background image

Instruction Manual

Thermal Imaging Camera

Dongguan Xintai Instrument Co.,Ltd.

Add: Building F, No. 22 Yuhua Street, Hongye Industrial Zone,
Tangxia Town, Dongguan City, Guangdong Province
Postcode:523710
Tel:+86-769-82612006
Fax:+86-769-82612005
Website:www.hytechcn.com.cn    www.xintest.com.cn
www.xintest.en.alibaba.com
Email:[email protected]

User Manual Version 1.0. March 5

2019.

HT-04D       HT-04

(new)

Summary of Contents for HT-04

Page 1: ...22 Yuhua Street Hongye Industrial Zone Tangxia Town Dongguan City Guangdong Province Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hytechcn com cn www xintest com cn www xintest en alibaba com Email kevin xintest com cn User Manual Version 1 0 March 5 2019 HT 04D HT 04 new ...

Page 2: ...f image overlapping 1 2 Application of Image overlapping 2 Introduction to image sub menu 2 1 View image 2 2 Delete images 3 Introduction to color palette sub menu 3 1 Color palette description 23 24 25 26 27 28 28 30 28 28 28 31 29 24 3 2 Application of color palette 4 Introduction to emissivity sub menu 4 1 Emissivity description 4 2 Emissivity setting 4 3 The emissivity value of common material...

Page 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 7: ... professional optical glasses Lens maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Page 8: ...y level is low the top right of the screen will display Please charge in time through Micro USB interface When the product is off you can charge www xintest com cn 11 www xintest com cn 12 Infrared image resolution Visible image resolution LCD resolution Field angle Shortest focus length Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images ...

Page 9: ...idity Working time Built in chargeable 18650 battery Detachable Selectable 5 minutes 20 minutes not power off automatically 0 to 45 20 to 60 85 RH 2 3 hours JPG Setting command Language Unit language date time information USB Micro USB 2 0 1 www xintest com cn 13 www xintest com cn 14 Color palette Storage capacity Rainbow iron oxide red cold color black white white black Built in 3G above 20 thou...

Page 10: ...ft corner of the screen Battery Micro USB Please open the cap in use 2 www xintest com cn 15 www xintest com cn 16 The highest temperature cursor used to indicate the highest temperature position in the screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen Maximum value minimum value of f...

Page 11: ...the screen shows the thermal imaging status Witching between infrared thermal image and visible image press or key to switch the degree of fusion between inferred thermal images and visible images the degree of fusion is 0 25 50 75 and 100 Note Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures Hold down the image capture key for ...

Page 12: ...ding mode Note If there is no operation for more than 6 seconds the image blending mode will be automatically exited The function to hide highest lowest temperature column at the screen bottom under the operation after normal start up press key and the screen bottom will display highest lowest temperature column Press can also hide it Image output The saved images through capture may be checked an...

Page 13: ... main menu and select image in the main menu 171229 105030 171229 105031 171229 105032 171229 105033 The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best wit...

Page 14: ...tively So it is easy to obtain relatively correct measurement value The emissivity is usually set as 0 95 when the coarse objects that are easy to give out energy For semi matte objects that give out less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually s...

Page 15: ...missivity value through the self define option please refer to the table of emissivity of common materials Thermal radiation Black cloth Human skin Foam Charcoal dust Paint Matte paint Black rubber Plastic Timber Paper Chromium hemitrioxide Copper oxide Ferric oxide Textile Substance Thermal radiation Substance Bitumen Concrete Cement Sand Earth Water Ice Snow Glass Ceramics Marble Gypsum Mortar B...

Page 16: ... the setting sub menu After entering the Settings sub menu select MENU automatic shutdown press navigationThe button in the button enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or ...

Page 17: ...eturn Press MENU exit from the menu As shown in the figure after selecting cold hotspot press the button in the navigation key to enter the cold hotspot setting As shown in the figure after selecting set time press in the navigation key to enter the setting time Press key to select enable or disable the option Then press SELECT ENTER key to determine selection After the setting is completed press ...

Page 18: ...ng device cannot start The thermal imaging device powers off automatically Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new battery or charge it The power of the battery is used up Replace with new battery or charge it The time set for automatic power off is due Restart or change the time for automatic power off after rest...

Reviews: