manualshive.com logo in svg
background image

HP B-series Network Advisor Enterprise,
Professional Plus, and Professional 11.1.5
Release Notes

HP Part Number: 5697-2464
Published: January 2013
Edition: 1

Содержание B-series Network Advisor Professional 11.1.5

Страница 1: ...HP B series Network Advisor Enterprise Professional Plus and Professional 1 1 1 5 Release Notes HP Part Number 5697 2464 Published January 2013 Edition 1 ...

Страница 2: ... Copyright 201 1 2013 Hewlett Packard Development Company L P ...

Страница 3: ...d the HP SN8000B 4 Slot SAN Director Switch Both director switches are highly available modular and scalable platforms New 16 Gbps Core Blades for the 16 Gbps director switches enabling twice the slot bandwidth available in previous generation directors HP SN8000B 16Gb 32 port Fibre Channel Blade and HP SN8000B 16Gb 48 port Fibre Channel Blade New software features SAN Management Feature Enhanceme...

Страница 4: ...ility to include or exclude performance and historical events from the database while capturing server support save from SMC SAN size check A popup message is displayed when the discovered port switch AG count exceeds the SAN size selected small medium large MD5 checksum validation MD5 checksum validation is done before importing firmware files into the repository Migration and upgrades DCFM 10 4 ...

Страница 5: ... SAN Switch Brocade Encryption Switch 7 HP StorageWorks 4 256 SAN Director Brocade 48000 with HP StorageWorks 4 256 SAN Director with 16 Port 4Gb Blade FC4 16 2 HP StorageWorks 4 256 SAN Director Brocade 48000 with HP StorageWorks 4 256 SAN Director 32 Port 4Gb Blade FC4 32 2 HP StorageWorks 4 256 SAN Director Brocade 48000 with HP StorageWorks 4 256 SAN Director 48 Port 4Gb Blade FC4 48 2 HP Stor...

Страница 6: ... StorageWorks 4 256 SAN Director 48 Port 4Gb Blade FC10 6 HP StorageWorks DC04 SAN Director Switch8 with HP StorageWorks DC Switch Encryption FC Blade FS8 18 HP StorageWorks DC04 SAN Director Switch10 with HP DC SAN Director 10 24 FCoE Blade FCoe10 24 HP StorageWorks DC04 SAN Director Switch10 with HP DC SAN Director Multiprotocol Extension Blade FX8 24 HP StorageWorks DC04 SAN Director Switch1 1 ...

Страница 7: ... Fabric OS 5 2 1b or later 4 Requires Fabric OS 5 3 0 or later 5 Requires Fabric OS 6 1 0a or later 6 Requires Fabric OS 6 0 0b or later 7 Requires Fabric OS 6 1 1_enc or later 8 Requires Fabric OS 6 2 0 or later 9 Requires Fabric OS 6 1 2_CEE or later 10 Requires Fabric OS 6 3 x or later 1 1 Requires Fabric OS 6 4 0 or later 12 Requires Fabric OS 7 0 0a or later 13 Requires Fabric OS 7 0 1 or lat...

Страница 8: ...s M EOS Fabric OS Mixed M EOS Fabric OS Mixed Fabric OS Type of fabric supported 9 000 Fabric OS 5 000 M EOS Mixed 2 560 1 000 Number of ports Yes Yes Yes 4 Gb and 8 Gb Switches Yes Yes Yes DC SAN Director 10 24 FCoE Blade 2408 FCoE Converged Network Switch Yes Yes Yes 1606 Extension SAN Switch Yes Yes Yes 4 256 SAN Director Yes Yes Yes DC04 SAN Director Switch Yes Yes Yes SN8000B 4 Slot SAN Direc...

Страница 9: ...he Windows folder 3 Execute install exe 4 Follow the screen instructions to complete the installation Installing Network Advisor on Linux Server 1 Download and extract the tar gz archive 2 Navigate to the Linux folder 3 Execute Install bin from the File Manager window 4 Follow the screen instructions to complete the installation Launching the Network Advisor Client To launch the Network Advisor Cl...

Страница 10: ...t from the same switch or blade and running a diagnosis on them simultaneously might result in failure HP recommends that you choose only one port at a time from any given switch or blade for running the diagnostic port test If a fabric has a large zone database or effective zone configuration approximately 1 MB zoning report generation may fail If IPv6 is enabled on the Fabric OS switch along wit...

Страница 11: ...ox the logical switch displays under undiscovered Logical Switch in the existing Logical Switches Panel You must rediscover the newly created logical switch fabric Destination columns are blank for HP StorageWorks Encryption SAN Switch in top talkers dialog When the Top Talkers dialog box is launched for the HP StorageWorks Encryption SAN Switch the columns Destination Destination port and Destina...

Страница 12: ...solved in Network Advisor 1 1 1 1 but users will see the same issue in the migrated server from Network Advisor 1 1 1 0 to 1 1 1 2 As a workaround remove boot image files having version numbers greater than or equal to 3 0 from the repository and re execute the import Port disable enable operation may fail The Port disable enable operation on physical TE Ports may fail in the following scenarios D...

Страница 13: ...ta value1 1000 1000 Polling interval2 1000 PortTX variable from the return html file HTTP EE Monitors RX TX Delta value1 1000 1000 Polling interval2 1000 N A HCM API HBA CNA TX RX Delta value1 1000 1000 Polling interval2 1000 N A HCM API HBA CNA RX TX Delta value1 1000 1000 1000 1 3 6 1 2 1 2 2 1 1 1 1 3 6 1 2 1 31 1 1 1 2 1 3 6 1 2 1 31 1 1 1 3 SNMP TE TX RX Delta value1 1000 1000 1000 1 3 6 1 2 ...

Страница 14: ...the return html file HTTP EE Monitors CRC Errors Installation on Network Mounted Drives is not supported Installation onto a windows network mounted drive is not supported but installation if attempted is allowed and DB fails to start Client disconnects Under heavy server load or degraded network links there is a potential for the Network Advisor client to disconnect from the server The workaround...

Страница 15: ...out the location and capabilities of the WBEM Server to which it wants to send its requests In such environments you do not need to start the SLP component of the Management application SMI Agent However in a dynamically changing enterprise network environment many WBEM clients might choose to use SLP discovery to find the location and capabilities of other WBEM Servers In such environments start ...

Страница 16: ...ss Port is the IP address and port number that display when you use the slptool findsrvs service wbem command slptool findattrs service wbem https IP_Address Port Use this command to verify that the Management application SMI Agent SLP service is properly advertising its WBEM SLP template over the HTTPS protocol Example input slptool findattrs service wbem https 10 0 1 2 5989 NOTE IP_Address Port ...

Страница 17: ...P register Management_Application cimom cfg slp reg Statically register an application that does not dynamically register with SLP using SLPAPIs by modifying this file For more information about these files read the comments contained in them or see http www openslp org doc html UsersGuide index html Verifying SLP service installation and operation on Windows systems 1 Launch the Server Management...

Страница 18: ...entation Updates For the most recent Network Advisor documentation visit the following HP website http h18006 www1 hp com products storageworks dc_fabricmgr index html Under Support select HP Support Documents and then select Manuals HP Network Advisor 1 1 1 0 fixes Table 7 page 18 lists the closed defects for this release Table 7 HP Network Advisor 1 1 1 0 closed defects Solution Closed fixes sum...

Страница 19: ...he FCIP Tunnel dialog box Fixed in HP Network Advisor 1 1 1 0 Fixed in HP Network Advisor 1 1 1 0 In the Client the Logical Switch Sequence Number is displayed incorrectly in the Switch Properties Dialog Fixed in HP Network Advisor 1 1 1 0 In Port Fencing Switch level Alert was missing when a port is fenced for Link reset violation type Workaround prior to upgrade Change commit rates on both the l...

Страница 20: ...here is a Java SE for Business Denial of Service Vulnerability Fixed in HP Network Advisor 1 1 1 0 Customers get the wrong property value for Brocade_Product Vendor property Fixed in HP Network Advisor 1 1 1 0 Firmware Management message states that Coordinated Hot Code Load is not supported on switches Fixed in HP Network Advisor 1 1 1 0 In Rekey Sessions dialog same re key session number is disp...

Страница 21: ... LSAN zoning dialog the Alias name is not shown in the WWN fabric assigned potential member panel Fixed in HP Network Advisor 1 1 1 1 Ping or traceroute fail when IP interfaces and crossport interfaces are defined on XGE ports Fixed in HP Network Advisor 1 1 1 1 A duplicate entry is displayed for each device in the Configuration Repository after migrating from Network Advisor 1 1 1 0 to Network Ad...

Страница 22: ...osed fixes summary Fixed in HP Network Advisor 1 1 1 3 Only 80 out of 1000 Active Directory security groups are presented in Network Advisor Active Directory security groups are not fully shown in the application Fixed in HP Network Advisor 1 1 1 3 SNMP traps sent to the server are not being processed Fixed in HP Network Advisor 1 1 1 3 On Brocade HBAs updates in Host Discovery deleted and newly d...

Страница 23: ...HP Network Advisor 1 1 1 5 fixes Table 12 page 23 lists the closed defects for this release Table 12 HP Network Advisor 1 1 1 5 closed defects Solution Closed fixes summary Workaround prior to upgrade The value of the Count column present in the Custom The event count displayed in the dashboard does not match the count in the event report Event Report should be added up to match the total Dashboar...

Страница 24: ...work Advisor 1 1 1 5 Users are unable to add some storage devices shown under the storage group topology view to storage port mapping Fixed in Network Advisor 1 1 1 5 It takes a long time to log in to the Network Advisor client and switch between views Fixed in Network Advisor 1 1 1 5 In the zoning dialog the Host group cannot be expanded by clicking on the icon after the tree is sorted Fixed in N...

Отзывы: