background image

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

7W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator 

142780

Fan Blade,
embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0353949

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0466234

Ballast, Electronic

2 lamps

(4)

D. 0466235

Ballast, Electronic

3 lamps

(4)

D. 0466236

Ballast, Electronic

4 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

B

D

C

E

A

E

D

P/N 0453524A

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Note: Changed items have been underlined.

E2S

Data Sheet Set

P/N  0453524A

NSF

®

Certified

October  2005

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for IMPACT Elite E2S

Page 1: ...66235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures B D C E A E D P N 0453524A HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Changed items have been underlined E2S Data Sheet Set P N 0453524A NSF Certified October 2005 We reserve the right to change or revise specifications and product design in connection with any fea...

Page 2: ... of end knockout 29 5 8 752 29 5 8 752 29 5 8 752 29 5 8 752 D RH End of case to RH end of raceway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of raceway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Outlet F RH End of case to the center of waste outlet 24 1 4 616 24 1 4 616 24 1 2 622 72 1 4 1834 LH End of case to the center of waste outlet 23 7 8 606 47 7 8 1216 71 3 4 182...

Page 3: ...perature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2S 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length in Added to Lineup by Each End or Insulated Partition 1 3 of 7 P N 0453524A HUSSMANN CORPORATION...

Page 4: ... 0 56 0 56 0 84 44 89 89 132 Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export Fans 230V 50Hz 0 48 0 76 0 76 1 04 Maximum Over Current Protection 20 20 20 20 Export 230V 50Hz 15 15 15 15 Electric Defrost Heaters 208V 1Ph NA Standard Lighting 2 Rows Canopy 0 51 1 01 1 01 1 52 ...

Page 5: ...s must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...S LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R BL BL 4 5 5 R 5 R 5 5 5 4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps B R 4 ft case has 1 Lamp 6 ft case has 2 Lamps 8 ft case has 2 Lamps 12 ft case has 3 Lamps ...

Page 7: ... the two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Impact Elite E2S Delicatessen Precut Packaged Produce Load Limit 12 in 10 Recommended Angle Shelf Size 1...

Reviews: