background image

I

I

n

n

t

t

e

e

l

l

l

l

i

i

P

P

a

a

t

t

h

h

T

T

M

M

 

 

S

S

e

e

r

r

i

i

e

e

s

s

 

 

4

4

G

G

 

 

G

G

S

S

M

M

 

 

C

C

o

o

m

m

m

m

u

u

n

n

i

i

c

c

a

a

t

t

o

o

r

r

 

 

A

A

u

u

t

t

o

o

-

-

s

s

e

e

l

l

e

e

c

c

t

t

s

s

 

 

O

O

p

p

t

t

i

i

m

m

u

u

m

m

 

 

G

G

S

S

M

M

 

 

p

p

a

a

t

t

h

h

 

 

 

 

2

2

G

G

,

,

 

 

3

3

G

G

,

,

 

 

o

o

r

r

 

 

4

4

G

G

 

 

G

G

S

S

M

M

X

X

4

4

G

G

 

 

/

/

 

 

G

G

S

S

M

M

X

X

C

C

N

N

4

4

G

G

 

 

s

s

u

u

p

p

p

p

o

o

r

r

t

t

s

s

 

 

t

t

w

w

o

o

-

-

w

w

a

a

y

y

 

 

v

v

o

o

i

i

c

c

e

e

 

 

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

a

a

n

n

d

d

 

 

S

S

e

e

t

t

u

u

p

p

 

 

G

G

u

u

i

i

d

d

e

e

 

 

 

 

 

REG

TX/RX

FAULT

SIGNAL

 

 

 

 

800-10938  1/12  Rev. B   

Summary of Contents for GSMX4G

Page 1: ... o s se el le ec ct ts s O Op pt ti im mu um m G GS SM M p pa at th h 2 2G G 3 3G G o or r 4 4G G G GS SM MX X4 4G G G GS SM MX XC CN N4 4G G s su up pp po or rt ts s t tw wo o w wa ay y v vo oi ic ce e I In ns st ta al ll la at ti io on n a an nd d S Se et tu up p G Gu ui id de e REG TX RX FAULT SIGNAL 800 10938 1 12 Rev B ...

Page 2: ...amming Conventions 12 Using the Control Panel 12 Programming for ECP Mode 12 Programming for 4204 and Two 4204 Emulation Modes 13 4204 Emulation Mode Options 13 Programming Options 14 ECP Status Codes 24 Exiting the Programming Mode 25 Setting Factory Defaults 25 Registering the Communicator 26 Registering through the AlarmNet Direct Website 26 Remote Services 27 Registering Using the Test Message...

Page 3: ... it will attempt to send a transmission via SMS Short Message Service also known as a text message In addition to alarm reporting the communicator provides two way voice communications with the central station when used with Honeywell s AVS Audio Verification System and provides upload downloading capability of Honeywell s control panel data over the Internet via the AlarmNet G network using GSM G...

Page 4: ...mmunicator detects a communication path failure the control panel can be notified of a trouble condition with the communicator after a specified time has elapsed Specifications Dimensions 4 x 7 x 1 75 inches Input Voltage 12VDC powered via the ECP bus Standby Current 65mA Active Current 380mA Operating temperature 20º to 55ºC for UL ULC installations 0ºC to 49ºC Storage temperature 40º to 70ºC Hum...

Page 5: ...h for Certification number 127 Remote Services Features UL Remote Access and Multi Mode have not been evaluated by UL Honeywell offers secure web based services that enable users to remotely monitor and control their security system These web services enable users to Monitor and control their security system from a website Receive e mail and text message notifications of system events Control the ...

Page 6: ...enna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter If the control panel location does not provide adequate signal strength then the communicator can be mounted remotely Activate the SIM NOTE The SIM in the communicator must be ACTIVATED fi...

Page 7: ...atisfactory signal strength You can power it from a 12V battery or from the control panels AUX PWR terminals In buildings where reception may be a problem powering from a battery would allow the communicator to be portable The following procedure assumes the control panel will be used for power If satisfactory signal strength is present at the control panel that is the preferred mounting location ...

Page 8: ... right of the control panel cabinet 2 Open the communicator cover Remove the Hole Cap attached to the plastic trim as necessary and snap it into the top opening of the enclosure 3 Remove the bottom knockout on the enclosure for the threaded mount Then install the threaded mount so it snaps into the plastic retaining tabs Mount the communicator assembly on the cabinet s knockout and fasten with the...

Page 9: ...e wiring 6 Secure the wiring with ties as necessary Wiring the Module for two way voice The GSMX4G requires an optional audio cable GSMX AUDIO black to support two way voice using the AVS Base Unit Note the AVS Base Unit is part of Honeywell s AVS Audio Verification System This system consist of the AVS Base Unit Remote Station and the Remote Station PC board For detailed information please refer ...

Page 10: ...wraps to reduce strain Mounting the Module on the Wall 1 Ensure control panel power both AC and battery is off then remove a suitable knockout on the top or side of the control panel cabinet NOTES If in the wall wiring will be used route the wiring through the communicator s rear wiring access hole If surface mounted wiring will be used remove the communicator s bottom knockout and use that to rou...

Page 11: ...binet the length of the sup plied ECP cable will have to be spliced to a four wire extender cable Ensure the splices are located within the communicator s enclosure Use the table below to determine the minimum wire gauge for the extender cable Minimum Wire Gauge Distance from Control Panel 22 75 ft 23m 20 120 ft 37m 18 170 ft 52m 16 270 ft 82m 5 Route the wires through the rear wiring access hole ...

Page 12: ...ing NOTE The prompts in this document reflect use of the 7720P Program ming Tool Using the AlarmNet Direct Website To program the communicator via the website if you are already signed up for this service go to https services alarmnet com AlarmNetDirect If you are not signed up for this service click on Dealer Sign Up and follow the instructions Log in and follow the on screen prompts Please have ...

Page 13: ...o can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO answer Y Press for YES answer SHIFT Press before pressing a SHIFT key function Will light SHIFT LED LED goes out once a key is pressed Press again for each SHIFT function desired 1 A 1 For entering the number 1 A For entering letter A 2 B 2 For entering the number 2 B For entering letter B 3 C 3 For e...

Page 14: ...rrow keys to scroll through the programming prompts without changing any values Press the ESC key to go to the end of the list of prompts Using the Control Panel Some control panels support programming of the communicator through the control panel programming mode If using this method of programming only the ECP Mode programming options are available Other mode prompts will not be displayed and th...

Page 15: ...or two 4204 relay modules accordingly On VISTA 32FB or higher control panels and First Alert equivalents addresses 6 and 13 should not be used when the secondary 4204 is enabled Messages are sent in ADEMCO High Speed format See your control panel Installation and Setup Guide for the number of 4204 modules supported 4204 Emulation Mode Options For control panels that do not support ECP communicatio...

Page 16: ...n others it is called output device programming It is recommended that close and stay closed usually choice 2 action is selected Selection of momentary activation will cause the communicator to generate an alarm and NOT a restore even if the communicator is pro grammed to send a restore for the given zone In 4204 mode messages are reported in ADEMCO High Speed format Zone alarms status 7 are repor...

Page 17: ...password has been assigned this prompt appears after pressing N at the Program Device prompt If a password is desired press Y and go to Prompt 6 Enter Password 5 Change Password Y N _ Y N If a password has already been assigned this prompt appears after pressing N at the Program Device prompt Press Y if you want to change the password NOTE To clear an existing password without entering a new one a...

Page 18: ...the Exit Prog Mode prompt Verify Not OK PSWD not created Otherwise the Exit Prog Mode prompt is displayed directly 8 Exit Prog Mode Y N _ Y N ESC Exits program mode Press N to go back to Prompt 3 Press ESC to load factory defaults Refer to the Exiting the Programming Mode topic 9 Device Mode ECP _ ECP 4204 Emu Two 4204s Press the space key to scroll through the modes of operation Press ENTER to se...

Page 19: ...onnect website and must correspond to outputs relays programmed in the control panel through Output Device programming The Multi Mode address selected at prompt 11 in the communicator or at the AlarmNet Direct website must match the address of a 4204 relay module enabled in the control panel although you don t actually connect a module If using 2 4204 sourced the address of the second module is au...

Page 20: ... Category Enable reporting for the communicator or LRR device e g VISTA 128BP FA1660C etc Used if reporting to a second central station is desired 16 Device Address 03 _ 01 30 The GSMX4G communicates with the control panel as a commu nicator or LRR device Enter the ECP device address NOTE When programming the control panel enable the commu nicator s or LRR output Setting up the Remote Access Featu...

Page 21: ...etwork must hear at least one supervisory message from the communicator during this supervision period otherwise AlarmNet notifies the central station that a communica tion failure has occurred If the supervision period is changed after registration you must re register the communicator Press the space key to scroll through choices UL ULC NOTE Must be 24 hour 20 Old Alarm Time 10 Minutes _ 10 Minu...

Page 22: ... minute 22 Telco Zone 0 _ only 4204 2 4204 4204 1 4 2 4204 1 8 0 not used See Important Information Regarding Zone Input Options on previous page Enter the zone number to be used for Telco line fault reports This zone assignment must be unique from the open close zone selected in Prompt 23 4204 Mode If any zone is programmed for report only if armed zone 4 cannot be used as a Telco zone 2 4204 Mod...

Page 23: ...sed NOTE Connect an open close arm disarm trigger or relay output from the control panel to the open close zone 24 Restore Zn1 Y N Y only 4204 2 4204 Y N Enables restore reporting for zone 1 25 Delay Zn1 secs 00 only 4204 2 4204 01 15 00 no delay Defines the reporting delay in seconds for zone 1 26 Rpt Zn1 ONLY if Armed N only 4204 2 4204 Y N Reports alarms on zone 1 ONLY if the conditional zone z...

Page 24: ...one 3 32 Rpt Zn3 ONLY if Armed N only 4204 2 4204 Y N Reports alarms on zone 3 ONLY if the conditional zone zone 4 in 4204 mode or zone 8 in 2 4204 mode is triggered armed If N always reports alarms on zone 3 33 Restore Zn4 Y N Y only 4204 2 4204 Y N Enables restore reporting for zone 4 34 Delay Zn4 secs 00 only 4204 2 4204 01 15 00 no delay Defines the reporting delay in seconds for zone 4 35 Rpt...

Page 25: ...y Zn6 secs 00 only 2 4204 01 15 00 no delay Defines the reporting delay in seconds for zone 6 41 Rpt Zn6 ONLY if Armed N only 2 4204 Y N Reports alarms on zone 6 ONLY if the conditional zone zone 4 in 4204 mode or zone 8 in 2 4204 mode is triggered armed If N always reports alarms on zone 6 42 Restore Zn7 Y N Y only 2 4204 Y N Enables restore reporting for zone 7 43 Delay Zn7 secs 00 only 2 4204 0...

Page 26: ...in the correct value When the last field is displayed the REVIEW prompt again appears To exit the programming mode press N in response to the REVIEW prompt and refer to Exiting Programming Mode topic ECP Status Codes The communicator sends status messages to the control panel to report various failures Some control panels e g VISTA 10P VISTA 15P and VISTA 20P Series display these status codes on t...

Page 27: ...de of operation the communicator will reset to ensure that the programming features are enabled If the file is not successfully uploaded one of the following prompts will be displayed Follow the steps shown below until the upload is successful Display Description What to do Cannot Upload Try Again Y N_ GSM Communicator has not yet initialized Wait for SIGNAL green LED to be lit Press Y Failed to U...

Page 28: ...oes out and the TX RX yellow LED is lit to indicate that the power on reset message is waiting to be sent This message will appear at the receiving station as E339 803 The description may read Trouble Exp Mod Reset If registration is not validated within 90 seconds the communicator times out and the REG green LED will be lit solid Registering through the AlarmNet Direct Website To register the com...

Page 29: ...b account for the customer For TC1 compatible communicators 4204 Multi Mode must be used For TC2 compatible communicators Enhanced Reports must be enabled Once the dealer assigns a login name and password the customer will receive a Welcome e mail message with their login name along with some helpful information The customer will receive another e mail message with their password They will then be...

Page 30: ...ssible Errors Registration BAD Timed Out Displayed if no response to the registration request is received Registration BAD Pri Sub ID BAD Indicates the city central station or customer number for the labeled account s is not accepted The ID information was either entered in error or the central station failed to pre authorize programmed ID numbers with AlarmNet customer service Registration BAD Pr...

Page 31: ...t wording The registration process is repeated NOTE Each attempt causes a substitution alarm to be sent to the central station Registering by Phone You can register the communicator by calling the AlarmNet Support at 1 800 222 6525 Option 1 Monday Friday 8 00 am to 9 00 pm Saturday 9 00 am to 5 30 pm EST You will need the following information MAC ID and CRC located on the box and inside the commu...

Page 32: ...on the box and inside the communicator Press the Space key to go to the next field Press the BS key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this device Press the Space key to go to the next field Press the BS key to go to the previous field IMEI xxxxxxxx xxxxxx x IMEI Display Displays the identificati...

Page 33: ...red Roaming Unknown Registration State Press the space key to go to the next screen Press the backspace key to go to the last screen RAT EC NO 3G 4G xxxxx Status Display Screen 2 RAT Radio Access Technology EC NO Carrier Noise Ratio CNR Press the space key to get to the next screen Press the backspace key to go to the previous field CNtry NetW LAC xxx xxx xxxxx Status Display Screen 3 CNtry Countr...

Page 34: ...mary site level in dBm 2G Communicator is on the 2G network where stat can be Good RSSI 20 to 89 dBm OK RSSI 90 to 98 dBm Marginal RSSI 99 to 104 dBm Bad RSSI 105 to 150 dBm REG Registration status where x can be N Not Registered H Registered Home S Searching D Registration Denied R Registered Roaming Unknown Registration State Press the space key to go to the next screen Press the backspace key t...

Page 35: ...ndary Site RSSI availability Available or Not Available will be displayed Press the space key to go to Status Display Screen 1 Press the backspace key to go to the previous field S ECP Flt OK ECP Mode Displays the mode of operation and system fault status Flt Represents communicator faults OK Normal No fault G No network connectivity over GSM and fault time has expired g No network connectivity ov...

Page 36: ...e displayed Cannot Upload Try Later _ 0 Force Server Update Y N Wait for the SIGNAL green LED to light indicating the communicator has completed its initialization and try again ENTER Strt Prog Mode Y N_ Enter Program Mode Press Y to enter program mode otherwise press N Central Station Messages The following messages are sent to the Central Station by AlarmNet for the conditions listed below NOTE ...

Page 37: ...ds 4G provides up to 10 times the data transfer speeds of 3G AES Advanced Encryption Standard CRC Cyclic Redundancy Check used to confirm validity of MAC ID ECP Enhanced Console Protocol is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices It uses four wires power ground data in data out GPRS General Packet Radio Service GSM Global System for Mob...

Page 38: ...Notes ...

Page 39: ...n in progress FAULT red ON No contact with network OFF Normal SLOW BLINK Loss of communication with the panel ECP fault FAST BLINK No network contact AND loss of communication with the control panel SIGNAL green ON Minimum required signal strength is present BLINKING Marginal signal strength is present OFF Installation is not recommended ALL FAST BLINK Hardware Error GSMX4G 010 V0 REG TX RX FAULT ...

Page 40: ...ient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio TV technician f...

Reviews: