background image

B

D

D

E

C

E

A

P/N 0504418_A

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

7W Standard 

Fan Assembly

(1)

0058698

Fan Motor, Evaporator
(MO.4410102)

0142780

Fan Blade (FB.0142780)

7W Energy Efficient 

Fan Assembly

0439052

Fan Motor, Evaporator
(MO.4410110)

0142780

Fan Blade (FB.0142780)

7W Export 

Fan Assembly

0436516

Fan Motor, Evaporator
(MO.4410106)

0142780

Fan Blade (FB.0142780)

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat
(CT.0411744)

C. Optional Adjustable Refrigeration Thermostat

(3)

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. Ballast, Electronic

0466234

2 lamps (BA.4480823)

(4)

0466235

3 lamps (BA.4480901)

0466236

4 lamps (BA.4481095)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

We reserve the right to change or revise
specifications and product design in
connection with any feature of our products.
Such changes do not entitle the buyer to
corresponding changes, improvements,
additions or replacements for equipment
previously sold or shipped.

E3S

Technical Data Sheet 

P/N  0504418_A

NSF

®

Certified

April  2008

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Summary of Contents for IMPACT Elite E3S

Page 1: ...rigeration Thermostat 3 Item Part Description Wiring Item LAMPS AND BALLASTS D Ballast Electronic 0466234 2 lamps BA 4480823 4 0466235 3 lamps BA 4480901 0466236 4 lamps BA 4481095 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to correspo...

Page 2: ... end of wireway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of wireway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Outlet F RH End of case to the center of waste outlet 24 1 4 616 24 1 4 616 24 1 2 622 72 1 4 1834 LH End of case to the center of waste outlet 23 7 8 606 47 7 8 1216 71 3 4 1822 72 1 8 1832 Back O S of case to center of waste outlet 27 5 8 702 27 5 8 702 27 5...

Page 3: ...t Termination Temp F 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb E3S 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound 3 of 8 P N 0504418_A 20 3 8 518 30 762 54 1372 12 305 18 1 2 470 34 1 2 876 46 1 2 1181 12 305 27 5 8 702 30 3 4 781 31 787 FAN C O I L 34 8...

Page 4: ...1 20 1 70 120V 50Hz Standard 0 75 1 30 1 30 1 85 230V 60Hz Export 0 45 0 70 0 70 0 95 230V 50Hz Export 0 48 0 76 0 76 1 04 120V 60Hz Energy Efficient 0 39 0 58 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 40 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 208V Electric Defrost Heaters NA Standard Lighting T 8 fluorescent 2 Rows of Canopy 0...

Page 5: ...m2 m Shelf Area 4 Sq Ft Ft 7 10 ft2 ft 2 16 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf surface area is composed of bottom deck plus...

Page 6: ...Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G G G R BL 5 BL Connector Connector B R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Page 7: ...POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R 5 R R Light Circuits R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM N...

Page 8: ... illustration shows recommended shelf depth and shelf angle for the three locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Impact Elite E3S Delicatessen Precut Pa...

Reviews:

Related manuals for IMPACT Elite E3S