OptiXstar P622E

Quick Start

Issue

01

Date

2019-09-30

HUAWEI TECHNOLOGIES CO., LTD.

Summary of Contents for OptiXstar P622E

Page 1: ...OptiXstar P622E Quick Start Issue 01 Date 2019 09 30 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...s document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of th...

Page 3: ...arance 1 2 Installing the Device 2 3 Connecting Cables 10 4 Description of Indicator 12 5 Technical Specifications 14 6 FAQs 15 OptiXstar P622E Quick Start Contents Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd ii ...

Page 4: ...e If the appearance of the product in this document differs from the actual product the actual product prevails OptiXstar P622E Quick Start 1 Product Appearance Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 1 ...

Page 5: ...l running voltage 385 V AC 3 The protecting voltage 1 8 kV 2 Other requirements for the installation of a surge protector 1 Impedance 10 Ω for the network box from the ground 0 1 Ω for the surge protector from the ground bar 2 Ensure that network box is reliably grounded and ground cable is shorter than 50 m Use a cable of longer than 5 m to connect the surge protector of the input port of the pow...

Page 6: ...sktop flat wall mounted and network box installation l The heat dissipation sides are not allowed to have any contact with the wall or desktop Mounting on the desktop Do not stack the device when it is placed on the desktop OptiXstar P622E Quick Start 2 Installing the Device Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 3 ...

Page 7: ... outer diameter of the screws Use a hammer drill to drill the marked positions on the wall Then clean the holes and install two expansion bolts It is recommended that the screw diameter be less than or equal to 4 mm the nut diameter be 6 to 8 mm and the length should not be less than 20 mm 3 Use a screwdriver to fasten the screws into the expansion bolts reserving 5 mm ends out of the wall and mou...

Page 8: ... that the drips fallen vertically cannot damage the device l If the network box is installed outdoors or in a corridor that is exposed to rain the network box must meet the requirements of IP55 protection 5 means that the network box cannot completely prevent dust from entering but the amount of dust that enters the network box does not damage the device 5 means that the water sprayed from differe...

Page 9: ...orridor of the building does not meet the grounding requirement ground the network box through an external ground cable PGND cable and ensure that the strength member of the optical fiber is disconnected from the device ground point Decouple the surge protector from the ONU power source using a power cable of 3 5 m l Guide for Grounding the Network Box of the TT Power Distribution System In the ca...

Page 10: ...with engineering specifications If solution 2 is used the network box must be securely grounded In addition a metal protective cover must be installed between the fiber strength member and network box fixing points preventing sparks from spreading if the fiber strength member connects to a heavy current power line Customer Solution 1 If the engineering does not comply with solution 1 the customer ...

Page 11: ...s i Strip the outer insulation layer and armored tube from the fiber strength member at the ground point Then clean bare optical fibers and use a protection tube to protect them Use outdoor tubes in outdoor scenarios and common tubes in indoor or corridor scenarios Use waterproof tape produced by 3M or COTRAN ii Use a piece of sandpaper to polish burrs at the stripped position of the optical cable...

Page 12: ...r strength member must be connected to a ground bar at the ground point using a ground cable The ground point can connect to the network box using a metal in an equipotential manner When the fiber strength member connects to a heavy current power line heavy currents may be discharged inside the network box using the ground bar If this happens sparks may occur at the contact point between the fiber...

Page 13: ...l it switches to the signal from the SFP port Ports and buttons Description PON Supports GPON uplink access the port type is SC UPC SFP Connects to the ports on an SFP optical module support GPON uplink access GE1 GE4 Connect to a PC IP STB or camera to support 10Mbit s or 100Mbit s or 1000Mbit s interface rate adaptation Power Connects to a power adapter OptiXstar P622E Quick Start 3 Connecting C...

Page 14: ...Ports and buttons Description On Off Powers the ONU on or off OptiXstar P622E Quick Start 3 Connecting Cables Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 11 ...

Page 15: ...ernet port Off The Ethernet connection is not set up The status of PON and LOS reflects the connection between ONU and the optical line terminal OLT The following table describes the status of the PON and LOS LEDs Table 4 2 Indicator status description 2 Stat us No PON Status LOS Status Description 1 Off Off The ONT is prohibited by the upper layer device or blinks abnormally Contact the service p...

Page 16: ... layer device 5 Off Blinks once every 2 seconds The ONT is not connected to fibers or does not receive optical signals 6 Blinks once every 2 seconds Blinks once every 2 seconds The hardware is faulty OptiXstar P622E Quick Start 4 Description of Indicator Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 13 ...

Page 17: ...wer adapter input 11V to 14V typical 12 V 1A System power supply 100V to 240V AC 50 60Hz Maximum system power consumption 5 5 W Operating temperature 40 C to 55 C Operating humidity 5 RH to 95 RH non condensing OptiXstar P622E Quick Start 5 Technical Specifications Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 14 ...

Page 18: ...ge is displayed l If no operations are performed within 5 minutes after logging in to the web page the system times out and the system automatically returns to the login state l Enter the wrong user name and password 3 times consecutively the system will be locked and automatically unlocked after one minute l After logging in to the web page using the initial user name and password please change t...

Page 19: ...he optical port and optical fiber is properly connected l The ONU fails to register with the upper layer device Contact the service provider for help OptiXstar P622E Quick Start 6 FAQs Issue 01 2019 09 30 Copyright Huawei Technologies Co Ltd 16 ...