background image

 

BA 879 410-led HM; DE, GB - 23642 - 2016.05-V01 

Hugo Müller GmbH & Co KG

Sturmbühlstraße 145-149

D-78054 VS-Schwenningen

Tel.: +49 (0) 7720 80 836

Fax: +49 (0) 7720 31 083

[email protected]

www.hugo-mueller.de 

 

INSTRUCTION MANUAL TRIAC DIMMER [R,L] – 879 410 LED 

Technical Features 

Safety instructions 

Supply voltage 

230 V, 50 Hz   

 

 

CAUTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!

 

 

Installation and assembly of electrical equipment must be carried out only by  

         professional electrician! 
 

Connect to supply voltage/frequency as stated on the product! 

 

Disconnect device from power supply for wiring and installation purposes! Check power supply is disconnected! 

 

Defective devices have to be put out of service immediately! 

 

Warranty void if housing opened by unauthorized person! 

 

Electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if external influences exceed certain limits! 

 

Installation and assembly of electrical equipment must be in accordance with local building and electrical codes!

 

Important note 

 

When calculating the max. load please take into account power dissipation of transformers: For conventional transformers ~20% power dissipation / 

For electronic transformers ~2% power dissipation. 

 

For all transformers and lamps, please take into account the specifications of the manufacturer! 

Intended use 

 

The device fits for the particular use of the following tasks: dimmer for the previously defined lamps. 

 

Operate the device in a closed room only! The regulation of the brightness operates as described in the instruction manual. 

 

The device is equipped with a overheat protection and short-circuit protection.  

Power consumption 

3 VA 

Type of lamps 

dimmable LED lamps 

LOAD

S

 

Dimmable 230 V LED lamps 
for leading edge  

4 - 1200 W 

Max. number of pushbuttons 

unlimited 
(no illuminated pushbuttons) 

Dimensions 

87,5 x 87,5 x 60 mm 

Weight 

400 g 

Working temperature  

0 º … +40 ºC 

Storage temperature 

-30 º … +70 ºC 

Type of protection 

IP20 nach DIN EN 60529 

According to the norm 

DIN EN 60669-2-1 

 

 

Description / Installation  

 

Operation 

Description / Intended use 

 

TRIAC dimmer for DIN-rail mounting  

 

Use with dimmable LED lamps 

 

For leading edge 

 

The device is equipped with a overheat protection and short-circuit protection.  

 

Unlimited number of pushbuttons (no illuminated pushbuttons), potentiometer (internal or external) or 0 - 10V 

signal. 

 

Seven basic functions (MEM, NO MEM, MEM PLUS, 0 - 10V, SLAVE, int. & ext. potentiometer). 

 

Check the technical specification of the lamps! For all transformers and lamps, please take into account the 
specifications of the manufacturer! 

 

Installation  

 

CAUTION! 

 

You must select the correct type of connected load in order to avoid damages of the 

dimmer or the lamps!

 

1.  Set an operating mode with the lateral rotary knob. 

2.  Disconnect device from power supply for wiring and installation purposes! Check power supply is 

     disconnected! 

3.  Mount the dimmer on the DIN-rail of the electric cabinet. Avoid placing it next to other sources of heat. 

4.  Carry out the wiring according to the selected operating mode. 

5.  Reconnect the power supply. The dimmer is ready for operation. 

 

Anti-panic function 

If you open the contact between the two terminals, the dimming function 

overloads and the installed load/loads illuminate with maximum power. 

You need this function especially in emergency situations. With removing 

the bridge, the dimmer goes to maximum load and does not react to standard commands. If you do not use this 

function, you have to keep the bridge between the terminals closed. The dimmer works in the standard mode 

then. 

Operation / functionality 

The dimming can be performed with different controls, depending on the 

configuration selected:  

 SLAVE        Master-Slave Mode 

          Potentiometer (intern or extern) 

MEM            Pushbutton operation – Memory function 

NO MEM      Pushbutton operation – No memory function 

MEM PLUS  Pushbutton operation – Memory function with 

                    additional safety function in case of power failure 

0-10V           Signal 0 - 10V 

 
 

Protection against over heat 

 Protection against over heat switches off the lamps. 

Note:

 If the dimmer is switched off due to over heat protection, please try to: 

 

Reduce the output load. 

 

Install the dimmer inside an electric cabinet with forced ventilation or without other heat sources, 

 

or place it in the lower part of the cabinet, where the accumulation of heat may be lower. 

 

Selector switch for LED lamp type 

The device has a selector switch with 3 modes of operation: LEDA, LEDB, LEDC.  

 Change the selected mode if you notice that the LED lamps blink or change light level 
 suddenly at 
 some point of the dimming. Select the mode that fits to the characteristics of your LED 
 lamp best. 

Reviews: