Page 4: ... ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESSFOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material The only warranties for HP products and services are set forth in the express ...

Page 5: ...5 2 Installing the Switch 408 Included Parts 2 1 Japan Power Cord Warning 2 2 Installation Procedures 2 2 Summary 2 2 Installation Precautions 2 3 1 Prepare the Installation Site 2 5 2 Verify the Switch Passes Its Self Test 2 6 3 Mount the Switch 2 8 4 Connect the Switch to a Power Source 2 9 5 Connect the Network Cables 2 9 Sample Network Topologies 2 10 As a Desktop Switch 2 10 As a Segment Swit...

Page 6: ...nications 3 6 ProCurve Customer Support Services 3 6 A Specifications Physical A 1 Electrical A 1 Environmental A 1 Connectors A 2 Safety A 2 B Cables and Connectors Twisted Pair Cable Connector Pin Outs B 1 Straight Through Twisted Pair Cable B 2 Crossover Twisted Pair Cable B 3 Twisted Pair Cable Pin Assignments B 4 C Safety and Regulatory Statements Safety Information C 1 Informations concernan...

Page 7: ...ety Information Japan C 7 Safety Information China C 8 EMC Regulatory Statements C 9 U S A C 9 Canada C 9 Australia New Zealand C 9 Japan C 10 Korea C 10 Taiwan C 10 European Community C 11 Regulatory Information China C 12 D Recycle Statements Waste Electrical and Electronic Equipment WEEE Statements D 1 ...

Page 8: ... This page is intentionally unused ...

Page 9: ...his switch will be abbreviated as the Switch 408 The Switch 408 has eight auto sensing 10 100Base TX RJ 45 ports With this switch you can build a switched network infrastructure by connecting it to hubs other switches or routers or you can connect directly to computers printers and servers to provide dedicated bandwidth to those devices This chapter describes your Switch 408 including Front and ba...

Page 10: ...of the ports have the HP Auto MDIX feature which means that either a straight through or cross over cable can be used for any connection to another device and the switch automatically adjusts the pin assignments to complete the connection C Fault LED Power LED 10 100Base TX RJ 45 ports all ports have the HP Auto MDIX feature Link Act FDx and 100 LEDs for each port ...

Page 11: ...or more information Link Act green overlaid with the port number On Indicates the port is operating correctly and receiving a link signal from the connected device Off One of these conditions exists no active network cable is connected to the port the port is not receiving a link signal Flickering Indicates that there is network activity on the port FDx green On The corresponding port is operating...

Page 12: ... switch it is powered on when the AC power adapter is plugged in to an active power source and to the switch Caution Use only the AC power adapter supplied with the switch Use of other adapters including adapters that came with other HP network products may result in damage to the equipment 12 13V 1 0 0 8A power connector ...

Page 13: ...is needed to connect to an end node or to another switch or hub plug and play networking all ports are enabled just connect the network cables to active network devices and your switched network is operational automatic learning of the hardware addresses in the switch s 1000 entry address forwarding table auto negotiation of half full duplex on all ports auto negotiation of flow control for ports ...

Page 14: ...the packet is filtered out The switch thereby isolates local traffic so the rest of the network connected to the switch does not use bandwidth dealing with unnecessary traffic flood whenever a new destination address is found in a packet received on a port the destination address will not yet be in the switch s address table and the Switch 408 cannot know whether to forward or filter out the packe...

Page 15: ... under a horizontal surface Contact your HP Networking products reseller to order the mounting kit This chapter shows you how to install your Switch 408 Included Parts The Switch 408 has the following components shipped with it ProCurve Switch 408 Installation Guide 5991 6250 this manual Customer Support Warranty booklet Four rubber feet AC power adapter one of the following Australia New Zealand ...

Page 16: ...must be able toauto negotiate the duplex mode or be fixed at half duplex See page 2 4 See page 2 3 for installation precautions 2 Verify that the switch passes its self test This is a simple process of plugging the switch into a power source and observing that the LEDs on the switch s front panel show correct operation See page 2 7 3 Mount the switch The Switch 408 can be mounted on any horizontal...

Page 17: ...source When installing the switch since the unit does not have an On Off power switch an AC power outlet must be located near the switch and should be easily accessible in case the switch needs to be powered off Make sure the switch does not overload the power circuits wiring and over current protection To deter mine the possibility of overloading the supply circuits add together the amperage rati...

Page 18: ...at the bottom and progressively lighter devices installed above Connect no devices that have a fixed full duplex configuration Because the switch 408 complies with the IEEE 802 3u standard if a device connected to the switch hasa fixed configurationoffull duplex the device will not connect correctly to the switch Make sure all devices connected to the Switch 408 are configured to auto negotiate or...

Page 19: ...Table 2 1 Summary of Cable Types to Use with the Switch Installation Location Before installing the switch plan its location and orientation relative to other devices and equipment At the front of the switch leave at least 7 6 cm 3 inches of space for the twisted pair cabling At the back of the switch leave at least 2 6 cm 1 inch of space for the adapter s power cord Port Type Cable Type Length Li...

Page 20: ...the switch and then plug the AC power adapter into a nearby properly grounded electrical outlet 2 Check the LEDs on the switch The LED behavior is described on the next page Note The Switch 408 does nothave a power switch It is powered on when the AC power adapter is connected to the switch and to a power source Caution Use only the AC power adapter supplied with the switch Use of other adapters i...

Page 21: ...LEDs are on When the self test completes successfully The Power LED stays on and the Fault LED goes off The port LEDs Link Act FDx and 100 go into their normal operational mode If the LED display is different than what is described above especially if the Fault LED stays on for more than 5 seconds the self test has not completed correctly Refer to chapter 3 Trou bleshooting for diagnostic help C S...

Page 22: ...You may want to secure the networking cables and switch power cord to the table legs or other part of the surface structure to help prevent people from tripping over the cords Rack or Wall Mounting Using the optional bracket kit 5183 7210 two Switch 408 units can be mounted together in any EIA standard 19 inch telco rack or in an equipment cabinet such as a server cabinet The switch brackets can a...

Page 23: ...e tab on the plug clicks into place When power is on for the switchandfortheconnected device the Link Act LED for the port should light to confirm a powered on device for example an end node is at the other end of the cable If the Link LED does not go onwhenthenetworkcableis connected to the port see Diagnosing With the LEDs in chapter 3 Trouble shooting To disconnect Press the small tab on the pl...

Page 24: ... desktop switch to which end nodes printers and other peripherals and servers are directly connected as shown in the above illustration Note Make sure the network into which you are installing the Switch 408 has a valid topology there should be no loops in the data paths connected to the switch and all twisted pair connections should be no more than 100 meters twisted pair straight throughor cross...

Page 25: ...ith PCs printers and local servers attached are both connected to a Switch 408 The devices attached to the two hubs can now communicate with each other through the switch They can also all communicate with the server that is connected to the switch Make sure connections from servers to the Switch 408 are at 100 Mbps to minimize network congestion to the servers Ethernet Hubs Server twisted pair ca...

Page 26: ...he connections to the end nodes and the servers can be through straight through cables You can also use crossover cables for these connections In either case the Switch 408 automat ically adjusts to the type of cable used and to the type of device at the other end of the connection The 100 Mbps connection to the server and any other 100 Mbps connections must be through category 5 or better cable ...

Page 27: ...figura tion The Switch 408 ports are set to auto negotiate the link characteristics That is when connecting to attached devices the switch willoperate in one oftwo waystodetermine the link speed and the communication mode half duplex or full duplex if the connected device is also set to auto negotiate the switch will automatically negotiate both link speed and communication mode iftheconnecteddevi...

Page 28: ...ndard cables Non standard and miswired cables may cause numerous network collisions and other network problems and can seriously impair network performance Use a new correctly wired cable or compare your cable to the cable in appendix B Cables and Connectors for pinouts and correct cable wiring A category 5 cable tester is a recommended tool for every 100Base T network installation Improper Networ...

Page 29: ...t your network performance Diagnosing With the LEDs Table 3 1 shows LED patterns on the switch that indicate problem conditions 1 Check in the table for the LED pattern that you see on your switch 2 Refer to the corresponding diagnostic tip on the next few pages Table 3 1 LED Error Indicators LED Pattern Indicating Problems Diagnostic Tips Power Fault Port Link Off with power cord plugged in On Pr...

Page 30: ...o get assistance See the Customer Support Warranty booklet for more information A switch hardware failure was detectedduring self test Try power cycling the switch If the fault indication reoccurs the switch may have failed Call your ProCurve authorized LAN dealer or use the electronic support services from ProCurve to get assistance See the Customer Support Warranty card for more information The ...

Page 31: ...f after approximately 3 seconds If this LED stays on longer than 5 seconds an error condition has been detected on the switch See Diagnosing With the LEDs on page 3 3 for information on interpreting the LED patterns Testing Twisted Pair Cabling If you think the cable should work but still isn t working it may not be compatible with the IEEE 802 3 Type 10Base T or 100Base TX standards The twisted p...

Page 32: ...rrectly See your LAN adapter documentation for more information on running a link test or Ping test ProCurve Customer Support Services If you are still having trouble with your switch ProCurve offers support24hoursa day sevendaysaweek through theuseofa number of automated electronic services See the Customer Support Warranty booklet that came with your switch for information on how to use these se...

Page 33: ... 4 0 cm 1 6 in Weight 0 72 kg 1 60 lbs DC voltage 12 13 volts Maximum current 1 0 0 8 A Operating Non Operating Temperature 0 C to 40 C 32 F to 104 F 40 C to 70 C 40 F to 158 F Relative humidity non condensing 10 to 90 at 40 C 104 F 10 to 90 at 65 C 149 F Maximum altitude 3 0 km 9 843 ft 4 6 km 15 000 ft ...

Page 34: ... 100Base TX and IEEE 802 3 Type 10Base T stan dards All ports include the HP Auto MDIX feature which allows the use of either straight through or crossover cables for any twisted pair connection Safety The Switch 408 complies with these safety standards EN60950 IEC 60950 CSA NRTL CSA 22 2 No 60950 UL 60950 ...

Page 35: ...her network device that has RJ 45 connectors These additional rules apply to the twisted pair cabling All twisted pair wires used must be twisted through the entire length of the cable The wiring sequence must conform to the ANSI TIA EIA 568 B cable specification See Twisted Pair Cable Pin Assignments later in this appendix for a listing of the signals used on each pin Note Incorrectly wired cabli...

Page 36: ...tegory 5 UTP or STP cable only as supported by the IEEE 802 3u Type 100Base TX standard Straight Through Twisted Pair Cable Note Pins 1 and 2 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B Pins 4 5 7 and 8 are not used in this application although they may be wired in the cable...

Page 37: ...t be wired as a twisted pair to pins 3 and 6 on connector B Pins 3 and 6 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B Pins 4 5 7 and 8 are not used in this application although they may be wired in the cable Crossover Cable white orange orange white white green green white Connector A Connector B ...

Page 38: ...Pair Crossover Cable Switch End Computer Transceiver or Other MDI Port End Signal Pins Pins Signal receive receive transmit transmit 1 2 3 6 1 2 3 6 transmit transmit receive receive Switch End Hub or Switch Port or Other MDI X Port End Signal Pins Pins Signal receive receive transmit transmit 1 2 3 6 6 3 2 1 transmit transmit receive receive ...

Page 39: ...s been restored For LAN cable grounding If your LAN covers an area served by more than one power distribution system be sure their safety grounds are securely interconnected Documentationreference symbol Ifthe productismarkedwith this symbol refer to the product documentation to get more information about the product WARNING A WARNING in the manual denotes a hazard that can cause injury or death C...

Page 40: ... the electrical utilities power grid Handle exposed metal com ponents of the network with caution Servicing There are no user serviceable parts inside these products Any servicing adjustment maintenance orrepairmustbeperformedonly by service trained personnel These products do not have a power switch they are powered on when the adapter s power cord is plugged in ...

Page 41: ...ons transitoires dangereuses telles que la foudre ou des perturbations dans le réseau d alimentation public Manipulez les composants métalliques du réseau avec précautions Aucune pièce contenue à l intérieur de ce produit ne peut être réparée par l utilisateur Tout dépannage réglage entretien ou réparation devra être confié exclusivement à un personnel qualifié Cet appareilne comporte pas de commu...

Page 42: ...en beispielsweise durch Blitz oder Störungen in dem Starkstromnetz des Elektrizitätswerks Bei der Handhabung exponierter Metallbestandteile des Netzwerkes Vor sicht walten lassen Dieses Gerät enthält innen keine durch den Benutzer zu wartenden Teile Wartungs Anpassungs Instandhaltungs oderReparaturarbeitendürfennur von geschultem Bedienungspersonal durchgeführt werden Dieses Gerät hat keinen Netzs...

Page 43: ...N possono occasionalmente andare soggetti a pericolose tensioni transitorie ad esempio provocate da lampi o disturbi nella griglia d alimentazione della società elettrica siate cauti nel toccare parti esposte in metallo della rete Nessun componente di questo prodotto può essere riparato dall utente Qual siasi lavoro di riparazione messa a punto manutenzione o assistenza va effettuato esclusivament...

Page 44: ...e que los cables de la LAN se vean sometidos de vez en cuando a voltajes momentáneos que entrañen peligro rayos o alteraciones en la red de energía eléctrica Manejar con precaución los componentes de metal de la LAN que estén al descubierto Este aparato no contiene pieza alguna susceptible de reparación por parte delusuario Todaslas reparaciones ajustes oserviciodemantenimiento debe realizarlos so...

Page 45: ...C 7 Safety and Regulatory Statements Safety Information Japan Safety Information Japan WAR NIN G ...

Page 46: ...C 8 Safety and Regulatory Statements Safety Information China Safety Information China ...

Page 47: ...rated in a commercial envi ronment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communica tions Operation of this equipment in a residential area may cause interference in which case the user will be required to correct the interference at his own expense Canada This prod...

Page 48: ...C 10 Safety and Regulatory Statements EMC Regulatory Statements Japan VCCI Class A Korea Taiwan ...

Page 49: ...0950 1 2001 IEC 60950 1 2001 EMC EN 55022 1998 A1 2000 A2 2003 CISPR 22 1997 Class A A1 2000 A2 2002 EN 55024 1998 A1 2001 A2 2003 EN 61000 3 2 2000 Harmonics EN 61000 3 3 1995 A1 2001 Flicker Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE marking accordingly Tested with Hewlet...

Page 50: ...㓚 㒓 0 0 0 0 0 0 0 0 0 0 0 0 亢 亢 Ⲭ X 0 0 0 0 0 䗖䜡 ᅝ㺙ᬃᶊ ᅗ䰘 0 0 0 0 0 0 ӊ 0 0 0 0 0 0 CF व 2 㸼 ℸ䚼ӊՓ ⱘ᠔ ৠ ᴤ Ёℸ ᆇ 䋼ⱘ 䞣ഛԢѢ SJ T11363 2006 㾘ᅮⱘ䰤ࠊ㽕 DŽ X 㸼 ℸ䚼ӊՓ ⱘ㟇ᇥϔ ৠ ᴤ Ёˈℸ ᆇ 䋼ⱘ 䞣催Ѣ SJ T11363 2006 㾘ᅮⱘ䰤ࠊ㽕 DŽ ᠔ᓩ ⱘ ֱՓ ᳳ䰤 䆄ḍ ѻકⱘℷᐌ Փ ᴵӊ བ ᑺ ᑺ ᅮDŽ 䰸䴲 ᯢˈℸ ᄤֵᙃѻક ᶧ ࠊ 䆄䗖 Ѣ᠔ ProCurve Networking by HP ѻકDŽ This information is required by the People s Republic of China as per their legislation titled Management Methods for...

Page 51: ...D 1 D Recycle Statements Waste Electrical and Electronic Equipment WEEE Statements ...

Page 52: ...uman health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus See tootel või selle pakendil olev sümbol näitab et kõnealust toodet ei tohi koos teiste majapidami...

Page 53: ...région les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit Entsorgung von Altgeräten aus privaten Haushalten in der EU Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass das Produkt nicht über den normalen Hausmüll entsorgt werden darf Benutzer sind verpflichtet die Altgeräte an einer Rücknahmestelle für Elektro und Elektronik A...

Page 54: ...Ħjtés pontos helyérĘl bĘvebb tájékoztatást a lakhelye szerint illetékes önkormányzattól az illetékes szemételtakarító vállalattól illetve a terméket elárusító helyen kaphat Nolietotu iekƗrtu iznƯcinƗšanas noteikumi lietotƗjiem Eiropas SavienƯbas privƗtajƗs mƗjsaimniecƯbƗs ŠƗds simbols uz izstrƗdƗjuma vai uz tƗ iesaiƼojuma norƗda ka šo izstrƗdƗjumu nedrƯkst izmest kopƗ ar citiem sadzƯves atkritumie...

Page 55: ...m esse tipo de material entre em contato com o escritório da HP em sua cidade com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido Pozbywanie siĊ zuĪytego sprzĊtu przez uĪytkowników w prywatnych gospodarstwach domowych w Unii Europejskiej Ten symbol na produkcie lub jego opakowaniu oznacza Īe produktu nie wolno wyrzucaü do zwykáych pojemników na Ğmieci Obowiązkiem uĪytkowni...

Page 56: ...balaži pomeni da izdelka ne smete odvreþi med gospodinjske odpadke Nasprotno odsluženo opremo morate predati na zbirališþe pooblašþeno za recikliranje odslužene elektriþne in elektronske opreme Loþeno zbiranje in recikliranje odslužene opreme prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv naþin Za podrobnejše informacije o tem kam lahko od...

Page 57: ...hooting tips 3 1 C cabinet mounting the switch in 2 8 cable diagrams crossover cable B 3 straight through cable B 2 cables 100Base TX connections 2 5 10Base T connections 2 5 connecting cables to switch ports 2 9 effects of non standard cables 3 2 twisted pair connector pin outs B 1 cables twisted pair category 3 4 5 B 2 crossover cable diagram B 3 crossover cable pin out B 4 pin outs B 4 straight...

Page 58: ...ng 3 1 H horizontal surface mounting switch on 2 8 HP Auto MDIX affect on cable usage 2 5 2 12 A 2 B 1 description 1 5 I included parts 2 1 installation connecting the switch to a power source 2 9 mounting switch in rack or cabinet 2 8 mounting switch on a wall 2 8 on a horizontal surface 2 8 precautions 2 3 summary 2 2 L LEDs 100 description 1 3 behavior during self test 2 7 checking during troub...

Page 59: ... 1 pin outs twisted pair cables B 1 port LEDs 100 1 3 FDx 1 3 Link Act 1 3 ports 10 100Base TX location on switch 1 2 network connections 2 9 power connector 1 4 Power LED 1 3 behavior during self test 2 7 power source connecting the switch to 2 9 precautions mounting the switch 2 3 power requirements 2 3 R rack mounting precautions 2 3 mounting the switch in 2 8 regulatory statements C 9 resettin...

Page 60: ... checking the LEDs 3 5 diagnostic tests 3 5 end to end communications 3 6 switch operation 3 5 twisted pair cabling 3 5 tips for troubleshooting 3 1 topologies effects of improper topology 3 2 samples of 2 10 troubleshooting basic tips 3 1 checking the LEDs 3 5 common network problems 3 1 diagnostic tests 3 5 effects of improper topology 3 2 effects of non standard cables 3 2 fixed full duplex con...

Page 61: ... This page is intentionally unused ...

Page 62: ... This page is intentionally unused ...

Page 63: ......

Page 64: ...ght 2001 2005 2006 2007 Hewlett Packard Development Company L P All rights reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Printed in Taiwan February 2007 Manual Part Number 5991 6250 5991 6250 ...

Reviews: