background image

PRODUCT DATA

Copyright © 1998 Honeywell Inc.   •   All Rights Reserved

APPLICATION

T8205B,C and TS8205B,C Electronic Pool and Spa Control
Systems are used in pool, spa, and hot tub applications to
control water temperature. T8205B,C and TS8205B,C Control
System components include a T8205A,H or TS8205A Control
Module and Q8205A-C Setpoint Panel. Sensor Assembly is
purchased separately. The T8205A and TS8205A Control
Modules and Q8205A-C Setpoint Panels can be purchased
separately. The T8205H Control Module is for use with heat
pump systems only. Q8205A-C Setpoint Panels can be used
for remote applications.

T8205B,C, TS8205B,C  Electronic Pool,

Spa Control Systems; T8205A,H, TS8205A Control

Modules; Q8205A-C Setpoint Panels and Sensor Assembly

FEATURES

T8205 requires 24 Vac power supply; TS8205 is used in
a 750 mV self-generating system.

T8205B,C and TS8205B,C include an electronic control
module and setpoint panel packaged together to
simplify installation. The sensor must be ordered
separately.

T8205A and TS8205A Control Modules are used with a
sensor and Q8205A-C Setpoint Panel.

T8205H Control Module is for use with heat pump
systems only and has 1/4 in. quick connect terminals.

Module controls within 1.5

°

F (0.8

°

C) at setpoint of

106

°

F (41

°

C).

Models available for single control or dual control of
combination pool and spa.

Isolated relay contacts in electronic control modules
operate gas control or ignition module.

Male quick-connect wiring terminals provided on
electronic control modules.

Sensor with 3/16 in. female quick connects on 42 in.,
48 in., 50 in., or 96 in. leadwires can be directly
immersed or mounted in well.

Setpoint panel can be remotely mounted.

Plastic potentiometers and selector switches provide
increased protection from humidity and chlorine.

Combination of 1/4 in. and 3/16 in. quick connect
terminals provide ANSI miswiring compliance, except
T8205H Control Module.

Contents

Application ........................................................................... 1
Features .............................................................................. 1
Specifications ......................................................................

2

Ordering Information ...........................................................

2

Installation ........................................................................... 5
Settings ...............................................................................

7

Checkout .............................................................................

7

Operation ............................................................................

8

Troubleshooting ...................................................................

8

T8205C

T8205A

TS8205B

Q8205A

68-0177-1

Summary of Contents for Q8205A

Page 1: ...o simplify installation The sensor must be ordered separately T8205A and TS8205A Control Modules are used with a sensor and Q8205A C Setpoint Panel T8205H Control Module is for use with heat pump systems only and has 1 4 in quick connect terminals Module controls within 1 5 F 0 8 C at setpoint of 106 F 41 C Models available for single control or dual control of combination pool and spa Isolated re...

Page 2: ...herefore this unit may not exactly match the listed specifications Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed Models T8205B C and TS8205B C Electronic Pool Spa and Hot Tub Control Systems provide single or dual water temperature control in pool spa or hot tub applications O...

Page 3: ...ntrol Modules mount on any flat surface using no 6 screws obtained locally through mounting holes Q8205A C Setpoint Panels mount through holes on board using no 6 screws obtained locally Sensing Bulb Can be mounted in immersion well or directly immersed using fittings to prevent leakage Well or fitting supplied by heater manufacturer Approvals International Approval Services American Gas Associati...

Page 4: ...8 2 1 8 54 3 76 5 16 8 5 8 16 1 1 8 29 2 3 4 70 5 1 8 130 5 1 8 130 5 8 16 1 5 8 41 1 31 32 50 1 31 32 50 2 5 8 67 3 76 3 76 1 1 8 29 1 13 16 46 1 5 16 33 COM POT 1 2 2 2 4 3 2 2 2 1 1 M11013B 1 2 3 4 THIS SECTION ON T8205B C MODELS ONLY 3 8 IN 10 MM RECOMMENDED FOR SHAFT CLEARANCE HOLE POTENTIOMETER SHAFT DIAMETER 24 IN 6 MM SWITCH SHAFT DIAMETER 25 IN 6 MM 3 4 19 1 1 4 32 1 1 4 32 1 1 4 32 3 4 1...

Page 5: ...r O ring and clamp to prevent leaks and keep the sensor leadwires dry Wells and fittings must be supplied by the heater manufacturer Control Systems IMPORTANT TS8205A Control Module and Q8205A C Setpoint Panels must be mounted to allow adequate electrical spacing according to approval agency requirements The T8205B C and TS8205B C Control Systems can be mounted on the appliance through mounting ho...

Page 6: ...FACTORY WIRED ON T8205B C 1 2 3 3 2 M11014B T8205B T8205A Q8205B Fig 4 T8205B C TS8205B C has similar wiring configuration wired to 24V gas control to control water temperature in pool spa or hot tub T8205B shown POT POT LOAD COM SEN SEN L1 HOT L2 1 SENSOR FUSE LIMIT S 24 VAC 24V HOT ONLY SWITCH POT POT POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED Q8205C HAS TWO POTENT...

Page 7: ...ications SETTINGS Select Control Temperature The control temperature is set by turning the setpoint potentiometer The limit of clockwise rotation with the shaft toward you represents the maximum 106 F 41 C setting Turning the potentiometer counterclockwise through its full rotation moves the setting to the minimum limit On models with two potentiometers one potentiometer is used to set the pool te...

Page 8: ...205A are used with the Q8205A C The T8205B C and the TS8205B C include the Q8205B C The setpoint potentio meter on the Q8205 is used to set the operating temperature On models with two potentiometers one is used to set the pool temperature and the other is used to set the spa temperature Relay contacts in the module close to turn on the gas control or ignition module when the temperature at the se...

Page 9: ...LEADS AND CHECK OUT SYSTEM TEMPERATURE BELOW 105 F 40 C DISCONNECT SENSOR LEADS FROM CONTROL MEASURE SENSOR RESISTANCE WITH OHMMETER CHECK VOLTAGE T8205 Q8205 24V TERMINALS TS8205 Q8205 AND TERMINALS VOLTAGE OUTSIDE RANGE T8205 Q8205 21 5 TO 28 5V CHECK TRANSFORMER AND 120V SUPPLY CORRECT AS NECESSARY TS8205 Q8205 0 2V TO 0 75V CHECK GENERATOR CORRECT AS NECESSARY RESISTANCE 0 ohms SHORT CIRCUIT C...

Page 10: ... ohms REPLACE SETPOINT PANEL 0 ohms SHORT CIRCUIT REPLACE SETPOINT PANEL RECONNECT ALL LEADS AND CHECK OUT SYSTEM TEMPERATURE ABOVE 106 F DISCONNECT SENSOR LEADS FROM CONTROL MEASURE SENSOR RESISTANCE WITH OHMMETER CHECK VOLTAGE T8205 Q8205 24V TERMINALS TS8205 Q8205 AND TERMINALS RESISTANCE ABOVE 15K ohms OPEN CIRCUIT FIX LOOSE OR BROKEN WIRES REPLACE SENSOR IF NECESSARY MEASURED AND ESTIMATED RE...

Page 11: ...T8205B C TS8205B C ELECTRONIC POOL SPA CONTROL SYSTEMS T8205A H TS8205A CONTROL MODULES Q8205A C SETPOINT PANELS AND SENSOR ASSEMBLY 68 0177 1 11 ...

Page 12: ...ywell Asia Pacific Inc Room 3213 3225 Sun Hung Kai Centre No 30 Harbour Road Wanchai Hong Kong Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Honeywell Latin American Revion 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Automation Control and Solutions Honeywell International Inc 1985 Douglas Drive Golden Valley MN 55422 68 0177 1 J S Rev 2 98 customer...