background image

m

 WARNING

PERSONAL INJURY

DO NOT USE these products as safety or emergency stop 
devices or in any other application where failure of the product 
could result in personal injury.

Failure to comply with these instructions could result in 
death or serious injury.

Installation Instructions for the

Wireless Hazardous Area Limit Switches, WBX Series

Issue 3

50096377

m

 WARNING

Honeywell does not recommend using devices for critical 
control applications where there is, or may be, a single point 
of failure or where single points of failure may result in an 
unsafe condition. It is up to the end-user to weigh the risks 
and benefits to determine if the products are appropriate for 
the application based on security, safety and performance.  
Additionally, it is up to the end-user to ensure that the control 
strategy results in a safe operating condition if any crucial 
segment of the control solution fails. Honeywell customers 
assume full responsibility for learning and meeting the 
required Declaration of Conformity, Regulations, Guidelines, 
etc. for each country in their distribution market.

m

 WARNING

RF EXPOSURE

To satisfy FCC RF exposure requirements for mobile 
transmitting devices, a separation distance of 20 cm or more 
should be maintained between the antenna of this device 
and persons during device operation To ensure compliance, 
operation at closer than this distance is not recommended. 
The antenna used for this transmission must not be co-
located in conjunction with any other antenna or transmitter.

Failure to comply with these instructions could result in 
death or serious injury.

m

 WARNING

The WBX  must be installed in accordance with the 
requirements specified in this document in order to 
comply with the specific Country Communication Agency 
requirements (i.e., FCC, IC, ETSI, ACMA, etc.). See Section 6.2 
as this requires choosing the correct Country Use Code and 
thus allowable antenna and/or cable usage.

m

 WARNING

RISK OF DEATH OR SERIOUS INJURY FROM 
EXPLOSION OR FIRE

Connection and disconnection of the antennas should only 
be performed in a non-hazardous area and with 

no battery 

power

 applied to the WBX. This is due to the risk of possibly 

damaging the internal WBX electronics and/or igniting the  
surrounding hazardous atmosphere.

Failure to comply with these instructions could result in 
death or serious injury.

m

 WARNING

POTENTIAL ELECTROSTATIC CHARGING 
HAZARD

When the WBX Series is installed in potentially hazardous 
locations, care should be taken not to electrostatically 
charge the surface of the antenna shroud by rubbing the 
surface with a cloth, or cleaning the surface with a solvent.  If 
electrostatically charged, discharge of the antenna shroud to a 
person or a tool could possibly ignite a surrounding hazardous 
atmosphere.

m

 WARNING

RISK OF DEATH OR SERIOUS INJURY FROM 
EXPLOSION OR FIRE

Connection and disconnection of the batteries should only be 
performed in a non-hazardous area. The batteries used in this 
device may present a risk of fire or chemical burn if mistreated. 
Do not recharge, disassemble, heat above 100 °C [212 °F], or 
incinerate.

Failure to comply with these instructions could result in 
death or serious injury.

m

 WARNING

POTENTIAL IMPACT HAZARD

Care should be taken during installation of the WBX switch to 
not apply an impact force to the device. (i.e. dropping the WBX 
on a hard surface, impact with a hammer/wrench, etc.). 

m

 WARNING

Device cannot be used without metal “S” shaped clamp and 
screw securely fastened to switch.

m

 WARNING

Enclosure contains aluminum. Care must be taken to avoid 
ignition hazard due to impact.

Summary of Contents for WBX Series

Page 1: ...his document in order to comply with the specific Country Communication Agency requirements i e FCC IC ETSI ACMA etc See Section 6 2 as this requires choosing the correct Country Use Code and thus allowable antenna and or cable usage m WARNING RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE Connection and disconnection of the antennas should only be performed in a non hazardous area and wit...

Page 2: ...he actuator po sition of the WBX via a visual indicator audible indicator and or electronic output The WBX supports no electrical signal inputs and is powered by a replaceable battery 1 3 Abbreviations and Definitions Table 1 Table of Abbreviations and Definitions ACMA Australian Communications and Media Authority cpm Cycles Per Minute dB Decibel dBi Decibel Isotropic dBm Decibel above or below 1 ...

Page 3: ...al electrical code requirements Earth Ground Functional earth connection NOTE This connection shall be bonded to Protective Earth at the source of supply in accordance with national and local electrical code requirements Chassis Ground Identifies a connection to the chassis or frame of the equipment shall be bonded to Protective Earth at the source of supply in accordance with national and local e...

Page 4: ...an TL 5903 S or Bi Power ER14505H batteries ATTENTION IEC 60079 0 2007 10 and IEC 60079 11 2006 were applied to the integral component fuse Part No 0259 125TX913 manufactured by Littelfuse There are no significant safety related changes between these editions and the later editions of the standards noted under the Standards section of this document 2 2 Electrical Specifications Table 4 Electrical ...

Page 5: ...th electrical power Once they are no longer contacting electrical power administer CPR if certified and make sure emergency medical aid has been requested m WARNING TO AVOID FALLING USE SAFE PROCEDURES WHEN WORKING AT HEIGHTS ABOVE GROUND Select equipment locations that will allow safe simple equipment installation Don t work alone A friend or co worker can save a life if an accident happens Use a...

Page 6: ...II Div 1 Groups E F G Class I Zone 1 AEx ia IIC T4 Ga Class I Zone 1 Ex ia IIC T4 Ga Class II Zone 21 AEx ia IIIC T135 C Da Class I Zone 0 AEx ia IIC T4 Ga Class I Zone 0 Ex ia IIC T4 Ga Class II Zone 20 AEx ia IIIC T135 C Da Tambient 40 C to 70 C Zone 1 Ex ia IIC T4 Ga Zone 21 Ex ia IIIC T135 C Da Zone 0 Ex ia IIC T4 Ga Zone 20 Ex ia IIIC T135 C Da Zone 1 Ex ia IIC T4 Ga Zone 21 Ex ia IIIC T135 C...

Page 7: ...lass I II Div 1 Groups A B C D E F G Voc 5 0 V Isc 757 mA Po 0 946 W Ca 23 48 µF La 4 487 µH NOTES 1 Only lightning surge arrestors determined to be simple apparatus may be installed 2 Refer to Tables 10 and 11 in following page that cap tures the approved antenna to be used with the WBX product as remote connection 6 REMOTE ANTENNAS 6 1 Intrinsically Safe Device Entity Parameters for Remote Anten...

Page 8: ... uses N type jack 2 Industry Canada Compliance Statement This device has been designed to operate with the antenna types listed in this docu ment and having a maximum gain of 9 dBi Antenna types not included in this list or having a gain greater than 9 dBi are strictly prohibited for use with this device The required antenna impedance is 50 Ohm Table 18 Antenna Options for All Other Approved Count...

Page 9: ... battery do not snag the battery terminal on the clip or the battery may be damaged Do not apply ex cessive force Do not drop Dropping the battery may cause damage If a battery is dropped do not install the dropped battery into the WBX Dispose of dropped battery promptly per local regulations or per the battery manufacturer s rec ommendations Failure to comply with these instructions could result ...

Page 10: ...attempt to bend the battery s hold down tabs forward Insert the battery negative end first at an angle and against the end of the tab Push down the battery into position gently Ensure the batteries are properly seated and making contact IMPORTANT If the ORANGE LED does not blink it is recommended to remove one of the batteries and re insert back again 5 Repeat steps 3 and 4 for the other battery 6...

Page 11: ...ctions for the Wireless Hazardous Area Limit Switches WBX Series ISSUE 3 50096377 8 DECLARATION OF CONFORMITY 8 1 European CE Declaration of Conformity DoC 8 1 1 European Declaration of Conformity Statements Figure 5 European Declaration of Conformity DoC ...

Page 12: ... 5 mm 5 73 in 15 9 mm 0 63 in 145 6 mm 5 73 in Operating Head Code A Straight Antenna Operating Head Code A 90 Antenna Total Travel T T Overtravel O T Pretravel P T R T R T Release Travel R T 218 3 mm 8 6 in 2X Ø5 16 mm 0 203 in mounting hole MECHANICAL OPERATING SPECIFICATIONS for Side Rotary Actuators Table 12 Operating Specifications Mechanical Characteristic Operating Head Code A Momentary Pre...

Page 13: ...94 mm 2 28 in operating point 21 46 mm 0 85 in 145 5 mm 5 73 in 15 9 mm 0 63 in 145 6 mm 5 73 in Operating Head Code C 90 Antenna Differential Travel Over Travel Pre Travel Full Travel Operating Point Release Point MECHANICAL OPERATING SPECIFICATIONS for Pin Plunger Actuators Table 13 Operating Specifications Mechanical Characteristic Operating Head Code C Top Plunger Plain Pretravel 1 78 mm 0 07 ...

Page 14: ...d Code J Straight Antenna Operating Head Code J 90 Antenna Ø 76 2 mm 3 00 in 85 73 mm 3 38 in 38 99 mm 1 54 in 155 5 mm 6 12 in Ø 6 35 mm 0 25 in 19 81 mm 0 78 in 21 46 mm 0 85 in 145 5 mm 5 73 in 15 9 mm 0 63 in Pretravel 25 4 mm 1 0 in MECHANICAL OPERATING SPECIFICATIONS for Wobble Stick Actuators Table 14 Operating Specifications Mechanical Characteristic Operating Head Code J Wobble Stick Pret...

Page 15: ...ucciones de instalación y otros documen tos se encuentran disponibles en el sitio de internet de Honey well en múltiples idiomas Para acceder 1 Vaya a sensing honeywell com hazardousareaswitches 2 Seleccione las instrucciones del producto en la sección de in struccions de instalación Les instructions d installation et d autres documents sont dis ponibles dans plusieurs langues sur le site Web d Ho...

Page 16: ...sonally through our literature and the Honeywell web site it is buyer s sole responsibility to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of this writing However Honeywell assumes no responsibility for its use SALES AND SERVICE Honeywell serves its customers through a worl...

Reviews: