background image

1

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

READ AND FOLLOW ALL INSTRUCTIONS

1.

DANGER:

 To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times.

2. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the

manufacturer.

3. Never drop or insert any object into any opening.
4. Do not operate this unit without the cover over the suction fitting.
5. The unit must be connected only to a dedicated electrical supply circuit that is protected by a Ground Fault Circuit

Interrupter (GFCI). The GFCI must be provided by the installer and should be tested on a routine basis by the homeowner.

To test the GFCI push the test button. The GFCI should interrupt power. Push the RESET button. Power should be restored.

If the GFCI fails to operate in this manner there is a ground current flowing, indicating the possibility of an electric shock.

Do not use the tub. Disconnect the power and have the problem corrected by a qualified service representative. Re-test

the GFCI, only when it is operating properly may the whirlpool tub be used.

6. A green colored terminal marked “Ground” is provided on the exterior of the control box. To reduce the risk of electric

shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a conductor equivalent

in size to the circuit conductors supplying this equipment.

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

USER MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

WARNING: WHEN USING YOUR HYDRO SYSTEMS TUB, BASIC PRECAUTIONS SHOULD BE FOLLOWED, SEE BELOW

Read all instructions before proceeding with installation.

Inspect the tub before installation. If any damage or defects are found, do not install the tub. If the tub is not the right

size, model or color do not install the tub. Contact tech support at 661-775-0686 or email [email protected]

INSTALLATION OF A THE METRO COLLECTION BATHTUB MUST MEET ALL APPLICABLE CODES AND REGULATIONS.

IMPORTANT- 
All tub and systems are thoroughly tested and inspected at the factory prior to shipment. However, it is possible for 
damage to occur during shipment and installation. Such damage is not always readily visible. To maintain the warranty, it 
is important to water test the tub, integral overflow and thermal system a minimum of 30 minutes for leaks during rough 
inspection before enclosing the tub. Hydro Systems is not responsible for the cost to remove/reinstall a tub.

CARE AND CLEANING-
To assure a long lasting “like new” look on your Metro Collection bathtub we recommend the following easy 
care procedures:

1)

For normal maintenance, especially after use, clean with a soft cloth or sponge and a mild soap or liquid detergent.

2)

DO NOT USE abrasives such as scouring compounds, scouring pads, steel wool or harsh chemicals on your

Hydro Systems bathtub. For deeper stains, hard scale deposits or any other cleaning or maintenance problem,

 contact your Hydro Systems dealer.

SAVE THESE INSTRUCTIONS FOR LATER REFERENCE

WARNING:

 

This product can expose you to chemicals including styrene, which is known to the State of California to cause 

cancer. For more information, go to www.P65Warnings.ca.gov.

Summary of Contents for Metro Collection

Page 1: ... USER MAINTENANCE INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING WHEN USING YOUR HYDRO SYSTEMS TUB BASIC PRECAUTIONS SHOULD BE FOLLOWED SEE BELOW Read all instructions before proceeding with installation Inspect the tub before installation If any damage or defects are found do not install the tub If the tub is not the right size model or color do not install the tub Contact tech support at 661 775...

Page 2: ...ring and withstands stains better than the other materials To keep this high quality look on your Metro tub please follow these instructions MATTE FINISH Remove dust with a soft damp cloth for example microfiber or calico cloths Clean surface with water and any mild detergent or dish soap For a more difficult stain such as oil paint ink or grease clean with rubbing alcohol and dry with a soft clot...

Page 3: ... Apply plumbers putty around the Drain Body and pass it thrugh the drain hole Figure 3 Apply rubber gasket and slide it over the bottom of the Drain Body Figure 3 Slide the rubber washer over the drain body Attach the drain Body to the ABS PVC Shoe fitting and tighten until the Gasket has created a seal with the bottom of the bathtub DO NOT OVERTIGHTEN Figure 4 6 7 8 9 FIGURE 3 FIGURE 4 FIGURE 5 P...

Page 4: ...17 FIGURE 8 FIGURE 6B FIGURE 6A INSTALL BATHTUB Apply generous bead of adhesive or silicone to the bottom of the tub supports Figure 6A Then apply a bead of tub and tile caulk or silicone around the edge of the base Figure 6B 16 14 15 FIGURE 7 Carefully set tub into position Figure 7 and connect the drain harware previously installed Please refer to www hydrosystem com for specific dimensions on y...

Page 5: ...s It is not recommended that the blower be mounted over 8 feet away from the tub The supplied wiring between the tub and the blower is approximately 10 feet long Remote blower locations There are several locations where the blower can be located There must be a GFCI electrical outlet within 2 feet of the blower The blower is approximately 9 25 inches long and 8 inches in diameter and 5 high Substa...

Page 6: ...install bell flange on overflow pipe Slide the bell flange high up on the overflow pipe to avoid heat damage during the next step 11 Carefully solder connections at brass tee Wrap a wet rag around overflow pipe to prevent the heat from damaging the plating Always use proper heat shielding to protect the surrounding materials 12 Connect the P trap to the drain kit 13 Use clear silicone to seal the ...

Page 7: ... WARRANTY OBLIGATIONS OF HYDRO SYSTEMS INC Should a defect in workmanship and or material in any item covered by this warranty become evident during the term of the warranty then upon the consumer following the procedures set forth below HYDRO SYSTEMS INC at its opinion will repair or replace such item at its own cost and expense HYDRO SYSTEMS INC is not however responsible under this warranty for...

Page 8: ...awings or improper installation 3 Problems resulting from abuse misuse negligence or accident by any party other than HYDRO SYSTEMS INC such as but not limited to damage to parts by installers 4 Problems resulting in whole or part from alteration or modification of these products by any party 5 Metal failures due to chemical corrosion This warranty is provided to you as part of your purchase order...

Reviews: