background image

1

HE17x Series

USB Data Logger User Manual

Summary of Contents for HE17 Series

Page 1: ...1 HE17x Series USB Data Logger User Manual...

Page 2: ...ll Battery 6 1 11 Fix USB Data Logger 6 Chapter 2 Logpro Software 7 2 1 The Requirement of the Computer Hardware 7 2 2 Install Driver Software 7 2 3 Setting the logger s properties to start a new meas...

Page 3: ...of and dustproof standard IP67 resisting moisture and dust Can set temperature and humidity limit value and LED lights will flash when the value being exceeded Lower consumption design 1 2AA 3 6V Lith...

Page 4: ...e Value Exceeds Setting Limits Fixed Bracket USB Connection Port Model Label Waterproof Ring 1 6 USB Temperature Data Logger Screen HE170 HE171 HE172 1 3 8 2 4 5 6 7 Display the High Limit Display the...

Page 5: ...When the Temperature or Humidity Value Exceeds the Setting Limits Fixed Bracket USB Connection Port Model Label Waterproof Ring 1 8 USB Temperature Humidity Data Logger Screen HE173 HE174 1 2 3 4 5 6...

Page 6: ...e logger 2 Check the MAX MIN High Low values as well as the current value in the working status 1 10 Install Battery 1 Open the Battery Cover 2 Remove shell 3 Install Battery 1 2 3 1 11 Fix USB Data L...

Page 7: ...5 USB Port 1 2 2 Install Driver Software 1 Install Driver Put the assigned software disc into the computer driver and open the file to find and select the driver based on the operating system OS Win7...

Page 8: ...ugged and plugged back too fast When unplugging the logger wait for about 5 seconds before plugging it in again If you unplug and plug back a device too quickly the computer may stop recognizing any U...

Page 9: ...ay Start Wait Delay Time then start log Timing Start Start log when Delay Time HHMMSS e g 170000 means 17 00 00 Delay Time Input a Delay Time or Timing Time High Low Limit CH1 Temperature CH2 Humidity...

Page 10: ...ay time the unit is second For example fill in 120 indicates that the instrument starts to record the data after turn on logger two minutes Timing start fill in the timing time and fill in the format...

Page 11: ...button to drag a box when the left mouse button is released the graph will be redraw with the data in the selected rectangle area Magnified data table Click right button then the graph will be redrawi...

Page 12: ...is calculated from temperature humidity The data pane lists the data samples collected by the logging device The column width of each column is adjustable by using the left mouse button and dragging t...

Page 13: ...uble click left mouse button then the selected file is opened Click right mouse button a popup menu is shown as below you can rename or delete or log file The save file is saved in the Logpro software...

Page 14: ...sulted from environment temperature please immediately take the logger out of the environment 4 2 Data Time Error Reason The battery level is low The data logger is not synchronous properties before s...

Reviews: