Alternatively, you may want to take a picture of the wires on your old thermostat for reference. 

If you have any wire codes that do not match the Hunter labels,  you may have a system that 

does not conform to industry standard. Call our Technical Support at 1-888-830-1326.

Getting Started

1. Power OFF Your  HVAC System Unit

You will need a Phillips head screwdriver to complete this installation.

 

Read and save these instructions! 

If you still need assistance after reading this manual, call our Technical Support at 

USA: 1-888-830-1326     Canada: 1-866-268-1936

This thermostat is compatible with most 24V AC/millivolt systems with a maximum of 1 amp including: conventional oil, 

gas, electric, hot water systems, single stage, and multi-stage heat pumps. This thermostat will not control line voltage 

systems running 110V. Higher amp or line voltage systems will increase the risk of fire.

*This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 
*This device complies with RSS-GEN IC: Operation is subject to the following two conditions: (1) this device may not cause interference, and 

(2) this device must accept any interference, including interference that may cause undesired operation of the device.

*Any alteration of this product, either intentional or unintentional, not expressly approved by the manufacturer could result in operation 

failure of the device, inability to gain assistance from our technical team, or manufacturer refusing warranty support. 

*This Class B digital apparatus complies with Canadian ICES-003.

*Only 1 reversing valve is needed to run a heat pump. If both “O” and “B” are present, “B” may be a common wire.

Expose your existing thermostat wires.

Locate the wire terminals. If the wire terminals 
are not visible, they may be connected to the 
back of the wall plate. 

Remove the existing wall plate and/or thermostat

Label your wires. 

As you remove each wire one at a time, find 
the Hunter label with the corresponding 
letter code and attach it to the wire. 

DO NOT DISCONNECT THE WIRES 

BEFORE LABELING THEM

3. Mounting Your Wall Plate

Insert the wires. 

Pass your labeled wires through 

the opening of the wall plate

.

Separate the wall plate. 

Pull the wall plate straight off 

the back of your thermostat.

RH, R

Power wire for heating

Install the top screw. 

Partially tighten one 

screw into the top hole.

Level the wall plate.  

Install the bottom screw. 

Fully tighten both screws.

Go to your circuit breaker panel and turn off 

power to your compressor and furnace.

   Wire Identification

OFF

Turn Power

A

C

C

D

2. Labeling Your Wires

A

B

RC

Power wire for air conditioning 

Y, Y1

Controls your compressor outside

G

Controls your fan to your HVAC system

W

Furnace wire

L

Allows the heat pump to tell 
the thermostat there may be a 
system problem

O

Reversing valve for the heat 
pump; allows compressor to 
supply air conditioning*

B

Alternate reversing valve 
for the heat pump; allows 
compressor to supply heat*

W2

 - Second stage of heat 

E

 - Emergency heat 

Aux

 - Auxiliary wire

Y2

Second stage of cooling

C

Common wire used to 
power the thermostat 
when available

A

Only used with a 3 wire hot 
water heating system

Pre-Installed 

Jumper Clip

Tip: 

You may need a precision screwdriver (smaller tip) to detach wires from your old thermostat.

Tip: 

 To prevent your wires from falling back into the wall, wrap them around a pencil.

B

Summary of Contents for 44920

Page 1: ...3 Only 1 reversing valve is needed to run a heat pump If both O and B are present B may be a common wire Expose your existing thermostat wires Locate the wire terminals If the wire terminals are not visible they may be connected to the back of the wall plate Remove the existing wall plate and or thermostat Label your wires As you remove each wire one at a time find the Hunter label with the corres...

Page 2: ...OPTION 2 Snap your thermostat onto the wall plate D Install your AA batteries Note NEVER use rechargeable batteries C Write down your 15 digit security code exactly as displayed You will need this code when you setup your account B A Set your system switches Based on the type of furnace you have Select Gas Oil or Electric Select Heat Pump or Conventional 6 Power ON Your HVAC System Unit You have c...

Page 3: ...inversion alternative pour la pompe à chaleur permet au compresseur de fournir le chauffage W2 Deuxième étage de chauffage E Chauffage d urgence Aux Fil auxiliaire Y2 Deuxième étage de climatisation C Fil commun utilisé pour alimenter le thermostat si disponible A Utilisé seulement avec un système d eau chaude à 3 fils Cavalier déjà installé Conseil Il faudra peut être un tournevis de précision tê...

Page 4: ...e JAMAIS utiliser de piles rechargeables C Prendre note du code de sécurité à 15 chiffres exactement comme il est affiché Ce code sera nécessaire pour établir votre compte B A Régler les commutateurs de système Selon votre type de fournaise Choisir Gas Oil gaz mazout ou Electric électrique Choisir Heat Pump pompe à chaleur ou Conventional conventionnel 6 Mettre en marche le système CVC L installat...

Reviews: