HOSHIZAKI

MODULAR CRESCENT CUBER

INSTRUCTION MANUAL

FEB. 21, 2001

MODELS

KML-450MAH
KML-450MWH

REVISED: SEPT. 24, 2001

TM

Summary of Contents for KML-450MAH

Page 1: ...ISSUED HOSHIZAKI MODULAR CRESCENT CUBER INSTRUCTION MANUAL FEB 21 2001 MODELS KML 450MAH KML 450MWH REVISED SEPT 24 2001 TM...

Page 2: ...service or maintain this icemaker No installation service or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual Likewise the owner manager should not pro...

Page 3: ...ECIFICATIONS 4 1 NAMEPLATE RATING 4 a KML 450MAH Air cooled 4 b KML 450MWH Water cooled 5 2 DIMENSIONS CONNECTIONS 6 a KML 450MAH 6 b KML 450MWH 7 II INSTALLATION AND OPERATING INSTRUCTIONS 8 1 CHECKS...

Page 4: ...te is located on the rear panel of the icemaker it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment Therefore the necessary electrical and r...

Page 5: ...the rear panel of the icemaker it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment Therefore the necessary electrical and refrigeration inf...

Page 6: ...6 2 DIMENSIONS CONNECTIONS a KML 450MAH Unit inches mm...

Page 7: ...7 b KML 450MWH Unit inches mm...

Page 8: ...switch actuator arm and paddle in place so that the paddle swings down freely c Replace the Bin Control Cover 4 Remove the protective plastic film from the panels If the icemaker is exposed to the su...

Page 9: ...ing ambient temperature should be within 45 F to 100 F Normal operating water temperature should be within 45 F to 90 F Operation of the icemaker for extended periods outside of these normal temperatu...

Page 10: ...connection must be made in accordance with the instructions on the WARNING tag provided with the pig tail leads in the Junction Box 2 This icemaker requires a ground that meets the national and local...

Page 11: ...rt Code 311166A01 Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG If the pressure exceeds 113 PSIG the use of a pressure reducing valve is required Drain outlet for icem...

Page 12: ...12 Fig 4 KML 450MWH KML 450MAH...

Page 13: ...installed in the icemaker 7 Are the Water Supply Line Shut off Valve and Drain Valve installed Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG Note...

Page 14: ...Control Box to the ICE position 4 Replace the Front Panel in its correct position 5 Turn on the power supply and allow the Water Tank to fill with water and the icemaker to operate for a total of 10 m...

Page 15: ...Replace the Bin Control Cover 9 Move the Control Switch to the Service position Then move the Service Switch to the Drain position 10 Replace the Front Panel 11 Turn on the power supply for 2 minutes...

Page 16: ...water cooled model only first remove the water from the water cooled condenser 1 Turn off the power supply 2 Remove the Front Panel 3 Move the Control Switch on the Control Box to the OFF position 4...

Page 17: ...ity 6 Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve 7 Move the Control Switch to the ICE position 8 Replace Front Panel and turn on the power supply 9 Blow the p...

Page 18: ...ded cleaner Hoshizaki Scale Away or LIME A WAY Economics Laboratory Inc with 2 gal of water 2 Remove all ice from the Evaporator and the Storage Bin Note To remove cubes on the Evaporator turn off the...

Page 19: ...t Panel in its correct position 20 Turn on the power supply to fill the Water Tank with water 21 Turn off the power supply after 3 minutes 22 Remove the Front Panel 23 Move the Control Switch to the S...

Page 20: ...Insulation Panel and the Front Panel in their correct position 6 Turn on the power supply and start the sanitizing process 7 Turn off the power supply after 15 minutes 8 Remove the Front Panel 9 Move...

Page 21: ...n the bin Keep the scoop clean Clean it by using a neutral cleaner and rinse thoroughly Clean the bin liner by using a neutral cleaner Rinse thoroughly after cleaning 3 Air Filter Air cooled model onl...

Page 22: ...22 91A1BE10B HOSHIZAKI HOSHIZAKI AMERICA INC 618 HIGHWAY 74 SOUTH PEACHTREE CITY GA 30269 U S A PHONE 770 487 2331...