background image

B

C

D

D

A

E

F

P/N 0495781_C

D6X-ULEP

Technical Data Sheet

P/N  0495781_C

NSF

®

Certified

March 2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES

4 Ft, 8 Ft & 12 Ft

A.

12W Standard

Fan Assembly 

(1)

0047000

Fan Motor, Evaporator
(MO.4410103)

0461805

Fan Blade (FB.4780446)

12W Energy Efficient

Fan Assembly 

(1)

0477655

Fan Motor, Evaporator 
(MO.4410546)

0461805

Fan Blade (FB.4780446)

6 Ft Only 

A.

7W Standard 

Fan Assembly  

(1)

0058698

Fan Motor, Evaporator
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient

Fan Assembly 

(1)

0477654

Fan Motor, Evaporator
(MO.4410545)

0142780

Fan Blade (FB.0142780)

Item Part #

Description

Wiring Item #

T

HERMOSTATS

B. Optional Adjustable Refrigeration Thermostat (2)

L

AMPS AND

B

ALLASTS

C. Ballast, Electronic

(3)

0480130

2 lamps (BA.4481676)

0480131

3 lamps (BA.4481654)

0480132

4 lamps (BA.4481677)

D.

Fluorescent Lamp

(4)

Replace with like fixtures

E. 0501213

Power Supply (EP.4481861)

(5)

F.

LED Fixture

(6)

Replace with like fixtures

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

ONE FLOOR DRAIN IS

REQUIRED FOR EACH CASE.

IMPORTANT

Note: Revision C adds Important Note on Page 1, adds optional LED lighting (

Pages 1, 3, 4, 8

); 

adds capacity and weight (

Page 5

)

Summary of Contents for IMPACT Excel D6X-ULEP

Page 1: ...y A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 LAMPS AND BALLASTS C Ballast Electronic 3 0480130 2 lamps BA 4481676 0480131 3 lamps BA 4481654 04801...

Page 2: ...er of LH waste outlet 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 RH End of case to the center of RH waste outlet 12 1 8 307 12 1 8 307 12 1 8 307 12 1 8 307 Back O S of case to center of waste outlets 36 3 4 933 36 3 4 933 36 3 4 933 36 3 4 933 Schedule 40 PVC drip pipe 1 1 4 32 1 1 4 32 1 1 4 32 1 1 4 32 Refrigeration Outlet Back of case to center of refrigeration outlet 26 1 4 665 26 1 4 66...

Page 3: ...IG conversions PHYSICAL DATA Estimated Charge lb D6X ULEP 4 ft 1 9 6 ft 2 8 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0495781_C HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM Impact Excel D6X ULEP Dairy Delicatessen Dimensions shown as in and mm Multi deck 6 Display Levels Ultra L...

Page 4: ...ent 0 80 0 96 1 40 2 00 230V 60Hz Energy Efficient 0 50 0 60 0 80 1 10 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 53 1...

Page 5: ...1 02 m3 m ARI Total Display Area 3 Sq Ft Ft 5 67 ft2 ft 1 73 m2 m Shelf Area 4 Sq Ft Ft 9 87 ft2 ft 3 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Len...

Page 6: ...ue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND 4 4 3 3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 4 3 4 4 Connector W B ...

Page 7: ...ST ITEM NUMBERS CASE GROUND W W B B Optional Shelf Harness and Light Circuits for Seven Rows of Shelves 4 ft case Connector B W Connector 6 ft or 8 ft case 12 ft case W B W B B W 4 4 R R BL BL R BL BL R 3 3 4 4 4 BL BL R BL BL BL R R R BL BL BL R R R R 4 4 R R BL BL R BL BL R 4 4 R R BL BL R BL BL R 3 3 4 4 4 BL BL R BL BL BL R R R BL BL BL R R R R 4 4 R R BL BL R BL BL R W B W B B W 4 4 R R BL BL...

Page 8: ...le B Connector R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harn...

Reviews: