background image

L-

300

 

Bed

 Quick Start Manual

Bluetooth Models

Class I, Type B, IPXO, Equipment 

Revised  March 

23

, 2018

Summary of Contents for L-300 Bed

Page 1: ...L 300 Bed Quick Start Manual Bluetooth Models Class I Type B IPXO Equipment Revised March 23 2018 ...

Page 2: ...ing registered as a Class I medical device with the FDA Each component must first pass a rigorous 5 000 hour life expectancy test before being used inproduction During production each product must pass a 268 inspection checklist receive approval from four different employees and managers and undergo a 24 hour testing process before being considered ready for shipment All products come with a two y...

Page 3: ...om Preparations 8 Delivery Unpacking Instructions 9 Delivery Moving Bed to Desired Location 11 Touchscreen Installation 14 HydroMassage Initial Start up 17 Bluetooth Setup 18 Final Assembly 22 HydroMassage Post Installation Training 23 HydroMassage Touchscreen Overview 24 External Temperature ControlUnit Installation 29 HydroMassage Maintenance Schedule 32 HydroMassage Installation Checklist 34 LL...

Page 4: ...ectrical device IV the product has been damaged by an act of God accident misuse abuse negligence or any other use other than the product s intended use as set forth in the company s specifications V the product has suffered damage from mishandling of the product Vl external trauma or Vll distilled water was not used The warranty does not cover cosmetic damage The sole remedy under this warranty i...

Page 5: ...and or replacement as set forth above except where prohibited by law JTL shall not be responsible for any damages whether direct indirect consequential incidental or economic in this limited warranty Some states may not allow the exclusion or limitation of consequential or incidental damages so the above limitation or exclusion may not apply to you This thereby limits the duration of all implied w...

Page 6: ...the treatment session position the user in the middle of the bed with legs together and the feet resting at the pump foot end The head should be resting comfortably on the cervical support pillow with the curve under the neck The pillow should be removed if treatment will include the cervical neck and shoulder area After treatment it is recommended that the user remain lying down for 45 seconds or...

Page 7: ...t Always lift your equipment by the metal frame Never lift your equipment by the plastic tank as it may cause cracking Do not store transport or operate your equipment in freezing conditions without completely draining the tank pump radiator or chiller It is recommended that air be blown through each of these critical parts to ensure that they are totally free of water In order to maintain tempera...

Page 8: ...l Cooler Unit External Cooler Dimensions N A N A 17 W x 21 L x 14 H 41cm wide x 61 cm long x 36 cm high External Cooler Weight N A N A 70 lbs 32 kg Maximum User Weight 400 lbs 180 kg 400 lbs 180 kg 400 lbs 180 kg Massage Area 200 100 66 L x 12 W 167 cm long x 30 cm wide 66 L x 12 W 167 cm long x 30 cm wide 66 L x 12 W 167 cm long x 30 cm wide Massage type Full Body Effleurage Full Body Deep Tissue...

Page 9: ... within 5 of the center of the HydroMassage bed CAT 5 or Cat 6 Internet Network connection at least 6 from bed Please be sure your electrical installation is completed before the unit arrives If the equipment will be installed in a patient care area additional electrical requirements may apply Water Requirements Distilled water contains no chlorine and is free of minerals and other chemicals that ...

Page 10: ...1 Using Tip Snip snip packing bands Step 2 Remove Lid Step 3 Remove box sleeve by lifting up Step 5 Using small scissors remove plastic shrink wrap around the bed IMPORTANT Do not use knife or razor Step 4 Pull down box at base and sides Step 6 Unsnap and remove cover sheet and comfort pad L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 9 of ...

Page 11: ...f six blue packing bolts three on each side of bed as shown in figure 3 used to secure bed to plywood shipping platform NOTE In addition remove the Touchscreen Computer as shown in the embedded image above AND remove the Pole Computer and Supply Boxes as shown below IMPORTANT Do not carry unit or move by using plywood shipping platform Figure 3 L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterp...

Page 12: ...nclude External Cooling Systems Refer to customer invoice if needed Continued Follow the steps below when unpacking HydroMassage Bed Shipping Crates Step 9 Slide bed off the shipping skid IMPORTANT Ensure to carefully place on the ground Figure 4 L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 11 of 36 ...

Page 13: ... the floor walls and door threshold and to assist in sliding the bed if necessary IMPORTANT If included move External Cooling System near pump foot end of bed as shown below Step 3 Place side and end panels back on unit as shown below in figure 1 and 2 Snap both cover sheet and comfort pad to bed as shown below in figure 3 NOTE Use black screws from Parts Supply Box to secure end panels Figure 1 P...

Page 14: ...l Cooling System If Applicable Wired Touchscreen with Mounting Arm NOTE Ensure to include a T Max controller if applicable Any additional items as specified on the invoice THIS IS THE END OF THE DELIVERY AND UNPACKING INSTRUCTIONS External Cooling Systems Package L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 13 of 36 ...

Page 15: ...n Arm with wiring back view Touch Screen Arm Support Receiver located on top side of bed frame Allen Wrench to tighten touchscreen arm if necessary Found in bag attached to frame Power cord wiring to touchscreen can be routed to either side L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 14 of 36 ...

Page 16: ... frame Touchscreen may be mounted on either side on the bed frame 4 Run pole power cord through Touchscreen Arm You willneed to feed the touchscreen power cord thorugh the bottom of the arm The power will be attached to frame in bas as shown below it can be routed to either side across frame support depending on whih side touchscreen arm is being installed L 300 Bed Quick Start Manual V2 0 2018031...

Page 17: ...over 6 Secure cables to arm using wire tie Extend touchscreen swivel forward for full range of motion before securing wire tie to ensure proper positioning of cables 7 Users may plug headphones into headphone jack on back of touchscreen 8 If installing T Max or other remote usage controls make connection at this point NOTE Call HydroMassage technical support at 727 536 5566 with question Secure ca...

Page 18: ...n 3 Unscrew small PVC breather tube andscrew the large PVC Water Filler Tube found in Parts Supply Box at the foot end of the tank to add water 4 Add first 5 gal 19 liters of water ONLY of the total 30 gal 114 liters to be added 5 Plug the 22V power cord into the 220V wall outlet IMPORTANT The touchscreen will power up as the 220V power cord is plugged in The touchscreen is now hard wired into the...

Page 19: ...droMassage Touchscreen must be paired to Bluetooth Module 1 Hold the HydroMassage Logo in the top left corner and type in 120700 and hit enter Select the button for Advanced Options on the bottom of theapp 2 Select the Bluetooth Manager button on the left side of screen as shown below 3 The Bluetooth Manager Window will display like the picture below ...

Page 20: ...n top of the control box at the rear of the lounge Match the Bluetooth ID on the control box sticker with the serial number on the screen and click Pair 5 After selecting the Pair button a Bluetooth paring request window will display shortly after picture below Do not hit any buttons or do anything on this window as the Bluetooth chip will automatically connect itself to the tablet and this window...

Page 21: ...d Error indicator will appear 6 After the initialization window disappears from the touchscreen add the remaining 25 gal 95 liter of water Once all water is added remove the fill tube and reinstall the breather tube 7 Press green START button on touchscreen to turn on HydroMassage for the first time Check under unit for any visible signs of leaks 8 If Water Temp Cold warning message is displayed o...

Page 22: ...ing properly Entertainment Massage Pressure Massage Area Limits Massage Travel Speed Temperature 1 Test touchscreen controls Confirm the HydroMassage is working properly by testing the pressure bars change the massage speed and launch the entertainment options at least 1X each 2 Test the cooling system either external and internal For 440 450 Models Admin screen to view temperature settings Start ...

Page 23: ...oring 2 Re attach end panels first and side panels second 3 Fasten panels securely with end panel knobs screws 4 Re attach comfort pad first and top cover sheet second When attaching the comfort pad begin with the snap at the head end and work your way around the bed until entire pad is attached to the panesl The nylon cover sheet will attach to the comfort pad with snap connections There is an op...

Page 24: ...d but do not machine dry Defoamacide and water filler tube are attached to the frame at the foot end of the lounge Customer should understand how to remove the side and end panels and be able to identify the key components pump electrical box breakers pressure valve drive motor cooling system rubber barrier and drain 5 Troubleshooting If the pressure unexpectedly rises and falls during the massage...

Page 25: ...ette and slide massage limits down on 1 60 scale to set high limit Pressure Adjusts the intensity of the massage on a scale from 1 10 2 38 PSI Speed Controls how quickly the jets travel along the body 4 speeds Time Indicates the time remaining of the massage May only be adjusted prior to pressing Start Entertainment Users may listen to music play games watch movies etc Log On Allows users to enter...

Page 26: ... blue To adjust the Speed either press the Speed Up or Down arrows or press one of the four bars directly c Limits The High and Low Limits allow the user to set their desired massage zone by indicating two points along the body which the massage will stay between The High Limit is the point that the massage will not travel above on the body and conversely the Low Limit is the point that the massag...

Page 27: ...ld always be selected unless an external timer is to be used When hooking up an external timer the following two options may be selected For either option make sure the contact closure is continuity only See External Timer Connection Section for more details 1 Pulse The lounge will run for the number of pulses it receives from the timer usually a dollar bill reader multiplied by the Pulse Value mi...

Page 28: ... 727 536 5566 www HydroMassage com Page 27 of 36 Changing the LED Colors Open Advanced Options Click on the LED Color box to open the LED Color Picker Select desired color and close Default Blue is Red 0 Green 66 Blue 225 Use the slide bar to adjust then click close ...

Page 29: ...L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 28 of 36 HydroMassage External Timer Connection Diagram ...

Page 30: ...ne electrical cord and two small water lines Water lines enter thecooling unitfromthesideandneed5 ofclearance External temperature control unit must bemounted level Any tilt greater than 2 should be remedied during installation INSTALLATION ABOVE A HYDROMASSAGE ROOM For liability reasons HydroMassage technicians are not permitted to install the temperature control unit above a customer s room Ensu...

Page 31: ...oMassage through the wall if possible Two conduits separate conduit for water and power lines are required within the wall adjacent to the HydroMassage unit feeding a single gang box with a faceplate near the foot end of the HydroMassage Bed or rear of HydroMassage Lounge RUN WATER AND POWER THROUGH WALL CONDUIT WHERE POSSIBLE COOLER WATER AND ELECTRIC LINES IN CONDUIT EXTERNAL TEMPERATURE CONTROL...

Page 32: ...L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 31 of 36 HydroMassage Chimney External Cooling System Heat Exhaust Optional for 450 series ...

Page 33: ... grease the touchscreen connecting post Second remove the touchscreen arm from the mount on the side of the bed Third clean with scotch bright pad and alcohol wipe IMPORTANT Apply synthetic grease with PTFE Teflon and re insert back into arm mount Every 12 Months 1 First drain and clean bed Second replace the distilled water and add 2 teaspoons of Defoamacide Instructions included both in the manu...

Page 34: ...nds 3 Plug back in the 220v power and the touchscreen will power on 4 Once the HydroMassage software loads on the touchscreen the HydroMassage unit will start initializing 5 Wait approximately 45 seconds to finish initializing Call Tech Support with any questions L 300 Bed Quick Start Manual V2 0 20180312 JTL Enterprises Inc 1 727 536 5566 www HydroMassage com Page 33 of 36 ...

Page 35: ... liability reasons HydroMassage technicians are not permitted to install or modify the External Cooling System above a customer s room Installation Follow the steps in the table below to professionally install HydroMassage unit s at a customer site NOTE Refer to the appropriate HydroMassage Quick Start Manual for full instructions Step Action 1 Review HydroMassage Post Installation Training sectio...

Page 36: ...s of all installed unit s Electrical wiring frame and water lines connecting ETCU to the HydroMassage Room placement wide angle view is recommended External cooling system if completing an Above the Room Installation 11 Provide staff training and guidance in the following area s prior to leaving site User Interface Operation Functionality IMPORTANT Include a 1 3 minute HydroMassage tour demo Clean...