Installation and Operation:

1. Remove cabinet cover.   Drill holes for the three wall anchors with a 7mm drill bit, using the cabinet back as a template

for correct spacing of the mounting screws. Install mounting anchors, and then screws in top two anchors. Slide
key holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than
(1.8 metres) above the bottom of the concentrate container, nor below the highest concentrate level (never mount
your concentrate higher than the proportioner).

2. Select metering tips (up to 4) for the selector valve (see next two sections). Push each tip firmly into a separate hose

barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port
not being used. (This may be used for dispensing water only.) Select and install a metering tip for the single product
eductor (right side) in the same manner.

3. Cut tubing provided into separate supply tubes for each product to be dispensed (tubing allows for 200mm of tube

per product). Supply tubes should reach from hose barbs on the selector valve body and eductor to bottom of
concentrate containers. Slide ceramic weights over one end of each tube and slide foot valves into the same ends
of the tubes.

4. Slip open end of each supply tube through an opening in either side of the cabinet and push over a hose barb/

metering tip on the selector valve and on the eductor.

5. Place foot valve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE

STRAINERS PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.

6. A short discharge tube is used with the 4 LPM eductor (selector valve); minimum tube length is 20 cm for

correct operation. A longer tube (1.2m) is used with the 16 LPM eductor. Slide end of tube with flooding ring over
eductor discharge outlet. The hose hook supplied may be installed on the long tube to allow it to conveniently hang
from dispenser when not in use.

7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided

may be installed in the holes in the cabinet sides to prevent easy removal of cover.

8. Connect water supply hose of at least 13mm ID to water inlet swivel. (Minimum 1.76 Bar  pressure, with water running,

is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on.

9. Purge air from the system by depressing the buttons briefly.
10. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then

push the button whenever dispensing is desired, and release button to stop flow of solution. 

If you wish to be able

to lock the button in the "on" position:

 Clip or bend the two tabs behind the lower front  portion of the button.

(Seediagram.) This allows the button to be fully depressed and allows it to latch in the "on" position. 

To unlock, pull

the button out.

AccuDose

 Series Proportioner Model 3876GB-2

Package Should Contain:

1. Proportioner unit.
2. Supply tubing : 650mm total.
3. Foot valve assemblies & weights (5).
4. Discharge tube for each eductor.
5. Metering tip kits.
6. Mounting anchor kit.
7. Hook for 16 LPM discharge tube.
8. Instruction sheet.

Clip or
bend
these
tabs to
depress
button
into locked
position.

Summary of Contents for AccuDose 3876GB-2

Page 1: ...VE STRAINERSPERIODICALLYFORCLOGGING CLEANIFNECESSARY 6 A short discharge tube is used with the 4 LPM eductor selector valve minimum tube length is 20 cm for correct operation A longer tube 1 2m is used with the 16 LPM eductor Slide end of tube with flooding ring over eductor discharge outlet The hose hook supplied may be installed on the long tube to allow it to conveniently hang from dispenser wh...

Page 2: ... concentrate X 1 If the test does not yield the desired ratio choose a different tip and repeat the test Alternative methods to this test are 1 pH using litmus paper and 2 titration Contact your concentrate supplier for further information on these alternative methods and the materials required to perform them AccuDose Parts Diagram 5 7 8 4 2 3 1 6 1 238100 Strainer washer 2 10082835 Swivel collar...

Page 3: ...are for 16 LPM discharge tubes 17 10061100 Support 18 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 19 690014 Metering tip kit 20 500870 Tubing 6mm x 2 1 m 21 509900 Weight 22 10076301 Foot valve Viton EPDM also available Order 10076302 NOT SHOWN 641750 Security screws for cabinet sides Description Part No Key 9 10 11 12 13 14a 18 19 17 19 e 15a 22 21 20...

Page 4: ...water running required to operate unit properly d Discharge tube s not in place d Push tube firmly onto eductor discharge or flooding ring missing from hose barb be sure inner discharge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged...

Reviews: