMITTE...

Страница 29: ...4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 Smart Touch Controller LIMIT DUAL GATE RADIO OPTIONS DRIVE POWER RS485 MOTOR USER 1 USER 2 USER 3 VEHICLE DETECTOR VEHICLE DETECTOR VEHICLE DETECT...

Страница 30: ...CLE DETECTOR SHADOW RESET VEHICLE DETECTOR SENSOR 1 SENSOR COM DO NOT USE SENSOR 2 DO NOT USE SENSOR 3 DO NOT USE CHARGER AC LOSS LOCK INTERLOCK EMERG CLOSE FIRE DEPT OPEN 2 3 4 5 6 7 8 9 10 11 12 14...

Страница 31: ...RUCTION VEHICLE DETECTOR SHADOW RESET VEHICLE DETECTOR SENSOR 1 SENSOR COM DO NOT USE SENSOR 2 DO NOT USE SENSOR 3 DO NOT USE CHARGER AC LOSS LOCK INTERLOCK EMERG CLOSE FIRE DEPT OPEN 2 3 4 5 6 7 8 9...

Страница 32: ...DO NOT USE SENSOR 3 DO NOT USE CHARGER AC LOSS LOCK INTERLOCK EMERG CLOSE FIRE DEPT OPEN 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 Smart Touch Controller LIMIT DUAL GATE RADIO OPTIONS...

Страница 33: ...Page intentionally left blank...

Страница 34: ...Page intentionally left blank...

Страница 35: ...TION MADE TO PRODUCTS WILL VOID THE WARRANTY UNLESS THE MODI CATIONS ARE APPROVED IN WRITING BY Y3ECURITY in advance of the change this exclusion does not apply to normal installation of approved acce...

Страница 36: ...Gate Inc Federal copyright law prohibits the reproduction distribution or public display of copyrighted materials without the express written permission of the copyright owner unless fair use or other...

Отзывы: