AACH100

INSTRUCTION MANUAL

Before operating this appliance, please read this instruction 

manual thoroughly and keep on file for future reference.

1 HP 

 80-700 GALLONS 

(300 TO 2500L)

Summary of Contents for ACTIVE AQUA AACH100

Page 1: ...tem Reservoirs Ideal for ponic System Reservoirs AACH100 INSTRUCTION MANUAL Before operating this appliance please read this instruction manual thoroughly and keep on file for future reference 1HP 80 700GALLONS 300TO2500L ...

Page 2: ...ONTENTS INTRODUCTION 3 SUGGESTIONS FOR SAFE OPERATION 3 FEATURES 4 TECHNICAL DATA 4 PERFORMANCE CURVE 5 INSTALLATION 6 ASSEMBLY 7 OPERATION 8 9 MAINTENANCE CLEANING 9 10 TROUBLESHOOTING 11 PARTS LIST 12 CIRCUIT DIAGRAM 13 GUARANTEE 14 ...

Page 3: ... SUGGESTIONS FOR SAFE OPERATION Several symbols are used in this manual and on the product itself which are aimed at promoting proper and safe operation in order to prevent personal injuries or damage to the Chiller Please familiarize yourself with the symbols below before reading the manual or trying to operate the Chiller Terms And Symbols Hazard levels will be indicated in writing or shown by p...

Page 4: ...rigeration Water Refrigerated 2000L 74 F 1 F Refrigerant R22 Refrigerant Weight 420 450g Rate of Flow 1500 4000L h Reservoir Capacity 80 700 GAL 300 2500L Weight 69 lbs Size 21 x 15 x 21 1 The rate of flow is decided according to the max jet of the pump immersible pump or other external power filter and the circulation equipment 2 The refrigeration performance test is indicated when the ambient te...

Page 5: ... 88 F RESERVOIR CAPACITY 300L 2500L F PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 88 F 31 C THE WATER TEMPERATURE BEFORE REFRIGERATION IS 86 F 30 C AND THE WATER REFRIGERATED IS 500L 132 GAL 1000L 264 GAL AND 2000 L 528 GAL ...

Page 6: ...ce Fig 4 5 Do not cover or move the Chiller while it is operating 6 The circulation water flow of the Chiller is indicated in the technology parameter table This Chiller does not have a water pump so it needs a pump with an available external filter Using a pump without an external filter may cause a water leak or other damage Fig 6 7 Do not put the Chiller on its side or upside down as this will ...

Page 7: ...ired length of tubing onto each inflow and outflow fitting adapter with the worm drive hose clamps The inflow should connect the Chiller to the appropriate sized submersible water pump such as an ActiveAqua Water Pump in the proper sized reservoir see attached performance chart The outflow tube should hang freely in the reservoir to re introduce the chilled water back into the holding tank Please ...

Page 8: ...may inflict electric shock SETTING THE TEMPERATURE 1 Press and hold the SET button down for approximately 3 seconds to enter the water temperature programming mode The previous water temperature setting will display 2 Use the or buttons on the control panel to increase or decrease the desired water temperature Press the SET button once more or wait approximately 8 seconds to select the desired tem...

Page 9: ...posits and other debris may accumulate inside the Chiller reducing its effectivity see pg 10 Note Do NOT use soap or detergents for cleaning the internal components of the Chiller system 1 Disconnect the Chiller and submersible water pump from the power supply 2 Clean off the pump with a high powered hose or sprayer to remove debris and dirt from the pre filter and housing Clean the pre filter as ...

Page 10: ... to the front WE RECOMMEND THE FOLLOWING AIR FILTER MAINTENANCE PROCEDURE ON A REGULAR BASIS 1 LOOSEN SCREW ON FRONT PANEL 2 GENTLY REMOVE FRONT PANEL 3 4 LOOSEN FILTER SCREWS AND REMOVE FILTER 5 LIFT AND REMOVE SIDE PANEL 6 7 LOOSEN SCREW ON SIDE PANEL AND REMOVE FILTER 8 REMOVE DUST WITH BRUSH VACUUM OR RINSE WELL WITH WATER DRY THOROUGHLY BEFORE REINSTALLING THE PARTS IN REVERSE ORDER ...

Page 11: ...the water circulation is normal B If the fan and the Chiller dissipate heat normally wait for 3 minutes and the unit will automatically turn on again Fan is not working Return to place of purchase The set temperature is higher than the aquarium water temperature Reset temperature The air inlet or outlet are clogged Clean the air inlet outlet with a brush or a vacuum cleaner Not installed on a flat ...

Page 12: ...e hose clamps 2ea c Rubber replacement collars extras 2ea 1 Front panel 2 Filter Front 3 Control command panel 4 Front cover 5 Circuit board 6 Back cover of circuit board 7 Bushing 8 Side filter 9 Side cover 10 Nut 11 Condenser 12 Back cover 13 Handle 14 Fan motor 15 Compressor 16 Base 17 Tank with evaporator 18 Top cover ...

Page 13: ...tions so that the appropriate size pump may be implemented A pump that is either too weak or too powerful may impede the operation Vertical distance between the pump and the Chiller will affect the size of the pump that is needed I E If the pump only needs to project water 2 to get the Chiller unit compared to 10 a smaller pump can be used We recommend that the power source support ONLY the Chille...

Page 14: ...w instructions is not covered If you have a problem recheck your system and pump If this does not remedy the situation contact the original place of purchase for a war ranty assessment Unauthorized returns will not be accepted Save your receipt invoice a copy is required for all warranty work Please contact your place of purchase for warranty information 1 1 on reflective materials ...

Page 15: ......

Page 16: ...Made In China To Hydrofarm s Exacting Specifications Distributed By Hydrofarm Inc Petaluma CA www hydrofarm com ...