background image

INSTRUCTIONS

WATER CHILLERS

Active Aqua Chiller, 1/10 HP

Active Aqua Chiller, 1/4 HP

DISTRIBUTED BY

www.hydrotek.ca

®

Summary of Contents for Active Aqua Chiller, 1/10 HP

Page 1: ...INSTRUCTIONS WATER CHILLERS Active Aqua Chiller 1 10 HP Active Aqua Chiller 1 4 HP DISTRIBUTED BY www hydrotek ca...

Page 2: ...perature sensor Filter front cover Front cover Condenser Compressor Circuit board Control box Back cover of circuit board Top cover Water inlet outlet adaptor PERFORMANCE CURVE THE REFRIGERATION PERFO...

Page 3: ...ter Refrigerated 50L 52 F 1 F Water Temperature After Refrigeration Water Refrigerated 100L 61 F 1 F Water Temperature After Refrigeration Water Refrigerated 150L 66 F 1 F Refrigerant R134a Refrigeran...

Page 4: ...it board Seal sleeve Nut Condenser Handle Compressor Base Tank with evaporator Fan Back cover Filter front cover Front cover Control panel Front trim cover Circuit board Top cover PERFORMANCE CURVE TH...

Page 5: ...ed 150L 60 F Refrigerant R134a Refrigerant Weight 210 240g Rate of Flow 1000 2500L h 264 660gal h Weight 41 lbs Size 17 6 x 13 x 17 3 1 2 and the aquarium capacity is 52 GAL to 132 GAL When reservoir...

Page 6: ...gh quality condenser is manufactured by American OAK production line Anti corrosive pure titanium evaporator for fresh and salt water The compressor protection device system is built to shut off the c...

Page 7: ...INSTRUCTIONS www hydrotek ca INTRODUCTION SUGGESTIONS FOR SAFE OPERATION TERMS AND SYMBOLS WHERE TO INSTALL...

Page 8: ...INSTRUCTIONS www hydrotek ca ASSEMBLY INSTRUCTIONS...

Page 9: ...INSTRUCTIONS www hydrotek ca OPERATION WARNINGS SETTING THE TEMPERATURE TEMPERATURE DISPLAY TEMPERATURE ERROR ADJUSTMENT...

Page 10: ...INSTRUCTIONS www hydrotek ca COMPRESSOR OPERATION ERROR CODE CLEANING AND MAINTENANCE...

Page 11: ...n Turn on the power Plugged in incorrectly Be sure the power cord is fully plugged in The unit cycles on and off Wrong voltage and or frequency Apply to correct power source Chiller is in protection m...

Page 12: ...www hydrotek ca WARRANTY LIMITED WARRANTY GARANTIE LIMIT E GARANT A LIMITADA...

Page 13: ...r replacement collars extras x 2 ea d Replacement fuse x 1 ea Assembly Instructions Remove the chiller unit and all of the contained hardware from the box and packing material Set the chiller unit upr...

Page 14: ...ted on the back of the unit Remove the notched fuse slide from the compartment by pulling it straight out A small screwdriver or pointed tool may be needed to remove the slide Check the fuse and inter...

Page 15: ...cessible Clean both with a vacuum and or brush 8 Replace the air inlet filter and grill to the front Special Notes and Instructions The cooling e ciency of this unit is rela ve to the surrounding envi...

Page 16: ...tains the spare fuse STEP 2 Insert flat head screwdriver and pull forward to remove fuse cover STEP 4 STEP 7 STEP 8 STEP 3 STEP 5 Remove the Fuse in Use as abo shown ve STEP 6 Insert the Fuse in Use i...

Reviews: